Permit Details

Permit Search

Permit

New Residential Construction

182 SW CADENCE GLN
LAKE CITY, FL 32024

Permit #
000050886
Application #
66788
Status Completed
  1. Submitted Aug 26, 2024
  2. Issued Oct 21, 2024
  3. Expires Jul 16, 2025
  4. Completed Jan 17, 2025

Property

Parcel #
03001-102
Owner
Maronda Homes, Llc
Acres
0.99
Subdivision
Forest Cove
Zoning
RSF-2
Flood zone
X
District
3

Permit

Status
Completed
Septic release
Released
Related permit
—

Job Details

Elevation regulation
Minimum Requirement
Finished floor requirement
94.9'
Requirement needed
By Nailing Inspection
Document needed is
a Surveyor letter giving the Finished Floor Elevation
Document receieved
Yes
Fema map number
12023C0289D
This is the construction of a
Single Family Dwelling
Setbacks Front
25'
Setback Side 1
10'
Setback Side 2
10'
Setbacks Rear
15'
Stories
1
Heated Area (Sqft)
1876
Total Area (Sqft)
2379
Building Height
17.5
Building Code Construction Type
V
Building Code Element
B
Building Code Occupancy Types
Residential
Occupancy Use Title
single family dwelling
Building Code Edition
2023 Florida Building Code 8th Edition and 2020 National Electrical Code
Septic# (00-0000) or (X00-000)
24-0642
Sealed roof decking options. (Must select one option per FBC 2023 8th Edition)
a minimum 4-inch wide strip of selfadhering polymer-modified bitumen complying with ASTM D1970 or a minimum 3 ¾ - inch wide strip of selfadhering flexible flashing tape complying with AAMA 711, applied over all joints in the roof decking. A felt underlayment complying with ASTM D226 Type II, ASTM D4869 Type Ill or IV, or ASTM D6757, or a synthetic underlayment meeting the performance requirements specified, is required to be applied over the strips/tape over the entire roof.
Service Amps
200

Status & Review History

  1. Application pending.
  2. Application submitted by applicant.
  3. Point Review - Printed-Online Application
  4. Zoning Review - Reviewed
  5. Plan Review - Corrections Needed
  6. Plan Review - On Hold-Incomplete
  7. Plan Review - On Hold-Incomplete
  8. Plan Review - Building Approved
  9. Plan Review - Electrical Approved
  10. Plan Review - Mechanical Approved
  11. Plan Review - Plumbing Approved
  12. Plan Review - Fuel/Gas Approved
  13. Plan Review - Reviewed
  14. Point Review - Printed-Online Application
  15. Final Review - Payment Needed
  16. Permit Issued
  17. Permit Reissued
  18. Final Review - Payment Needed

Contractors

  • Adam Gaslin

    Maronda Homes Llc Of Florida

    License
    CRC1331630
    Title
    Cert. Residential
    Role
    Contractor

    County License & State License & Liability Insurance & Workers Comp Expired.

  • Paul K Coleman

    Colemans Plumbing Inc.

    License
    CFC1425624
    Title
    Certified Plumbing
    Role
    Subcontractor

    County License & State License & Employees Workers Comp Expired.

  • Benjamin T Keeler

    Keeler Roofing, Llc

    License
    CCC1330509
    Title
    Cert. Roofing
    Role
    Subcontractor
  • Ryan Hinote

    Nature Coast Electrical

    License
    EC13011934
    Title
    Cert. Electrical
    Role
    Subcontractor

    County License & State License & Liability Insurance & Workers Comp Expired.

  • Robert M Bounds

    Bounds Heating & Air Inc

    License
    CAC057642
    Title
    Class A A/c
    Role
    Subcontractor

Inspections

  1. Oct 17, 2024

    Passed: Plumbing/Gas - 1st Underground Rough–In

    Inspected by Matt Forsyth

  2. Oct 21, 2024

    Passed: Electrical - Temporary Service

    Inspected by Matt Forsyth

  3. Oct 21, 2024

    Release to power company

    Inspected by Matt Forsyth

  4. Oct 21, 2024

    Failed: Building - Monolithic Slab

    No Soil Pretreat

    Inspected by Matt Forsyth

  5. Oct 21, 2024

    Passed: Engineering - Setbacks

    Inspected by Matt Forsyth

  6. Oct 21, 2024

    Passed: Electrical - 1st Underground Rough–In

    Inspected by Matt Forsyth

  7. Oct 21, 2024

    Passed: Building - Monolithic Slab

    Need Document On Termite Treatment

    Inspected by Matt Forsyth

  8. Oct 21, 2024

    Passed: Engineering - Setbacks

    Inspected by Matt Forsyth

  9. Nov 4, 2024

    Passed: Building - Lintel/Tie Beam

    Inspected by Matt Forsyth

  10. Nov 4, 2024

    Passed: Building - Ext Strapping/Wall Sheathing

    Inspected by Matt Forsyth

  11. Nov 4, 2024

    Passed: Building - Wall Sheathing

    Inspected by Matt Forsyth

  12. Nov 6, 2024

    Passed: Building - Framing

    Inspected by Matt Forsyth

  13. Nov 6, 2024

    Passed: Building - Roof Decking

    Inspected by Matt Forsyth

  14. Nov 18, 2024

    Passed: Building - Framing

    Inspected by Matt Forsyth

  15. Nov 18, 2024

    Passed: Electrical - 2nd Rough-In

    Inspected by Matt Forsyth

  16. Nov 18, 2024

    Passed: Mechanical - Rough In

    Inspected by Matt Forsyth

  17. Nov 18, 2024

    Passed: Plumbing/Gas - 2nd Rough-In

    Watch Toilet Ruf watch Toilet Setbacks From Tub

    Inspected by Matt Forsyth

  18. Nov 18, 2024

    Passed: Plumbing/Gas - Tub Set/Shower Pan

    Tub Water Tested

    Inspected by Matt Forsyth

  19. Nov 19, 2024

    Passed: Building - Insulation

    Inspected by Matt Forsyth

  20. Dec 6, 2024

    Passed: Electrical - Permanent Power

    Need Septic Release - Rcv'd

    Inspected by Matt Forsyth

  21. Dec 17, 2024

    Release to power company

    Septic Rec'd

    Inspected by Melissa Garber

  22. Dec 17, 2024

    Septic Release Inspection

    Inspected by Health Dept

  23. Jan 15, 2025

    Cancelled: Building - Final

    Inspected by Matt Forsyth

  24. Jan 17, 2025

    Passed: Building - Final

    Inspected by Matt Forsyth

Documents