Roof Replacement or Repair
Permit
| Application #: | 65712 |
| Permit #: |
000050471 |
| Related Permit: |
|
| Submitted: | Friday, June 7, 2024 |
| Issued: | Wednesday, July 31, 2024 |
| Expires: | Monday, January 27, 2025 |
| Completed: | |
| Status: |
Permit Issued |
| Septic Release? |
N/A |
Job Details
| Finished floor requirement |
|
| Fema map number |
12023C0513C |
| Type Roofing Job |
Replacement - Tear off Existing and Replace |
| Further Job Details (Explain if decking is being replaced and or Repairs are being done.) |
Decking replaced with new 1/2"CDX Plywood, Install new 26-gauge Standing Seam Metal Roofing System |
| Type of structure |
Storage or Garage Building |
| Commercial or Residential |
Residential |
| Roof Area (for this job) Sq Ft |
7 |
| No. of Stories |
1 |
| Roof Pitch |
2:12 to 4:12 |
| Is the existing roof being removed? |
Yes |
| Type of New Roofing Product |
Metal |
| Florida Product Approval Number |
FL#36904.2 |
| Product Manufacturer |
Tri-County Metal |
| Product Description |
26-gauge Standing Seam |
| Building Code Edition |
2023 Florida Building Code 8th Edition and 2020 National Electrical Code |
| Sealed roof decking options: (Must select an option.) |
two layers of felt underlayment comply ASTM 0226 Type II or ASTM D4869 Type Ill or IV, or two layers of a synthetic underlayment meeting the performance requirements specified, lapped and fastened as specified. |
| Ventilation: |
Ridge Vent |
| Flashing: |
Replace All |
| Drip Edge: |
Replace All |
| Valley Treatment: |
New Metal |
Review Notes
| 6/5/2024 |
Application pending. |
| 6/7/2024 |
Application submitted by applicant. |
| 6/7/2024 |
Final Review - Corrections Needed |
| 6/26/2024 |
Final Review - Payment Needed |
| 7/11/2024 |
Final Review - Payment Needed |
| 7/31/2024 |
Permit Issued |
Contractors
| Name / Business |
License |
Title |
Role |
James Brown Jim Brown Signature Roofing Inc
Liability Insurance & Workers Comp & Employees Workers Comp Expired. |
CCC1326144 |
Roofing Contractor |
Contractor |
Inspections
| Inspection |
Notes |
Performed By |
Date |