Columbia County is committed to ensuring accessibility to this website regardless of disability. If anyone encounters a feature on this website that is inaccessible due to a disability, please contact the County Manger’s Office and the Columbia County Board of County Commissioners at (386) 758-1005. You may also email that office at patrick_weaver@columbiacountyfla.com and provide a brief description of the inaccessible feature. The County will either correct the inaccessible feature or, if correction is not possible due to technical limitations, provide the desired information through alternative means.

Skip to content

Columbia County, FL | Permit Details

Roof Replacement or Repair Permit
Address 174 SW MORNING STAR GLN
FORT WHITE, FL 32038
Parcel #: 03752-121
Acres: 10.01
Owner: Celebration Community Church Of Southern Columbia County
Subdivision: Shanna Meadows
Zoning: A-3
Flood Zone: X
District: 4
Application #: 68375
Permit #: 000051670
Related Permit:
Submitted: Wednesday, November 27, 2024
Issued: Monday, December 2, 2024
Expires: Thursday, February 6, 2025
Completed: Thursday, February 6, 2025
Status: Completed
Septic Release? na
Notes:

Job Details
Type Roofing Job Overlay with Metal
Type of structure Commercial Building
Commercial or Residential Commercial
Roof Area (for this job) Sq Ft 106
No. of Stories 1
Ventilation: Ridge Vent
Flashing: Use Existing
Drip Edge: Replace All
Valley Treatment: New Metal
Roof Pitch 4:12 or Greater
Any cable and/or race-way wiring located on or within the roof assembly? No
Is the existing roof being removed? No
Explain if not removing the existing roofing material? Metal overlay
Type of New Roofing Product Metal
Florida Product Approval Number 17992.1
Product Manufacturer Capital Metal Supply
Product Description Min. 29 Ga. Capital Rib Roof Panel over 1x4 Wood Purlins over 7/16” OSB
Sealed roof decking options: (Must select an option.) a minimum 4-inch wide strip of selfadhering polymer-modified bitumen complying with ASTM D1970 or a minimum 3 ¾ - inch wide strip of selfadhering flexible flashing tape complying with AAMA 711, applied over all joints in the roof decking. A felt underlayment complying with ASTM D226 Type II, ASTM D4869 Type Ill or IV, or ASTM D6757, or a synthetic underlayment meeting the performance requirements specified, is required to be applied over the strips/tape over the entire roof.
Building Code Edition 2023 Florida Building Code 8th Edition and 2020 National Electrical Code
Fema map number 12023C0390C
Review Notes
11/27/2024 Application pending.
11/27/2024 Application submitted by applicant.
12/2/2024 Final Review - Corrections Needed NEEDED * OWNERS PHONE NUMBER - EMAIL BLDGINFO@COLUMBIACOUNTYFLA.COM ONCE CORRECTED
12/2/2024 Final Review - Payment Needed
12/2/2024 Permit Issued Permit # created and approved from payment.
Contractors
Name/ Business License Title Role
Tyler M Turner
Tmt Roofing Llc
CCC1330410 Cert Roofing Contractor
Inspections
Inspection Notes Performed By Date
Passed: Re-Roof - In Progress Troy Crews 1/23/2025
Passed: Re-Roof - Final Troy Crews 2/6/2025