Columbia County is committed to ensuring accessibility to this website regardless of disability. If anyone encounters a feature on this website that is inaccessible due to a disability, please contact the County Manger’s Office and the Columbia County Board of County Commissioners at (386) 758-1005. You may also email that office at patrick_weaver@columbiacountyfla.com and provide a brief description of the inaccessible feature. The County will either correct the inaccessible feature or, if correction is not possible due to technical limitations, provide the desired information through alternative means.

Skip to content

Columbia County, FL | Permit Details

Roof Replacement or Repair Permit

Address 137 SE FONTANA GLN
LAKE CITY, FL 32025
Parcel #: 08302-014
Acres: 1.61
Owner: Fraze Richard R Jr, Fraze Thresa B
Subdivision: Deerwood Forest Unit 1
Zoning: RSF-2
Flood Zone: X
District: 5
Application #: 67806
Permit #: 000051361
Related Permit:
Submitted: Monday, October 28, 2024
Issued: Friday, November 1, 2024
Expires: Thursday, December 26, 2024
Completed: Thursday, December 26, 2024
Status: Completed
Septic Release? na
Notes:

Job Details
Finished floor requirement
Fema map number 12023C0313D
Type Roofing Job Replacement - Tear off Existing and Replace
Type of structure House
Commercial or Residential Residential
Roof Area (for this job) Sq Ft 26
No. of Stories 1
Roof Pitch 4:12 or Greater
Is the existing roof being removed? Yes
Type of New Roofing Product Asphalt Shingles
Florida Product Approval Number FL10674-r19
Product Manufacturer Owens Corning Asphalt Roof Shingles
Product Description Asphalt Shingles
Building Code Edition 2023 Florida Building Code 8th Edition and 2020 National Electrical Code
Sealed roof decking options: (Must select an option.) a minimum 4-inch wide strip of selfadhering polymer-modified bitumen complying with ASTM D1970 or a minimum 3 ¾ - inch wide strip of selfadhering flexible flashing tape complying with AAMA 711, applied over all joints in the roof decking. A felt underlayment complying with ASTM D226 Type II, ASTM D4869 Type Ill or IV, or ASTM D6757, or a synthetic underlayment meeting the performance requirements specified, is required to be applied over the strips/tape over the entire roof.
Ventilation: Ridge Vent
Flashing: Use Existing
Drip Edge: Replace All
Valley Treatment: New Metal
Any cable and/or race-way wiring located on or within the roof assembly? No
Review Notes
Contractors
Name/ Business License Title Role
Tyler M Turner
Tmt Roofing Llc
CCC1330410 Cert Roofing Contractor
Inspections
Inspection Notes Performed By Date
Passed: Re-Roof - In Progress Anthony Aslan 12/10/2024
Failed: Re-Roof - Final 1. There Is A Large Portion Of Shingles Sticking Up, 2. What Type Of Material Was Used On The Low Slope Area Of Roof [need Photos] Gary Pitzer 12/12/2024
Failed: Re-Roof - Final This Roof Still Has Shingles Sticking Up. This Will Have To Get Better Before I Will Pass Roof. Owner Is Not Pleased With Job As It Stands. Gary Pitzer 12/16/2024
Passed: Re-Roof - Final Per Manufactures Tech. Bulletin On Shingles Gary Pitzer 12/26/2024
Documents
File Name Date File Size