Columbia County is committed to ensuring accessibility to this website regardless of disability. If anyone encounters a feature on this website that is inaccessible due to a disability, please contact the County Manger’s Office and the Columbia County Board of County Commissioners at (386) 758-1005. You may also email that office at patrick_weaver@columbiacountyfla.com and provide a brief description of the inaccessible feature. The County will either correct the inaccessible feature or, if correction is not possible due to technical limitations, provide the desired information through alternative means.

Skip to content

Columbia County, FL | Permit Details

Roof Replacement or Repair Permit
Address 531 SW CHOCTAW AVE
FORT WHITE, FL 32038
Parcel #: 03816-312
Acres: 10.02
Owner: Karamolengos Babis
Subdivision: Tustenuggee Trails Unr
Zoning: A-3
Flood Zone: X
District: 4
Application #: 68218
Permit #: 000051557
Related Permit:
Submitted: Tuesday, November 19, 2024
Issued: Tuesday, November 19, 2024
Expires: Wednesday, December 18, 2024
Completed: Wednesday, December 18, 2024
Status: Completed
Septic Release? na
Notes:

Job Details
Type Roofing Job Partial Roof Repairs
Further Job Details (Explain if decking is being replaced and or Repairs are being done.) Remove damaged metal panels and replace with new 26G galvalume metal panels. Re-screw entire house and porch.
Type of structure Mobile Home
Commercial or Residential Residential
Roof Area (for this job) Sq Ft 2252
No. of Stories 1
Ventilation: Ridge Vent
Flashing: Use Existing
Drip Edge: Use Existing
Valley Treatment: New Metal
Roof Pitch 2:12 to 4:12
Any cable and/or race-way wiring located on or within the roof assembly? No
Is the existing roof being removed? Yes
Explain if not removing the existing roofing material? 5 sq of existing roof is being removed and replaced.
Type of New Roofing Product Metal
Florida Product Approval Number FL30343.04-R3
Product Manufacturer Premier Metal Roof MFG
Product Description Exposed fastener, rib style panel. Panel coverage is nominally 36” with nominal rib height of 3/4”
Sealed roof decking options: (Must select an option.) two layers of felt underlayment comply ASTM 0226 Type II or ASTM D4869 Type Ill or IV, or two layers of a synthetic underlayment meeting the performance requirements specified, lapped and fastened as specified.
Building Code Edition 2023 Florida Building Code 8th Edition and 2020 National Electrical Code
Fema map number 12023C0485C
Review Notes
11/19/2024 Application pending.
11/19/2024 Application submitted by applicant.
11/19/2024 Final Review - Payment Needed
11/19/2024 Permit Issued Permit # created and approved from payment.
Contractors
Name/ Business License Title Role
Derek King
True Force Roofing
CCC1335679 Cert. Roofing Contractor
Inspections
Inspection Notes Performed By Date
Passed: Re-Roof - In Progress Gary Pitzer 12/13/2024
Passed: Re-Roof - Final Roof Repair From Storm Damage Gary Pitzer 12/18/2024