Columbia County is committed to ensuring accessibility to this website regardless of disability. If anyone encounters a feature on this website that is inaccessible due to a disability, please contact the County Manger’s Office and the Columbia County Board of County Commissioners at (386) 758-1005. You may also email that office at patrick_weaver@columbiacountyfla.com and provide a brief description of the inaccessible feature. The County will either correct the inaccessible feature or, if correction is not possible due to technical limitations, provide the desired information through alternative means.

Skip to content

Columbia County, FL | Permit Details

Roof Replacement or Repair Permit
Address 145 SW SWEETBREEZE DR
LAKE CITY, FL 32024
Parcel #: 02433-002
Acres: 4.00
Owner: Spirit Of Christ Lutheran Church Inc
Subdivision:
Zoning: CHI
Flood Zone: X
District: 3
Application #: 66967
Permit #: 000050762
Related Permit:
Submitted: Friday, September 6, 2024
Issued: Friday, September 6, 2024
Expires: Monday, December 9, 2024
Completed: Monday, December 9, 2024
Status: Completed
Septic Release? na
Notes:

Job Details
Type Roofing Job Overlay with Metal
Type of structure Commercial Building
Commercial or Residential Commercial
Roof Area (for this job) Sq Ft 77
No. of Stories 1
Ventilation: Ridge Vent
Flashing: Use Existing
Drip Edge: Replace All
Valley Treatment: New Metal
Roof Pitch 4:12 or Greater
Any cable and/or race-way wiring located on or within the roof assembly? No
Is the existing roof being removed? No
Explain if not removing the existing roofing material? Metal over existing shingle
Type of New Roofing Product Metal
Florida Product Approval Number FL l # 17992.1 R4
Product Manufacturer CAPITAL METAL SUPPLY, INC.
Product Description Min. 29 Ga. Capital Rib Roof Panel over 1x4 Wood Purlins over 7/16” OSB
Sealed roof decking options: (Must select an option.) a minimum 4-inch wide strip of selfadhering polymer-modified bitumen complying with ASTM D1970 or a minimum 3 ¾ - inch wide strip of selfadhering flexible flashing tape complying with AAMA 711, applied over all joints in the roof decking. A felt underlayment complying with ASTM D226 Type II, ASTM D4869 Type Ill or IV, or ASTM D6757, or a synthetic underlayment meeting the performance requirements specified, is required to be applied over the strips/tape over the entire roof.
Building Code Edition 2023 Florida Building Code 8th Edition and 2020 National Electrical Code
Fema map number 12023C0290D
Review Notes
9/6/2024 Application pending.
9/6/2024 Application submitted by applicant.
9/6/2024 City of Lake City Utilities Notified. City of Lake City Notified of Application within Utility Service Areas LC_GAS, LC_WATER, LC_SEWER.
9/6/2024 Final Review - Payment Needed
9/6/2024 Permit Issued Permit # created and approved from payment.
Contractors
Name/ Business License Title Role
Inspections
Inspection Notes Performed By Date
Passed: Re-Roof - In Progress Troy Crews 11/27/2024
Passed: Re-Roof - Final Troy Crews 12/9/2024