Columbia County is committed to ensuring accessibility to this website regardless of disability. If anyone encounters a feature on this website that is inaccessible due to a disability, please contact the County Manger’s Office and the Columbia County Board of County Commissioners at (386) 758-1005. You may also email that office at patrick_weaver@columbiacountyfla.com and provide a brief description of the inaccessible feature. The County will either correct the inaccessible feature or, if correction is not possible due to technical limitations, provide the desired information through alternative means.

Skip to content

Columbia County, FL | Permit Details

New Residential Construction Permit

Address 284 SW THISTLEWOOD LN
FORT WHITE, FL 32038
Parcel #: 04056-123
Acres: 1.10
Owner: Terry Craig A, Terry Lisa
Subdivision: Thornwood
Zoning:
Flood Zone: X
District: 2
Application #: 66807
Permit #: 000051696
Related Permit: Right-of-Way Access/Driveway: 000051687
Submitted: Tuesday, August 27, 2024
Issued: Tuesday, December 3, 2024
Expires: Tuesday, April 15, 2025
Completed: Tuesday, April 15, 2025
Status: Completed
Septic Release? Yes
Notes:
FINISHED FLOOR 12 INCHES ABOVE GRADE FOR THE ENTIRE PERIMITER PERIMETER OF THE FOUNDATION
Job Details
Elevation regulation Engineers Elevation Letter
Finished floor requirement 12 inches above grade for entire perimiter
Document receieved Yes
Fema map number 12023C0490C
This is the construction of a Single Family Dwelling
Setbacks Front 30'
Setback Side 1 25'
Setback Side 2 25'
Setbacks Rear 25'
Stories 1
Heated Area (Sqft) 1843
Total Area (Sqft) 2716
Building Height 20
Building Code Construction Type V
Building Code Element B
Building Code Occupancy Types Residential
Occupancy Use Title single family residence
Building Code Edition 2023 Florida Building Code 8th Edition and 2020 National Electrical Code
Septic# (00-0000) or (X00-000) 24-0717
Sealed roof decking options. (Must select one option per FBC 2023 8th Edition) two layers of felt underlayment comply ASTM 0226 Type II or ASTM D4869 Type Ill or IV, or two layers of a synthetic underlayment meeting the performance requirements specified, lapped and fastened as specified.
Service Amps 200
Review Notes
8/26/2024 Application pending.
8/27/2024 Application submitted by applicant.
8/28/2024 Point Review - On Hold-Incomplete
9/13/2024 Point Review - On Hold-Incomplete
11/19/2024 Point Review - Printed-Online Application
12/3/2024 Zoning Review - Reviewed
12/3/2024 Plan Review - Documents Required
12/3/2024 Plan Review - Plumbing Approved
12/3/2024 Plan Review - Mechanical Approved
12/3/2024 Plan Review - Electrical Approved
12/3/2024 Plan Review - Building Approved
12/3/2024 Plan Review - Reviewed
12/3/2024 Final Review - Processing
12/3/2024 Zoning Review - Town of Ft. White
12/3/2024 Final Review - Payment Needed
12/3/2024 Permit Issued
Contractors
Name/ Business License Title Role
Jeffrey P Bokor
Dwc Contracting Llc
Workers Comp Expired.
CGC1517145 General Contractor Contractor
James Butler Jr
Butler Plumbing Of Gainesville Inc
Workers Comp Expired.
CFC057960 Plumbing Contractor Subcontractor
Jeffrey Bokor
Dwc Contracting Llc
Workers Comp Expired.
CCC1329756 Roofing Contractor Subcontractor
Ryan C Beville
Rbi Electrical Contracting Llc
EC13004236 Electrical Contractor Subcontractor
Samuel L Roberts
Air Ducks Inc
Liability Insurance Expired.
CAC1817288 Class "b" A/c Subcontractor
Inspections
Inspection Notes Performed By Date
Passed: Plumbing/Gas - 1st Underground Rough–In Anthony Aslan 12/5/2024
Passed: Building - Monolithic Slab Anthony Aslan 12/16/2024
Passed: Engineering - Setbacks Anthony Aslan 12/16/2024
Passed: Building - Ext Strapping/Wall Sheathing Anthony Aslan 12/27/2024
Passed: Building - Roof Decking Anthony Aslan 12/27/2024
Passed: Building - Framing Anthony Aslan 1/8/2025
Passed: Electrical - 2nd Rough-In Anthony Aslan 1/8/2025
Passed: Plumbing/Gas - 2nd Rough-In Anthony Aslan 1/8/2025
Failed: Plumbing/Gas - Tub Set/Shower Pan No Tube Or Pans Installed Anthony Aslan 1/8/2025
Failed: Mechanical - Rough In No Screws In Kitchen Exhaust no Hanging Straps On Exhaust Venting Anthony Aslan 1/16/2025
Passed: Building - Insulation Walls Only Anthony Aslan 1/21/2025
Passed: Mechanical - Rough In Corrections Made Anthony Aslan 1/21/2025
Septic Release Inspection Health Dept 2/27/2025
Passed: Electrical - Permanent Power Troy Crews 3/4/2025
Release to power company Final Drive Rec'd Troy Crews 3/4/2025
Cancelled: Plumbing/Gas - Tub Set/Shower Pan Anthony Aslan 4/9/2025
Cancelled: Plumbing/Gas - Water Pipe Anthony Aslan 4/14/2025
Passed: Plumbing/Gas - Tub Set/Shower Pan Anthony Aslan 4/14/2025
Passed: Building - Final Cannot Closed Permit Or Release Certificate Of Occupancy Due To Missing Required Documents. Anthony Aslan 4/14/2025
Certificate-Release Certificate Anthony Aslan 4/15/2025
Documents
File Name Date File Size