Type Roofing Job |
Replacement - Tear off Existing and Replace |
Further Job Details (Explain if decking is being replaced and or Repairs are being done.) |
this permit is for garage only. Roof is already completed. The main home and garage roof were installed at the same time. We only applied for one permit, when we should have applied for two. The main home permit # 51109 |
Type of structure |
Storage or Garage Building |
Commercial or Residential |
Residential |
Roof Area (for this job) Sq Ft |
14 |
No. of Stories |
1 |
Ventilation: |
Ridge Vent |
Flashing: |
Use Existing |
Drip Edge: |
Replace All |
Valley Treatment: |
New Metal |
Roof Pitch |
4:12 or Greater |
Any cable and/or race-way wiring located on or within the roof assembly? |
No |
Is the existing roof being removed? |
Yes |
Type of New Roofing Product |
Asphalt Shingles |
Florida Product Approval Number |
FL18355_R11 |
Product Manufacturer |
TAMKO Asphalt Shingles |
Product Description |
ASTM D3462 asphalt shingles and hip and ridge shingles |
Sealed roof decking options: (Must select an option.) |
a minimum 4-inch wide strip of selfadhering polymer-modified bitumen complying with ASTM D1970 or a minimum 3 ¾ - inch wide strip of selfadhering flexible flashing tape complying with AAMA 711, applied over all joints in the roof decking. A felt underlayment complying with ASTM D226 Type II, ASTM D4869 Type Ill or IV, or ASTM D6757, or a synthetic underlayment meeting the performance requirements specified, is required to be applied over the strips/tape over the entire roof. |
Building Code Edition |
2023 Florida Building Code 8th Edition and 2020 National Electrical Code |
Fema map number |
12023C0292D |