Columbia County is committed to ensuring accessibility to this website regardless of disability. If anyone encounters a feature on this website that is inaccessible due to a disability, please contact the County Manger’s Office and the Columbia County Board of County Commissioners at (386) 758-1005. You may also email that office at patrick_weaver@columbiacountyfla.com and provide a brief description of the inaccessible feature. The County will either correct the inaccessible feature or, if correction is not possible due to technical limitations, provide the desired information through alternative means.

Skip to content

Columbia County, FL | Permit Details

New Residential Construction Permit

Address 3564 NW BROWN RD
LAKE CITY, FL 32055
Parcel #: 02181-007
Acres: 9.95
Owner: Smithey Bryan B, Smithey Robin L
Subdivision:
Zoning: A-3
Flood Zone: X
District: 3
Application #: 67936
Permit #: 000051574
Related Permit:
Submitted: Monday, November 4, 2024
Issued: Wednesday, November 20, 2024
Expires: Monday, September 1, 2025
Completed: Monday, September 1, 2025
Status: Completed
Septic Release? Yes
Notes:
MFE = 1' ABOVE ROAD
Job Details
Elevation regulation Minimum Requirement
Finished floor requirement One foot above the road
Fema map number 12023C0280D
This is the construction of a Single Family Dwelling
Setbacks Front 30'
Setback Side 1 25'
Setback Side 2 25'
Setbacks Rear 25'
Stories 1
Heated Area (Sqft) 1910
Total Area (Sqft) 3868
Building Height 18
Building Code Construction Type V
Building Code Element B
Building Code Occupancy Types Residential
Occupancy Use Title single family dwelling
Building Code Edition 2023 Florida Building Code 8th Edition and 2020 National Electrical Code
Septic# (00-0000) or (X00-000) 24-0754
Sealed roof decking options. (Must select one option per FBC 2023 8th Edition) two layers of felt underlayment comply ASTM 0226 Type II or ASTM D4869 Type Ill or IV, or two layers of a synthetic underlayment meeting the performance requirements specified, lapped and fastened as specified.
Service Amps 200
Review Notes
11/4/2024 Point Review - Status Cleared
11/4/2024 Point Review - Processing
11/5/2024 Point Review - Reviewed
11/13/2024 Zoning Review - Reviewed
11/18/2024 Plan Review - Plumbing Approved
11/18/2024 Plan Review - Mechanical Approved
11/18/2024 Plan Review - Electrical Approved
11/18/2024 Plan Review - Building Approved
11/18/2024 Plan Review - Reviewed
11/18/2024 Final Review - Documents Required
11/20/2024 Final Review - Payment Needed
11/20/2024 Permit Issued
Contractors
Name/ Business License Title Role
Matthew A Erkinger,sr.
Erkinger Construction Group
Liability Insurance Expired.
CRC1330825 Residential Contractor Contractor
Donald R Davis
High Springs Electric Inc
CAC1815367 Class B A/c Subcontractor
Richard C Register
Register's Heating & Air Conditioning,inc.
CAC041267 Class B Subcontractor
Cody Barrs
Barrs Plumbing Inc
CFC1427145 Plumbing Contractor Subcontractor
Wallace W Powell
Powell & Sons Roofing,inc.
CCC057307 Roofing Contractor Subcontractor
Inspections
Inspection Notes Performed By Date
Passed: Building - Footer Check For Washouts After The Rain Matt Forsyth 12/11/2024
Passed: Engineering - Setbacks Matt Forsyth 12/11/2024
Passed: Electrical - 1st Underground Rough–In Under Slab Chase Gary Pitzer 12/26/2024
Passed: Plumbing/Gas - 1st Underground Rough–In Dwv Under Slab, No Water. Please Post Readable Address To Property At Brown Rd Gary Pitzer 12/26/2024
Passed: Building - Slab Plastic Taped, Steel Around Perimeter ,ground Wire Off Footer Steel Gary Pitzer 1/2/2025
Passed: Building - Roof Decking Front Porch Decking Will Be Looked At Framing Inspection Matt Forsyth 2/11/2025
Passed: Building - Wall Sheathing Matt Forsyth 2/11/2025
Septic Release Inspection Health Dept 2/20/2025
Failed: Re-Roof - Final Roof Is Not Complete Please Send Pictures Of Completion In Before Rescheduling Matt Forsyth 3/13/2025
Passed: Electrical - 2nd Rough-In Matt Forsyth 3/28/2025
Passed: Mechanical - Rough In Attic Design For Air Handler Matt Forsyth 3/28/2025
Passed: Plumbing/Gas - 2nd Rough-In Fireplace Gas Matt Forsyth 3/28/2025
Passed: Plumbing/Gas - Tub Set/Shower Pan Matt Forsyth 3/28/2025
Rescheduled 3/31/2025:Building - Framing Matt Forsyth 3/28/2025
Passed: Building - Framing Collar Ties Will Need Engineering Matt Forsyth 3/31/2025
Passed: Building - Insulation Matt Forsyth 4/14/2025
Passed: Electrical - Permanent Power Matt Forsyth 8/25/2025
Release to power company Ok To Release Power-- 8.25.25 Mg Matt Forsyth 8/25/2025
Submitted Power Release through FPL Portal Garber, Melissa 8/25/2025
Passed: Building - Final Blower Door Test Reviewed Fresh Air Confirmed Matt Forsyth 8/29/2025