Columbia County is committed to ensuring accessibility to this website regardless of disability. If anyone encounters a feature on this website that is inaccessible due to a disability, please contact the County Manger’s Office and the Columbia County Board of County Commissioners at (386) 758-1005. You may also email that office at patrick_weaver@columbiacountyfla.com and provide a brief description of the inaccessible feature. The County will either correct the inaccessible feature or, if correction is not possible due to technical limitations, provide the desired information through alternative means.

Skip to content

Columbia County, FL | Permit Details

Roof Replacement or Repair Permit
Address 1214 SW WALTER AVE
LAKE CITY, FL 32024
Parcel #: 03437-003
Acres: 9.99
Owner: Smith Walter G
Subdivision:
Zoning: A-3
Flood Zone: X
District: 5
Application #: 68359
Permit #: 000051673
Related Permit:
Submitted: Wednesday, November 27, 2024
Issued: Monday, December 2, 2024
Expires: Thursday, February 20, 2025
Completed: Thursday, February 20, 2025
Status: Completed
Septic Release? na
Notes:

Job Details
Type Roofing Job Replacement - Tear off Existing and Replace
Type of structure House
Commercial or Residential Residential
Roof Area (for this job) Sq Ft 50
No. of Stories 1
Ventilation: Ridge Vent
Flashing: Use Existing
Drip Edge: Replace All
Valley Treatment: New Metal
Roof Pitch 4:12 or Greater
Any cable and/or race-way wiring located on or within the roof assembly? No
Is the existing roof being removed? Yes
Type of New Roofing Product Asphalt Shingles
Florida Product Approval Number FL10674-R19
Product Manufacturer Owens Corning Asphalt Roof Shingles
Product Description Asphalt Shingles
Sealed roof decking options: (Must select an option.) a minimum 4-inch wide strip of selfadhering polymer-modified bitumen complying with ASTM D1970 or a minimum 3 ¾ - inch wide strip of selfadhering flexible flashing tape complying with AAMA 711, applied over all joints in the roof decking. A felt underlayment complying with ASTM D226 Type II, ASTM D4869 Type Ill or IV, or ASTM D6757, or a synthetic underlayment meeting the performance requirements specified, is required to be applied over the strips/tape over the entire roof.
Building Code Edition 2023 Florida Building Code 8th Edition and 2020 National Electrical Code
Fema map number 12023C0383D
Review Notes
11/26/2024 Application pending.
11/27/2024 Application submitted by applicant.
12/2/2024 Final Review - Corrections Needed NEEDED * OWNERS PHONE NUMBER - EMAIL BLDGINFO@COLUMBIACOUNTYFLA.COM ONCE THIS HAS BEEN CORRECTED
12/2/2024 Final Review - Payment Needed
12/2/2024 Permit Issued Permit #000051673 created and approved.
2/18/2025 Final Review - Complete INPROGRESS AND FINAL INSPECTIONS NEEDS TO BE DONE
Contractors
Name/ Business License Title Role
Tyler M Turner
Tmt Roofing Llc
CCC1330410 Cert Roofing Contractor
Inspections
Inspection Notes Performed By Date
Cancelled: Re-Roof - In Progress Troy Crews 2/18/2025
Passed: Re-Roof - In Progress Was Inspected On 2/12/25 With Garage Gary Pitzer 2/19/2025
Passed: Re-Roof - Final Gary Pitzer 2/20/2025