Columbia County is committed to ensuring accessibility to this website regardless of disability. If anyone encounters a feature on this website that is inaccessible due to a disability, please contact the County Manger’s Office and the Columbia County Board of County Commissioners at (386) 758-1005. You may also email that office at patrick_weaver@columbiacountyfla.com and provide a brief description of the inaccessible feature. The County will either correct the inaccessible feature or, if correction is not possible due to technical limitations, provide the desired information through alternative means.

Skip to content

Columbia County, FL | Permit Details

New Commercial Construction Permit

Address 3847 S. U.S. HWY 441
LAKE CITY, FLORIDA 32025
Parcel #: 08410-101
Acres: 3.67
Owner: Forty Seven Development Llc,
Subdivision: Capital Business Park
Zoning: ILW
Flood Zone: X
District: 4
Application #: 67424
Permit #: 000051354
Related Permit:
Submitted: Tuesday, October 8, 2024
Issued: Friday, November 1, 2024
Expires: Tuesday, June 3, 2025
Completed: Tuesday, June 3, 2025
Status: Completed
Septic Release? Yes
Notes:
APPROVED SITE PLAN SDP-240901 FINISHED FLOOR 99 FEET PER SITE PLAN ELEVATION CONFIRMATION BY SURVEYOR REQUIRED AT SLAB POUR
LAKE CITY UTLITY CUSTOMER SERVICE NOTES Locates must be obtained to ensure that the existing utility infrastructure is not damaged or obstructed.
Job Details
Finished floor requirement
Fema map number 12023C0380C
Type Roofing Job Replacement - Tear off Existing and Replace
Further Job Details (Explain if decking is being replaced and or Repairs are being done.) Replace wood as needed
Type of structure House
Commercial or Residential Residential
Roof Area (for this job) Sq Ft 34
No. of Stories 1
Roof Pitch 4:12 or Greater
Is the existing roof being removed? Yes
Type of New Roofing Product Asphalt Shingles
Florida Product Approval Number FL18355-R8
Product Manufacturer TAMKO
Product Description HERITAGE
Building Code Edition 2020 Florida Building Code 7th Edition and Florida Statute 553.844
Sealed roof decking options: (Must select an option.) two layers of felt underlayment comply ASTM 0226 Type II or ASTM D4869 Type Ill or IV, or two layers of a synthetic underlayment meeting the performance requirements specified, lapped and fastened as specified.
Ventilation: Ridge Vent
Flashing: Use Existing
Drip Edge: Replace All
Valley Treatment: New Metal
Any cable and/or race-way wiring located on or within the roof assembly? No
Review Notes
10/8/2024 Application pending.
10/8/2024 Application submitted by applicant.
10/8/2024 City of Lake City Utilities Notified.
10/9/2024 Point Review - Processing
10/9/2024 Zoning Review - Reviewed
10/9/2024 Plan Review - Documents Required
10/21/2024 Plan Review - Documents Required
10/23/2024 Plan Review - Documents Required
10/25/2024 Plan Review - Documents Required
10/30/2024 Plan Review - Documents Required
10/30/2024 Plan Review - Documents Required
10/31/2024 Plan Review - Plumbing Approved
10/31/2024 Plan Review - Mechanical Approved
10/31/2024 Plan Review - Electrical Approved
10/31/2024 Plan Review - Building Approved
10/31/2024 Plan Review - Reviewed
10/31/2024 Final Review - Processing
10/31/2024 Final Review - Payment Needed
11/1/2024 Permit Issued
11/21/2024 Point Review - Processing
Contractors
Name/ Business License Title Role
Kevin L Bedenbaugh Jr
Plumb Level Construction Co Llc
CGC1516042 General Contractor Contractor
Cody Barrs
Barrs Plumbing Inc
CFC1427145 Plumbing Contractor Subcontractor
Kevin L Bedenbaugh Jr
Plumb Level Construction Co Llc
CCC1329482 Roofing Contractor Subcontractor
Ryan Felknor
Felknor Electric, Inc.
EC13003153 Electrical Contractor Subcontractor
Clinton G Wilson
Wilson Heat & Air Inc
CAC057886 Class B A/c Subcontractor
Inspections
Inspection Notes Performed By Date
Passed: Fire - Plan Review All Requirements Appear To Be Met At This Time. Cpt. Shane Overstreet 10/9/2024
Passed: Plumbing/Gas - 1st Underground Rough–In Troy Crews 11/20/2024
Passed: Building - Monolithic Slab Troy Crews 11/22/2024
Passed: Engineering - Setbacks Troy Crews 11/22/2024
Passed: Building - Framing Troy Crews 2/27/2025
Passed: Electrical - 2nd Rough-In Troy Crews 2/27/2025
Passed: Mechanical - Rough In Troy Crews 2/27/2025
Passed: Plumbing/Gas - 2nd Rough-In Troy Crews 2/27/2025
Passed: Building - Insulation Troy Crews 3/6/2025
Passed: Electrical - Permanent Power Need Septic Final Troy Crews 4/11/2025
Release to power company Melissa Garber 5/15/2025
Septic Release Inspection Co On Hold Until Water Testing Complete Per Env Health-- 5.15.25 Mg Health Dept 5/15/2025
Passed: Building - Final All Requirements Met-- Ok To Issue Co-- 6.3.25 Mg Troy Crews 5/30/2025
Passed: Fire - Fire Final Cpt. Shane Overstreet 6/2/2025
Passed: Certificate-Release Certificate Troy Crews 6/3/2025
Documents
File Name Date File Size