Columbia County is committed to ensuring accessibility to this website regardless of disability. If anyone encounters a feature on this website that is inaccessible due to a disability, please contact the County Manger’s Office and the Columbia County Board of County Commissioners at (386) 758-1005. You may also email that office at patrick_weaver@columbiacountyfla.com and provide a brief description of the inaccessible feature. The County will either correct the inaccessible feature or, if correction is not possible due to technical limitations, provide the desired information through alternative means.

Skip to content

Columbia County, FL | Permit Details

New Residential Construction Permit
Address 370 SW ROSEMARY DR
LAKE CITY, FL 32024
Parcel #: 02731-001
Acres: 0.22
Owner: Adams Homes Of Northwest Florida, Inc,
Subdivision: Preserve At Laurel Lake Unit 1
Zoning: PRD
Flood Zone: X
District: 3
Application #: 67214
Permit #: 000051632
Related Permit:
Submitted: Wednesday, October 2, 2024
Issued: Monday, November 25, 2024
Expires: Saturday, September 6, 2025
Completed:
Status: Permit Issued
Septic Release? Yes
Notes:
*SURVEYOR TO CONFIRM FRONT AND SIDE SETBACKS **SETBACKS CONFIRMATION RECEIVED ***ELEVATION CONFIRMATION REC'D @ 116.12' *CITY TAP INSPECTION REQUIRED PRIOR TO FINAL-- REQUEST THROUGH COUNTY
LAKE CITY UTLITY CUSTOMER SERVICE NOTES 10/29/24 The City of Lake City's Utility Department approved a tap application for water and sewer services. Locates must be obtained to ensure that the existing utility infrastructure is not damaged or obstructed.
Job Details
This is the construction of a Single Family Dwelling
Heated Area (Sqft) 1816
Total Area (Sqft) 2484
Stories 1
Building Height 18.0
Building Code Construction Type V
Building Code Element B
Building Code Occupancy Types Residential
Occupancy Use Title single family dwelling
Setbacks Front 25'
Setback Side 1 10'
Setback Side 2 10'
Setbacks Rear 15'
Septic# (00-0000) or (X00-000) x-city
Service Amps 200
Building Code Edition 2023 Florida Building Code 8th Edition and 2020 National Electrical Code
Elevation regulation Engineers Elevation Letter
Finished floor requirement 115.8'
Requirement needed By Nailing Inspection
Document needed is a Surveyor letter giving the Finished Floor Elevation
Document receieved Yes
Fema map number 12023C0290D
Sealed roof decking options. (Must select one option per FBC 2023 8th Edition) two layers of felt underlayment comply ASTM 0226 Type II or ASTM D4869 Type Ill or IV, or two layers of a synthetic underlayment meeting the performance requirements specified, lapped and fastened as specified.
Review Notes
9/25/2024 Application pending.
10/2/2024 City of Lake City Utilities Notified. City of Lake City Notified of Application within Utility Service Areas LC_GAS, LC_WATER, LC_SEWER.
10/25/2024 Application submitted by applicant.
10/25/2024 City of Lake City Utilities Notified. City of Lake City Notified of Application within Utility Service Areas LC_GAS, LC_WATER, LC_SEWER.
10/25/2024 Point Review - Printed-Online Application NEEDED: *SETBACKS SHOULD BE SITE PLAN SETBACKS, NOT MINIMUM SETBACKS, PLEASE CORRECT *DIGITAL SEAL INVALID, UPLOAD OR EMAIL TO BLDGINFO@COLUMBIACOUNTYFLA.COM, INCLUDE APP # *RESIDENTIAL CHECKLIST *TOTAL ESTIMATED COST
10/25/2024 Point Review - Reviewed NEEDED: *SETBACKS SHOULD BE SITE PLAN SETBACKS, NOT MINIMUM SETBACKS, PLEASE CORRECT *DIGITAL SEAL INVALID, UPLOAD OR EMAIL TO BLDGINFO@COLUMBIACOUNTYFLA.COM, INCLUDE APP # *RESIDENTIAL CHECKLIST *TOTAL ESTIMATED COST
10/25/2024 Zoning Review - Reviewed NEEDED: *SETBACKS SHOULD BE SITE PLAN SETBACKS, NOT MINIMUM SETBACKS, PLEASE CORRECT *DIGITAL SEAL INVALID, UPLOAD OR EMAIL TO BLDGINFO@COLUMBIACOUNTYFLA.COM, INCLUDE APP # *RESIDENTIAL CHECKLIST *TOTAL ESTIMATED COST
10/29/2024 Plan Review - Building Approved NEEDED: *SETBACKS SHOULD BE SITE PLAN SETBACKS, NOT MINIMUM SETBACKS, PLEASE CORRECT
10/29/2024 Plan Review - Electrical Approved NEEDED: *SETBACKS SHOULD BE SITE PLAN SETBACKS, NOT MINIMUM SETBACKS, PLEASE CORRECT
10/29/2024 Plan Review - Mechanical Approved NEEDED: *SETBACKS SHOULD BE SITE PLAN SETBACKS, NOT MINIMUM SETBACKS, PLEASE CORRECT
10/29/2024 Plan Review - Plumbing Approved NEEDED: *SETBACKS SHOULD BE SITE PLAN SETBACKS, NOT MINIMUM SETBACKS, PLEASE CORRECT
10/29/2024 Plan Review - Fuel/Gas Approved NEEDED: *SETBACKS SHOULD BE SITE PLAN SETBACKS, NOT MINIMUM SETBACKS, PLEASE CORRECT
10/29/2024 Plan Review - Reviewed NEEDED: *SETBACKS SHOULD BE SITE PLAN SETBACKS, NOT MINIMUM SETBACKS, PLEASE CORRECT
11/13/2024 Final Review - Reviewed
11/22/2024 Final Review - Payment Needed
11/25/2024 Permit Issued Permit #000051632 created and approved.
Contractors
Name/ Business License Title Role
William Adams
Adams Homes Of Northwest Florida Inc
CRC1330146 Cert. Residential Contractor
Shawn I Reynolds
N.c.f Electrical Services Llc
EC13011480 Cert. Electrical Subcontractor
Derrick L Williams
D L Williams Heating & Cooling Llc
CAC1816913 Class "b" A/c Contractor Subcontractor
Cody Barrs
Barrs Plumbing Inc
CFC1427145 Plumbing Contractor Subcontractor
Benjamin T Keeler
Keeler Roofing, Llc
CCC1330509 Cert. Roofing Subcontractor
Inspections
Inspection Notes Performed By Date
Passed: Plumbing/Gas - 1st Underground Rough–In Troy Crews 1/9/2025
Passed: Building - Monolithic Slab Troy Crews 1/13/2025
Passed: Engineering - Setbacks Surveyor To Confirm Setbacks Troy Crews 1/13/2025
Cancelled: Building - Slab Troy Crews 1/31/2025
Passed: Building - Ext Strapping/Wall Sheathing Troy Crews 2/4/2025
Passed: Building - Strapping Send Picture Nails In Strap Right Side Garage Opening. Troy Crews 2/4/2025
Passed: Building - Wall Sheathing Troy Crews 2/4/2025
Failed: Plumbing/Gas - 2nd Rough-In No Pressure Plumbing Troy Crews 2/4/2025
Passed: Building - Framing Troy Crews 2/4/2025
Passed: Mechanical - Rough In Troy Crews 2/4/2025
Passed: Electrical - 2nd Rough-In Troy Crews 2/4/2025
Passed: Plumbing/Gas - Tub Set/Shower Pan Troy Crews 2/4/2025
Passed: Building - Insulation Troy Crews 2/11/2025
Passed: Plumbing/Gas - 2nd Rough-In Pressure Applied. Troy Crews 2/11/2025
Release to power company Troy Crews 3/10/2025
Passed: Electrical - Permanent Power X-city Troy Crews 3/10/2025
Submitted Power Release through FPL Portal Garber, Melissa 3/10/2025
(Requested) Electrical -Permanent Power
Documents
File Name Date File Size
Power Release-release To Power Company 20250310.pdf 2025.03.10 38.96kB
City Of Lake City Accessibility Letter.pdf 2025.03.05 185.51kB
Letter 20250206 083050.pdf 2025.02.06 259.53kB
Surveyor Letter Confirming Mfe Requirements Are Met.pdf 2025.01.31 114.79kB
Engineer Elevation Requirement Letter.pdf 2025.01.31 399.59kB
Original Permit 20241125.pdf 2024.11.25 46.73kB
Srwmd Enhanced Snapshot 67214.pdf 2024.11.13 423.84kB
Floodplain Ordinance Notice To Owner 20241108 160224.pdf 2024.11.08 86.46kB
Reviewed Energy Code Forms 67214 2024-10-29 09.10.34.748.pdf 2024.10.29 190.89kB
Reviewed Manual J Forms 67214 2024-10-29 09.10.34.307.pdf 2024.10.29 1.07MB
Reviewed Sealed Plans 67214 2024-10-29 09.10.31.372.pdf 2024.10.29 11.83MB
Reviewed Truss Engineering 67214 2024-10-29 09.10.30.798.pdf 2024.10.29 1.71MB
Reviewed Architectural Plans 67214 2024-10-29 09.10.27.824.pdf 2024.10.29 11.91MB
Residential Or Commercial Checklist 20241028 080149.pdf 2024.10.28 370.24kB
Elevation Map 67214.pdf 2024.10.25 92.55kB
Preserve_at_laurel_lake_ut1 Lot 1.pdf 2024.10.25 5.93MB
Recorded Deed.pdf 2024.10.25 70.30kB
370 Sw Rosemary Dr.pdf 2024.10.25 871.57kB
Site Plan 20241018 102043.pdf 2024.10.18 417.31kB
Property Appraiser Parcel Details Printed Page 20240925 100716.pdf 2024.09.25 1.36MB
Contractor Letter Of Authorization 20240925 100122.pdf 2024.09.25 58.55kB
City Of Lake City Accessibility Letter 20240925 095936.pdf 2024.09.25 36.67kB
Subcontractor Form 20240925 095040.pdf 2024.09.25 121.70kB
Recorded Notice Of Commencement 20240925 095039.pdf 2024.09.25 52.41kB
Product Approval Code Specifications Form 20240925 095038.pdf 2024.09.25 187.78kB
Owner And Contractor Signature Page 20240925 093735.pdf 2024.09.25 74.52kB