Permit Details

Permit Search

Permit

Roof Replacement or Repair

692 NW INDIAN SPRINGS DR
LAKE CITY, FL 32055

Permit #
000051641
Application #
68324
Status Completed
  1. Submitted Nov 25, 2024
  2. Issued Nov 25, 2024
  3. Expires Aug 4, 2025
  4. Completed Feb 5, 2025

Property

Parcel #
00167-014
Owner
Kaptain Peter D
Acres
5.05
Subdivision
Oakhaven
Zoning
A-3
Flood zone
X
District
3

Permit

Status
Completed
Septic release
N/A
Related permit
—

Job Details

Finished floor requirement
Fema map number
12023C0260C
Type Roofing Job
Replacement - Tear off Existing and Replace
Type of structure
House
Commercial or Residential
Residential
Roof Area (for this job) Sq Ft
54
No. of Stories
2
Roof Pitch
4:12 or Greater
Is the existing roof being removed?
Yes
Type of New Roofing Product
Asphalt Shingles
Florida Product Approval Number
18355.1
Product Manufacturer
TAMKO Asphalt Shingles
Product Description
ASTM D3462 asphalt shingles and hip and ridge shingles
Building Code Edition
2023 Florida Building Code 8th Edition and 2020 National Electrical Code
Sealed roof decking options: (Must select an option.)
a minimum 4-inch wide strip of selfadhering polymer-modified bitumen complying with ASTM D1970 or a minimum 3 ¾ - inch wide strip of selfadhering flexible flashing tape complying with AAMA 711, applied over all joints in the roof decking. A felt underlayment complying with ASTM D226 Type II, ASTM D4869 Type Ill or IV, or ASTM D6757, or a synthetic underlayment meeting the performance requirements specified, is required to be applied over the strips/tape over the entire roof.
Ventilation:
Ridge Vent
Flashing:
Use Existing
Drip Edge:
Replace All
Valley Treatment:
New Metal
Any cable and/or race-way wiring located on or within the roof assembly?
No

Status & Review History

  1. Application pending.
  2. Application submitted by applicant.
  3. Final Review - Payment Needed
  4. Permit Issued

Contractors

No contractors are listed on this permit.

Inspections

  1. Jan 28, 2025

    Passed: Re-Roof - In Progress

    Inspected by Matt Forsyth

  2. Feb 5, 2025

    Passed: Re-Roof - Final

    Inspected by Matt Forsyth