Columbia County is committed to ensuring accessibility to this website regardless of disability. If anyone encounters a feature on this website that is inaccessible due to a disability, please contact the County Manger’s Office and the Columbia County Board of County Commissioners at (386) 758-1005. You may also email that office at patrick_weaver@columbiacountyfla.com and provide a brief description of the inaccessible feature. The County will either correct the inaccessible feature or, if correction is not possible due to technical limitations, provide the desired information through alternative means.

Skip to content

Columbia County, FL | Permit Details

Roof Replacement or Repair Permit
Address 400 NW HORIZON ST
LAKE CITY, FL 32055
Parcel #: 02374-083
Acres: 2.97
Owner: Lunde Blake N Ii, Lunde Stephanie E
Subdivision:
Zoning: RSF-2
Flood Zone: X
District: 3
Application #: 66166
Permit #: 000051598
Related Permit:
Submitted: Thursday, November 21, 2024
Issued: Thursday, November 21, 2024
Expires: Monday, February 24, 2025
Completed: Monday, February 24, 2025
Status: Completed
Septic Release? na
Notes:

Job Details
Type Roofing Job Partial Roof Repairs
Further Job Details (Explain if decking is being replaced and or Repairs are being done.) Replacing 45% of existing roof installed in 2005
Type of structure House
Commercial or Residential Residential
Roof Area (for this job) Sq Ft 2854
No. of Stories 1
Ventilation: Unvented
Flashing: Replace All
Drip Edge: Replace All
Valley Treatment: New Metal
Roof Pitch 4:12 or Greater
Any cable and/or race-way wiring located on or within the roof assembly? No
Is the existing roof being removed? Yes
Explain if not removing the existing roofing material? Addition was installed in 2012 Not being replaced
Type of New Roofing Product Metal
Florida Product Approval Number FL36904.2
Product Manufacturer Tri County Metals
Product Description Ultra Rib 29 GA
Sealed roof decking options: (Must select an option.) two layers of felt underlayment comply ASTM 0226 Type II or ASTM D4869 Type Ill or IV, or two layers of a synthetic underlayment meeting the performance requirements specified, lapped and fastened as specified.
Building Code Edition 2023 Florida Building Code 8th Edition and 2020 National Electrical Code
Fema map number 12023C0280D
Review Notes
7/10/2024 Application pending.
11/21/2024 Application submitted by applicant.
11/21/2024 Final Review - Payment Needed
11/21/2024 Permit Issued Permit # created and approved from payment.
Contractors
Name/ Business License Title Role
Blake N Lunde Ii
Blake Roofing Inc
Liability Insurance Expired.
CCC1331699 Cert. Roofing Contractor
Inspections
Inspection Notes Performed By Date
Cancelled: Re-Roof - In Progress Melissa Garber 1/17/2025
Passed: Re-Roof - In Progress Troy Crews 1/21/2025
Passed: Re-Roof - Final Troy Crews 2/24/2025