Columbia County is committed to ensuring accessibility to this website regardless of disability. If anyone encounters a feature on this website that is inaccessible due to a disability, please contact the County Manger’s Office and the Columbia County Board of County Commissioners at (386) 758-1005. You may also email that office at patrick_weaver@columbiacountyfla.com and provide a brief description of the inaccessible feature. The County will either correct the inaccessible feature or, if correction is not possible due to technical limitations, provide the desired information through alternative means.

Skip to content

Columbia County, FL | Permit Details

New Residential Construction Permit

Address 16430 N US HIGHWAY 441
WHITE SPRINGS, FL 32096
Parcel #: 04501-006
Acres: 22.05
Owner: Beadles Lauren, Beadles Dakota
Subdivision:
Zoning: A-1
Flood Zone: X
District: 1
Application #: 66235
Permit #: 000050548
Related Permit: Right-of-Way Access/Driveway:
Submitted: Monday, July 15, 2024
Issued: Wednesday, August 14, 2024
Expires: Monday, March 17, 2025
Completed: Monday, March 17, 2025
Status: Completed
Septic Release? Yes
Notes:
**MFE= 1' ABOVE THE ROAD EXISTING MH TO BE REMOVED 30 DAYS FROM CLOSING
Job Details
Elevation regulation Minimum Requirement
Finished floor requirement One foot above the road
Fema map number 12023C0092C
This is the construction of a Single Family Dwelling
Setbacks Front 30'
Setback Side 1 25'
Setback Side 2 25'
Setbacks Rear 25'
Stories 1
Heated Area (Sqft) 2114
Total Area (Sqft) 3443
Building Code Construction Type V
Building Code Element B
Building Code Occupancy Types Residential
Occupancy Use Title single family dwelling
Building Code Edition 2023 Florida Building Code 8th Edition and 2020 National Electrical Code
Septic# (00-0000) or (X00-000) 24-0516
Sealed roof decking options. (Must select one option per FBC 2023 8th Edition) two layers of felt underlayment comply ASTM 0226 Type II or ASTM D4869 Type Ill or IV, or two layers of a synthetic underlayment meeting the performance requirements specified, lapped and fastened as specified.
Service Amps 200
Review Notes
7/15/2024 Point Review - Processing NEED * LIABILITY INSURANCE EXPIRED.
7/17/2024 Point Review - Reviewed NEED * UPDATED LIABILITY FOR TRENT * SEALED PLANS - MADE CONTACT WITH TRENT HE IS WORKING ON IT
7/18/2024 Zoning Review - On Hold-Incomplete NEED * UPDATED LIABILITY FOR TRENT * SEALED PLANS - MADE CONTACT WITH TRENT HE IS WORKING ON IT ZONING: THERE APPEARS TO BE AN EXISTING MOBILE HOME ON THE PARCEL. AG-3 ZONING ALLOWS FOR 1 DWELLING PER PARCEL. PLEASE CONTACT 386-719-1474
8/9/2024 Zoning Review - On Hold-Incomplete ZONING: THERE APPEARS TO BE AN EXISTING MOBILE HOME ON THE PARCEL. AG-3 ZONING ALLOWS FOR 1 DWELLING PER PARCEL. PLEASE CONTACT 386-719-1474
8/9/2024 Zoning Review - Reviewed ZONING: **MFE= 1' ABOVE THE ROAD EXISTING MH TO BE REMOVED 30 DAYS FROM CLOSING
8/9/2024 Plan Review - Building Approved ZONING: **MFE= 1' ABOVE THE ROAD EXISTING MH TO BE REMOVED 30 DAYS FROM CLOSING
8/9/2024 Plan Review - Electrical Approved ZONING: **MFE= 1' ABOVE THE ROAD EXISTING MH TO BE REMOVED 30 DAYS FROM CLOSING
8/9/2024 Plan Review - Mechanical Approved ZONING: **MFE= 1' ABOVE THE ROAD EXISTING MH TO BE REMOVED 30 DAYS FROM CLOSING
8/9/2024 Plan Review - Plumbing Approved ZONING: **MFE= 1' ABOVE THE ROAD EXISTING MH TO BE REMOVED 30 DAYS FROM CLOSING
8/9/2024 Plan Review - Fuel/Gas Approved ZONING: **MFE= 1' ABOVE THE ROAD EXISTING MH TO BE REMOVED 30 DAYS FROM CLOSING
8/9/2024 Plan Review - Reviewed ZONING: **MFE= 1' ABOVE THE ROAD EXISTING MH TO BE REMOVED 30 DAYS FROM CLOSING
8/13/2024 Final Review - Payment Needed
8/14/2024 Permit Issued Permit #000050548 created and approved.
1/8/2025 Final Review - Payment Needed
Contractors
Name/ Business License Title Role
Brian T Giebeig
Trent Giebeig Construction,inc.
CRC1330693 Residential Contractor Contractor
Everton D Ruddock
D&s Lighting Inc
EC13003800 Electrical Contractor Subcontractor
Derrick L Williams
D L Williams Heating & Cooling Llc
CAC1816913 Class "b" A/c Contractor Subcontractor
Kenneth R Roche
Ken Roche Plumbing Inc Dba Plumbing Now
CFC1426527 Plumbing Contractor Subcontractor
Inspections
Inspection Notes Performed By Date
Passed: Building - Footer Troy Crews 8/15/2024
Passed: Engineering - Setbacks Troy Crews 8/15/2024
Failed: Plumbing/Gas - 1st Underground Rough–In Not Ready Gary Pitzer 8/26/2024
Passed: Plumbing/Gas - 1st Underground Rough–In Gary Pitzer 8/27/2024
Passed: Building - Slab Troy Crews 9/3/2024
Passed: Building - Roof Decking Gary Pitzer 10/14/2024
Passed: Building - Wall Sheathing Gary Pitzer 10/14/2024
Passed: Building - Framing Gary Pitzer 10/17/2024
Passed: Electrical - 2nd Rough-In Troy Crews 11/8/2024
Passed: Mechanical - Rough In Troy Crews 11/8/2024
Passed: Plumbing/Gas - 2nd Rough-In Troy Crews 11/8/2024
Passed: Building - Insulation Gary Pitzer 11/14/2024
Passed: Plumbing/Gas - 1st Underground Rough–In Gary Pitzer 11/14/2024
Passed: Electrical - Temporary Service Gary Pitzer 11/14/2024
Release to power company Gary Pitzer 11/14/2024
Release to power company Melissa Garber 12/11/2024
Passed: Electrical - Permanent Power Need Septic Final Troy Crews 1/9/2025
Release to power company Septic Rec'd Melissa Garber 1/27/2025
Septic Release Inspection Health Dept 1/27/2025
Passed: Building - Final Cannot Closed Permit Or Release Certificate Of Occupancy Due To Missing Required Documents. Gary Pitzer 3/14/2025
Documents
File Name Date File Size
Power Release-release To Power Company 20250127.pdf 2025.07.05 11.57kB
Documentation 20240819 010549.pdf 2025.06.22 102.38kB
Subcontractor Form 20240819 010449.pdf 2025.06.22 237.30kB
911 Address Form 20240819 010448.pdf 2025.06.22 197.43kB
Roof Layout Plan 20240819 010647.pdf 2025.06.22 215.69kB
Product Approval Code Specifications Form 20240819 010648.pdf 2025.06.22 308.03kB
Application Information Page 20240819 010348.pdf 2025.06.22 332.62kB
Owner And Contractor Signature Page 20240819 010350.pdf 2025.06.22 381.25kB
16414 N Us Highway 441.pdf 2025.06.22 341.49kB
Blower Door Test Results 20240819 010749.pdf 2025.06.21 846.52kB
Recorded Notice Of Commencement 20240819 010349.pdf 2025.06.21 599.89kB
Septic Approval Paperwork 20240819 010447.pdf 2025.06.21 1.15MB
Residential Or Commercial Checklist 20240819 011348.pdf 2025.06.21 1.54MB
Residential Or Commercial Checklist 20240819 010547.pdf 2025.06.21 1.54MB
Truss Engineering 20240819 010748.pdf 2025.06.20 2.67MB
Win_20240903_10_13_38_pro 2024-09-03 10.15.51.738.jpg 2025.06.20 139.48kB
Energy Code Forms 20240819 010649.pdf 2025.06.20 3.47MB
Big Plans 002.pdf 2025.06.19 607.05kB
Big Plans 008.pdf 2025.06.19 937.66kB
Big Plans 005.pdf 2025.06.19 1.05MB
Big Plans 003.pdf 2025.06.19 1.09MB
Big Plans 007.pdf 2025.06.19 1.12MB
Big Plans 009.pdf 2025.06.19 1.20MB
Big Plans 006.pdf 2025.06.19 1.30MB
Big Plans 004.pdf 2025.06.19 1.36MB
Big Plans 001.pdf 2025.06.19 1.74MB
Certificate Of Occupancy 20250317.pdf 2025.03.17 102.95kB
Power Release-release To Power Company 20241211.pdf 2024.12.11 38.85kB
Power Release-electrical-temporary Service 20241114.pdf 2024.11.14 38.84kB
Original Permit 20240814.pdf 2024.08.14 46.39kB