Permit Details

Permit Search

Permit

New Residential Construction

1879 SW SISTERS WELCOME RD
LAKE CITY, FL 32025

Permit #
000051310
Application #
66103
Status Completed
  1. Submitted Aug 1, 2024
  2. Issued Oct 30, 2024
  3. Expires Oct 20, 2025
  4. Completed Apr 23, 2025

Property

Parcel #
02935-010
Owner
Decker Daniel B, Decker Jeanne H
Acres
0.69
Subdivision
Brothers Welcome Airpark
Zoning
RMF-1
Flood zone
0.2 PCT ANNUAL CHANCE FLOOD HAZARD
District
5

Permit

Status
Completed
Septic release
Not yet released
Related permit
—

Job Details

Elevation regulation
Special Flood Hazard Area
Finished floor requirement
128' One foot above FEMA Map Elevation
Requirement needed
By Permanent Power Inspection
Document needed is
an Elevation Certificate for Finished Construction
Document receieved
Yes
Fema map number
12023C0291D
Water source
Sante Fe
In floodway
N
This is the construction of a
Single Family Dwelling
Setbacks Front
20'
Setback Side 1
10'
Setback Side 2
10'
Setbacks Rear
15'
Stories
1
Heated Area (Sqft)
920
Total Area (Sqft)
2904
Building Code Construction Type
V
Building Code Element
B
Building Code Occupancy Types
Residential
Occupancy Use Title
single family dwelling
Building Code Edition
2023 Florida Building Code 8th Edition and 2020 National Electrical Code
Septic# (00-0000) or (X00-000)
24-0534
Sealed roof decking options. (Must select one option per FBC 2023 8th Edition)
a minimum 4-inch wide strip of selfadhering polymer-modified bitumen complying with ASTM D1970 or a minimum 3 ¾ - inch wide strip of selfadhering flexible flashing tape complying with AAMA 711, applied over all joints in the roof decking. A felt underlayment complying with ASTM D226 Type II, ASTM D4869 Type Ill or IV, or ASTM D6757, or a synthetic underlayment meeting the performance requirements specified, is required to be applied over the strips/tape over the entire roof.
Service Amps
200

Status & Review History

  1. Application pending.
  2. Application submitted by applicant.
  3. City of Lake City Utilities Notified.
  4. Point Review - Reviewed
  5. Zoning Review - Documents Required
  6. Zoning Review - Documents Required
  7. Zoning Review - Reviewed
  8. Plan Review - Plumbing Approved
  9. Plan Review - Mechanical Approved
  10. Plan Review - Electrical Approved
  11. Plan Review - Building Approved
  12. Plan Review - Reviewed
  13. Final Review - Processing
  14. Final Review - Payment Needed
  15. Permit Issued
  16. Point Review - Reviewed
  17. Zoning Review - Reviewed

Contractors

  • Bryan Zecher

    Bryan Zecher Homes Inc

    License
    CBC1257343
    Title
    Building Contractor
    Role
    Contractor
  • Donald Hollingsworth Ii

    Holly Electric Inc

    License
    EC13012104
    Title
    Cert. Electrical
    Role
    Subcontractor
  • Anthony R Franks

    Lane Heating & Air Llc

    License
    CAC1818631
    Title
    Cert. A/c Class “b”
    Role
    Subcontractor

    County License & State License Expired.

  • Cody Barrs

    Barrs Plumbing Inc

    License
    CFC1427145
    Title
    Plumbing Contractor
    Role
    Subcontractor
  • Robert Ogles

    Ogles Roofing & Construction Llc

    License
    CCC1328699
    Title
    Cert Roofing
    Role
    Subcontractor

    County License & State License Expired.

Inspections

  1. Oct 31, 2024

    Passed: Building - Footer

    Inspected by Troy Crews

  2. Oct 31, 2024

    Passed: Engineering - Setbacks

    Inspected by Troy Crews

  3. Nov 12, 2024

    Passed: Plumbing/Gas - 1st Underground Rough–In

    Inspected by Gary Pitzer

  4. Nov 12, 2024

    Passed: Electrical - 1st Underground Rough–In

    Inspected by Gary Pitzer

  5. Nov 12, 2024

    Passed: Building - Footer

    Inspected by Gary Pitzer

  6. Nov 12, 2024

    Passed: Engineering - Setbacks

    Inspected by Gary Pitzer

  7. Nov 15, 2024

    Passed: Building - Slab

    Wire Steel And Plastic Taped

    Inspected by Gary Pitzer

  8. Dec 4, 2024

    Passed: Building - Roof Decking

    Inspected by Gary Pitzer

  9. Dec 4, 2024

    Passed: Building - Wall Sheathing

    Inspected by Gary Pitzer

  10. Dec 19, 2024

    Passed: Building - Wall Sheathing

    Inspected by Gary Pitzer

  11. Dec 19, 2024

    Passed: Building - Strapping

    Inspected by Gary Pitzer

  12. Dec 19, 2024

    Passed: Building - Roof Decking

    Inspected by Gary Pitzer

  13. Dec 19, 2024

    Passed: Building - Framing

    Inspected by Gary Pitzer

  14. Dec 27, 2024

    Passed: Electrical - 2nd Rough-In

    Inspected by Gary Pitzer

  15. Dec 27, 2024

    Passed: Mechanical - Rough In

    Inspected by Gary Pitzer

  16. Dec 27, 2024

    Passed: Plumbing/Gas - 2nd Rough-In

    Inspected by Gary Pitzer

  17. Jan 8, 2025

    Passed: Building - Insulation

    Foam Roof, Bat Waalls

    Inspected by Gary Pitzer

  18. Jan 15, 2025

    Passed: Building - Fire Rated Wall

    2 Layers Staggered

    Inspected by Gary Pitzer

  19. Feb 26, 2025

    Passed: Electrical - Permanent Power

    Inspected by Gary Pitzer

  20. Feb 26, 2025

    Release to power company

    Inspected by Gary Pitzer

  21. Apr 23, 2025

    Passed: Building - Final

    Inspected by Gary Pitzer