Permit Details

Permit Search

Permit

Roof Replacement or Repair

285 SW CYPRESSWOOD GLN
LAKE CITY, FL 32025

Permit #
000051139
Application #
67622
Status Completed
  1. Submitted Oct 17, 2024
  2. Issued Oct 17, 2024
  3. Expires Jun 3, 2025
  4. Completed Dec 5, 2024

Property

Parcel #
09415-118
Owner
Congdon Christopher J, Congdon Elizabeth R
Acres
5.01
Subdivision
Magnolia Place
Zoning
A-3
Flood zone
X
District
4

Permit

Status
Completed
Septic release
N/A
Related permit
—

Job Details

Finished floor requirement
Fema map number
12023C0415C
Type Roofing Job
Replacement - Tear off Existing and Replace
Further Job Details (Explain if decking is being replaced and or Repairs are being done.)
Reroof Shingle to Shingle 42sq 7/12
Type of structure
House
Commercial or Residential
Residential
Roof Area (for this job) Sq Ft
4200
No. of Stories
1
Roof Pitch
4:12 or Greater
Is the existing roof being removed?
Yes
Type of New Roofing Product
Asphalt Shingles
Florida Product Approval Number
FL30310.1
Product Manufacturer
IKO
Product Description
Dynasty
Building Code Edition
2023 Florida Building Code 8th Edition and 2020 National Electrical Code
Sealed roof decking options: (Must select an option.)
two layers of felt underlayment comply ASTM 0226 Type II or ASTM D4869 Type Ill or IV, or two layers of a synthetic underlayment meeting the performance requirements specified, lapped and fastened as specified.
Ventilation:
Ridge Vent
Flashing:
Replace All
Drip Edge:
Replace All
Valley Treatment:
New Mineral Surface
Any cable and/or race-way wiring located on or within the roof assembly?
No

Status & Review History

  1. Application pending.
  2. Application submitted by applicant.
  3. Final Review - Payment Needed
  4. Permit Issued

Contractors

  • Chadley Smith

    Erie Construction Mid West Llc

    License
    CCC1334300
    Title
    Cert. Roofing
    Role
    Contractor

    County License & State License & Liability Insurance & Workers Comp Expired.

Inspections

  1. Oct 24, 2024

    Passed: Re-Roof - In Progress

    Inspected by Gary Pitzer

  2. Dec 5, 2024

    Passed: Re-Roof - Final

    Inspected by Gary Pitzer