Columbia County is committed to ensuring accessibility to this website regardless of disability. If anyone encounters a feature on this website that is inaccessible due to a disability, please contact the County Manger’s Office and the Columbia County Board of County Commissioners at (386) 758-1005. You may also email that office at patrick_weaver@columbiacountyfla.com and provide a brief description of the inaccessible feature. The County will either correct the inaccessible feature or, if correction is not possible due to technical limitations, provide the desired information through alternative means.

Skip to content

Columbia County, FL | Permit Details

Roof Replacement or Repair Permit
Address 518 SW WINDSOR DR
LAKE CITY, FL 32024
Parcel #: 02411-110
Acres: 2.86
Owner: Patel Sunil, Patel Pravina
Subdivision: Hills Of Windsor
Zoning: PRRD
Flood Zone: X
District: 2
Application #: 64753
Permit #: 000050375
Related Permit:
Submitted: Tuesday, July 16, 2024
Issued: Wednesday, July 17, 2024
Expires: Friday, September 6, 2024
Completed: Friday, September 6, 2024
Status: Completed
Septic Release? na
Notes:
PICS AND AFFIDAVIT REC'D
Job Details
Type Roofing Job Replacement - Tear off Existing and Replace
Further Job Details (Explain if decking is being replaced and or Repairs are being done.) Crown Tile, Batten system, TU Max underlayment
Type of structure House
Commercial or Residential Residential
Roof Area (for this job) Sq Ft 0.00
No. of Stories 2
Ventilation: Off-ridge Vent
Flashing: Repair Existing
Drip Edge: Replace All
Valley Treatment: New Metal
Roof Pitch 4:12 or Greater
Second Roof Pitch (if applicable) 2:12 to 4:12
Any cable and/or race-way wiring located on or within the roof assembly? No
Is the existing roof being removed? Yes
Type of New Roofing Product Concrete
Florida Product Approval Number FL16729-R5
Product Manufacturer Crown
Product Description Tile
Sealed roof decking options: (Must select an option.) a self-adhering polymer-modified bitumen underlayment complying with ASTM D1970 applied over the entire roof.
Sealed roof decking explanation for other option. TU Max underlayment
Building Code Edition 2023 Florida Building Code 8th Edition and 2020 National Electrical Code
Fema map number 12023C0280D
Review Notes
4/1/2024 Application pending.
7/16/2024 Application submitted by applicant.
7/16/2024 Final Review - Payment Needed
7/17/2024 Permit Issued Permit # created and approved from payment.
Contractors
Name/ Business License Title Role
Chase Massey
Massey Roofing Services Llc
CCC1332486 Cert. Roofing Contractor
Inspections
Inspection Notes Performed By Date
Passed: Re-Roof - In Progress Removing Barrel Tile Roof Installing Slate Tiles, Peal And Stick Underlayment Onsite. Troy Crews 8/21/2024
Passed: Re-Roof - Final Troy Crews 9/6/2024