| Application #: | 66679 |
| Permit #: |
000051040 |
| Related Permit: |
|
| Submitted: | Monday, August 19, 2024 |
| Issued: | Friday, October 11, 2024 |
| Expires: | Thursday, October 31, 2024 |
| Completed: | Thursday, October 31, 2024 |
| Status: |
Completed |
| Septic Release? |
Yes |
Notes
ZONING: ATTACHED CARPORT
| Elevation regulation |
None |
| Finished floor requirement |
Non-Habitable Structure |
| Fema map number |
12023C0260C |
| Description of addition: |
Carport |
| Select driveway access to property: |
Existing Drive |
| Fire sprinklers? |
No |
| Setbacks Front |
30' |
| Setback Side 1 |
25' |
| Setback Side 2 |
25' |
| Setback Rear |
25' |
| Stories |
1 |
| Heated Area (Sqft) |
0 |
| Total Area (Sqft) |
437 |
| Total Estimated Cost |
25000 |
| Building Height |
15 |
| Building Code Construction Type |
V |
| Building Code Element |
B |
| Building Code Occupancy Types |
Residential |
| Occupancy Use Title |
carport |
| Dev Permit # |
F023- |
| Building Code Edition |
2023 Florida Building Code 8th Edition and 2020 National Electrical Code |
| Septic# |
24-0588 |
| Is this an addition for commercial or residential use? |
Residential |
| Sealed roof decking options. (Must select one.) |
a minimum 4-inch wide strip of selfadhering polymer-modified bitumen complying with ASTM D1970 or a minimum 3 ¾ - inch wide strip of selfadhering flexible flashing tape complying with AAMA 711, applied over all joints in the roof decking. A felt underlayment complying with ASTM D226 Type II, ASTM D4869 Type Ill or IV, or ASTM D6757, or a synthetic underlayment meeting the performance requirements specified, is required to be applied over the strips/tape over the entire roof. |
| Service Amps |
200 |
| 8/16/2024 |
Application pending. |
| 8/19/2024 |
Application submitted by applicant. |
| 8/26/2024 |
Point Review - Printed-Online Application |
| 8/28/2024 |
Zoning Review - Reviewed |
| 9/3/2024 |
Plan Review - Corrections Needed |
| 9/5/2024 |
Plan Review - Reviewed |
| 9/10/2024 |
Final Review - Corrections Needed |
| 9/12/2024 |
Final Review - Corrections Needed |
| 10/8/2024 |
Final Review - Reviewed |
| 10/8/2024 |
Final Review - Payment Needed |
| 10/10/2024 |
Final Review - Payment Needed |
| 10/11/2024 |
Permit Issued |
| Name / Business |
License |
Title |
Role |
Cody Barrs Barrs Plumbing Inc
|
CFC1427145 |
Plumbing Contractor |
Subcontractor |
Robert Ogles Ogles Roofing & Construction Llc
County License & State License Expired. |
CCC1328699 |
Cert Roofing |
Subcontractor |
Donald R Hollingsworth Holly Electric Inc
|
EC13005429 |
Electrical |
Subcontractor |
Anthony R Franks Lane Heating & Air Llc
County License & State License Expired. |
CAC1818631 |
Cert. A/c Class “b” |
Subcontractor |
Bryan Zecher Bryan Zecher Construction Inc
|
CBC054575 |
Cert.building Contractor |
Contractor |
| Inspection |
Notes |
Performed By |
Date |
| Septic Release Inspection |
|
Health Dept |
9/4/2024 |
| Failed: Building - Ext Strapping/Wall Sheathing |
Not Ready Please Reschedule |
Matt Forsyth |
10/15/2024 |
| Failed: Building - Framing |
Project Not Ready For Inspection Please Reschedule |
Matt Forsyth |
10/15/2024 |
| Failed: Building - Ext Strapping/Wall Sheathing |
|
Matt Forsyth |
10/16/2024 |
| Failed: Building - Framing |
|
Matt Forsyth |
10/16/2024 |
| Certificate-Release Certificate |
|
Troy Crews |
10/31/2024 |
| Passed: Building - Final |
Cannot Closed Permit Or Release Certificate Of Occupancy Due To Missing Required Documents. |
Troy Crews |
10/31/2024 |