Columbia County is committed to ensuring accessibility to this website regardless of disability. If anyone encounters a feature on this website that is inaccessible due to a disability, please contact the County Manger’s Office and the Columbia County Board of County Commissioners at (386) 758-1005. You may also email that office at patrick_weaver@columbiacountyfla.com and provide a brief description of the inaccessible feature. The County will either correct the inaccessible feature or, if correction is not possible due to technical limitations, provide the desired information through alternative means.

Skip to content

Columbia County, FL | Permit Details

Roof Replacement or Repair Permit
Address 193 NE RIFLE CT
LAKE CITY, FL 32055
Parcel #: 07313-000
Acres: 1.76
Owner: Udell Stacy L
Subdivision:
Zoning: I
Flood Zone: X
District: 1
Application #: 67830
Permit #: 000051336
Related Permit:
Submitted: Wednesday, October 30, 2024
Issued: Thursday, October 31, 2024
Expires: Wednesday, November 6, 2024
Completed: Wednesday, November 6, 2024
Status: Completed
Septic Release? na
Notes:

Job Details
Type Roofing Job Replacement - Tear off Existing and Replace
Further Job Details (Explain if decking is being replaced and or Repairs are being done.) Re-roof using Owens Corning asphalt shingles and peel and stick underlayment
Type of structure House
Commercial or Residential Residential
Roof Area (for this job) Sq Ft 30
No. of Stories 1
Ventilation: Ridge Vent
Flashing: Replace with L-Flashing
Drip Edge: Replace All
Valley Treatment: New Mineral Surface
Roof Pitch 4:12 or Greater
Any cable and/or race-way wiring located on or within the roof assembly? No
Is the existing roof being removed? Yes
Type of New Roofing Product Asphalt Shingles
Florida Product Approval Number FL10674_R19, FL32344_R2
Product Manufacturer Owens Corning
Product Description Shingles and P/S Underlayment
Sealed roof decking options: (Must select an option.) a minimum 4-inch wide strip of selfadhering polymer-modified bitumen complying with ASTM D1970 or a minimum 3 ¾ - inch wide strip of selfadhering flexible flashing tape complying with AAMA 711, applied over all joints in the roof decking. A felt underlayment complying with ASTM D226 Type II, ASTM D4869 Type Ill or IV, or ASTM D6757, or a synthetic underlayment meeting the performance requirements specified, is required to be applied over the strips/tape over the entire roof.;two layers of felt underlayment comply ASTM 0226 Type II or ASTM D4869 Type Ill or IV, or two layers of a synthetic underlayment meeting the performance requirements specified, lapped and fastened as specified.
Sealed roof decking explanation for other option. p/s underlayment throughout roof
Building Code Edition 2023 Florida Building Code 8th Edition and 2020 National Electrical Code
Fema map number 12023C0305D
Review Notes
10/29/2024 Application pending.
10/30/2024 Application submitted by applicant.
10/30/2024 City of Lake City Utilities Notified. City of Lake City Notified of Application within Utility Service Areas LC_GAS,.
10/30/2024 Final Review - Corrections Needed NEED * OWNER'S PHONE NUMBER * SCOTT D HOFF NEEDS TO REGISTER WITH US AT WWW.COLUMBIACOUNTYFLA.COM
10/30/2024 Final Review - Payment Needed
10/30/2024 Final Review - Payment Needed
10/31/2024 Permit Issued Permit # created and approved from payment.
Contractors
Name/ Business License Title Role
Scott D Hoff
Hp storm restoration, llc
CCC1331253 Cert. Roofing Contractor
Inspections
Inspection Notes Performed By Date
Passed: Re-Roof - In Progress Roof Complete Anthony Aslan 11/4/2024
Passed: Re-Roof - Final Anthony Aslan 11/6/2024