Columbia County is committed to ensuring accessibility to this website regardless of disability. If anyone encounters a feature on this website that is inaccessible due to a disability, please contact the County Manger’s Office and the Columbia County Board of County Commissioners at (386) 758-1005. You may also email that office at patrick_weaver@columbiacountyfla.com and provide a brief description of the inaccessible feature. The County will either correct the inaccessible feature or, if correction is not possible due to technical limitations, provide the desired information through alternative means.

Skip to content

Columbia County, FL | Permit Details

Roof Replacement or Repair Permit

Address 735 NW NOEGEL RD
LAKE CITY, FL 32055
Parcel #: 02398-308
Acres: 5.10
Owner: Keen Dallas Hart,
Subdivision: Fairfield Estates
Zoning: A-3
Flood Zone: X
District: 3
Application #: 66983
Permit #: 000050864
Related Permit:
Submitted: Monday, September 16, 2024
Issued: Thursday, September 19, 2024
Expires: Tuesday, October 22, 2024
Completed: Tuesday, October 22, 2024
Status: Completed
Septic Release? na
Notes:

Job Details
Finished floor requirement
Fema map number 12023C0260C
Type Roofing Job Replacement - Tear off Existing and Replace
Further Job Details (Explain if decking is being replaced and or Repairs are being done.) Re-roof with shingle
Type of structure House
Commercial or Residential Residential
Roof Area (for this job) Sq Ft 82
No. of Stories 1
Roof Pitch 4:12 or Greater
Is the existing roof being removed? Yes
Type of New Roofing Product Asphalt Shingles
Florida Product Approval Number FL30310-R4
Product Manufacturer IKO Industries Ltd
Product Description Asphalt Shingles- Cambridge
Building Code Edition 2023 Florida Building Code 8th Edition and 2020 National Electrical Code
Sealed roof decking options: (Must select an option.) a minimum 4-inch wide strip of selfadhering polymer-modified bitumen complying with ASTM D1970 or a minimum 3 ¾ - inch wide strip of selfadhering flexible flashing tape complying with AAMA 711, applied over all joints in the roof decking. A felt underlayment complying with ASTM D226 Type II, ASTM D4869 Type Ill or IV, or ASTM D6757, or a synthetic underlayment meeting the performance requirements specified, is required to be applied over the strips/tape over the entire roof.
Ventilation: Ridge Vent
Flashing: Replace All
Drip Edge: Replace All
Valley Treatment: Use Existing
Any cable and/or race-way wiring located on or within the roof assembly? No
Review Notes
9/9/2024 Application pending.
9/16/2024 Application submitted by applicant.
9/17/2024 Final Review - Corrections Needed
9/19/2024 Final Review - Payment Needed
9/19/2024 Permit Issued
Contractors
Name/ Business License Title Role
Shawn Raba
Done Right Roofing Inc.
Liability Insurance Expired.
CCC1333916 Cert. Roofing Contractor
Inspections
Inspection Notes Performed By Date
Passed: Re-Roof - In Progress Roof Done No In Progress Inspection Logged Troy Crews 10/18/2024
Passed: Re-Roof - Final In The Future Request In Progress Inspection Troy Crews 10/22/2024