Inspection |
Notes |
Performed By |
Date |
Electrical -1st Underground Rough–In |
Electric Bond Wire Attached To Rebar |
Gary Pitzer |
8/2/2024 |
Rescheduled 8/2/2024:Building - Footer |
|
Troy Crews |
8/2/2024 |
Rescheduled 8/2/2024:Engineering - Setbacks |
|
Troy Crews |
8/2/2024 |
Passed: Building - Footer |
2#5 Rebar On Chairs Wired |
Gary Pitzer |
8/2/2024 |
Passed: Engineering - Setbacks |
Appears Within Setbacks |
Gary Pitzer |
8/2/2024 |
Passed: Plumbing/Gas - 1st Underground Rough–In |
Waste Drainage And Vents |
Gary Pitzer |
8/15/2024 |
Passed: Building - Slab |
All Perimeter Steel And Wire Mesh Aired And On Chairs, Plastic Taped |
Gary Pitzer |
8/19/2024 |
Passed: Building - Roof Decking |
|
Anthony Aslan |
9/18/2024 |
Passed: Building - Wall Sheathing |
|
Anthony Aslan |
9/18/2024 |
Cancelled: Electrical - 1st Underground Rough–In |
|
Anthony Aslan |
9/18/2024 |
Passed: Electrical - 2nd Rough-In |
|
Anthony Aslan |
9/18/2024 |
Failed: Mechanical - Rough In |
Not Complete |
Anthony Aslan |
9/18/2024 |
Failed: Plumbing/Gas - 2nd Rough-In |
Not Complete |
Anthony Aslan |
9/18/2024 |
Failed: Plumbing/Gas - Tub Set/Shower Pan |
Not Complete |
Anthony Aslan |
9/18/2024 |
Cancelled: Building - Ext Strapping/Wall Sheathing |
|
Anthony Aslan |
9/18/2024 |
Passed: Building - Framing |
|
Gary Pitzer |
9/20/2024 |
Passed: Mechanical - Rough In |
|
Gary Pitzer |
9/20/2024 |
Passed: Plumbing/Gas - 2nd Rough-In |
|
Gary Pitzer |
9/20/2024 |
Passed: Plumbing/Gas - Tub Set/Shower Pan |
|
Gary Pitzer |
9/20/2024 |
Rescheduled 9/24/2024:Electrical - Temporary Service |
|
Melissa Garber |
9/24/2024 |
Passed: Building - Insulation |
Ceiling Foamed. Walls Batted |
Gary Pitzer |
9/24/2024 |
Passed: Electrical - Temporary Service |
|
Gary Pitzer |
9/24/2024 |
Release to power company |
|
Gary Pitzer |
9/24/2024 |
Passed: Electrical - Permanent Power |
|
Gary Pitzer |
10/24/2024 |
Release to power company |
|
Gary Pitzer |
10/24/2024 |
Failed: Building - Final |
1. Complete Drives And Approval Approval, W. Need Septic Approval, 3.breaker Lock On Furnace Breaker, 3. Label Electric Panel, 4. Anti-siphon Devices On Hose Bibs, 5. Fill Voids Around Plumbing Pipes And Ac Line Sets Chase. Please Provide Photo |
Gary Pitzer |
11/8/2024 |
Passed: Building - Final |
Need Drive Way And Septic Completed |
Gary Pitzer |
12/2/2024 |
Septic Release Inspection |
|
Health Dept |
12/5/2024 |
Certificate-Release Certificate |
|
Gary Pitzer |
12/6/2024 |
Passed: City of Lake City Utilities - Lake City Utilities Tap Inspection |
|
City Of Lake City Distribution And Collections Department |
3/27/2025 |
Passed: City of Lake City Utilities - Lake City Utilities Tap Inspection |
|
City Of Lake City Distribution And Collections Department |
3/27/2025 |