Columbia County is committed to ensuring accessibility to this website regardless of disability. If anyone encounters a feature on this website that is inaccessible due to a disability, please contact the County Manger’s Office and the Columbia County Board of County Commissioners at (386) 758-1005. You may also email that office at patrick_weaver@columbiacountyfla.com and provide a brief description of the inaccessible feature. The County will either correct the inaccessible feature or, if correction is not possible due to technical limitations, provide the desired information through alternative means.

Skip to content

Columbia County, FL | Permit Details

Roof Replacement or Repair Permit
Address 262 SW WINTHROP PL
FORT WHITE, FL 32038
Parcel #: 03832-235
Acres: 5.20
Owner: O'byrne Ana Maria, O'byrne Loundres
Subdivision: Spring Run Unr Phase 1
Zoning: A-3
Flood Zone: X
District: 2
Application #: 68036
Permit #: 000051467
Related Permit:
Submitted: Friday, November 8, 2024
Issued: Tuesday, November 12, 2024
Expires: Tuesday, December 17, 2024
Completed: Tuesday, December 17, 2024
Status: Completed
Septic Release? na
Notes:

Job Details
Type Roofing Job Replacement - Tear off Existing and Replace
Further Job Details (Explain if decking is being replaced and or Repairs are being done.) Remove existing shingles and replace with new shingles on single family residence.
Type of structure House
Commercial or Residential Residential
Roof Area (for this job) Sq Ft 3196
No. of Stories 1
Ventilation: Ridge Vent
Flashing: Use Existing
Drip Edge: Replace All
Valley Treatment: Use Existing
Roof Pitch 4:12 or Greater
Any cable and/or race-way wiring located on or within the roof assembly? No
Is the existing roof being removed? Yes
Type of New Roofing Product Asphalt Shingles
Florida Product Approval Number 10124.1
Product Manufacturer GAF Asphalt Roof Shingles (HVHZ)
Product Description Fiberglass reinforced, laminated asphalt shingles for use in FBC HVHZ jurisdictions.
Sealed roof decking options: (Must select an option.) two layers of felt underlayment comply ASTM 0226 Type II or ASTM D4869 Type Ill or IV, or two layers of a synthetic underlayment meeting the performance requirements specified, lapped and fastened as specified.
Building Code Edition 2023 Florida Building Code 8th Edition and 2020 National Electrical Code
Fema map number 12023C0480C
Review Notes
11/8/2024 Application pending.
11/8/2024 Application submitted by applicant.
11/8/2024 Final Review - Payment Needed
11/12/2024 Permit Issued Permit # created and approved from payment.
Contractors
Name/ Business License Title Role
Derek King
True Force Roofing
CCC1335679 Cert. Roofing Contractor
Inspections
Inspection Notes Performed By Date
Passed: Re-Roof - In Progress Matt Forsyth 12/11/2024
Passed: Re-Roof - Final Matt Forsyth 12/17/2024