Type Roofing Job |
Replacement - Tear off Existing and Replace |
Further Job Details (Explain if decking is being replaced and or Repairs are being done.) |
Remove single layer of shingles /felt to expose decking for examination, re-nail decking to meet current code as needed, Provide/Install new 8" off ridge vents to replace existing, Reuse/reseal existing metal flashing details when possible, Provide/Install new factory painted galvanized eaves drip, Provide/Install OC WeatherLock on areas where pitch is below 4in12, P/I 2 layers of OC ProArmor synthetic underlayment, P/I OC WeatherLock Mat self-adhered leak barriers in valleys, P/I OC Starter Roll at eaves,P/I OC OakRidge Architectural shingles, P/I Oentsure Heat & Moisture Ridge Vent, P/I OC ProEdge hip and ridge cap, P/I new bullet boot pipe flashings and exhaust vent flashings |
Type of structure |
Commercial Building |
Commercial or Residential |
Commercial |
Roof Area (for this job) Sq Ft |
23059 |
No. of Stories |
1 |
Ventilation: |
Ridge Vent |
Flashing: |
Use Existing |
Drip Edge: |
Replace All |
Valley Treatment: |
New Metal |
Roof Pitch |
4:12 or Greater |
Any cable and/or race-way wiring located on or within the roof assembly? |
No |
Is the existing roof being removed? |
Yes |
Type of New Roofing Product |
Asphalt Shingles |
Florida Product Approval Number |
FL10674.1 |
Product Manufacturer |
Owens Corning |
Product Description |
OC OakRidge Architectural |
Other Roofing Product Type Not Listed |
OC ProArmor Synthetic Underlayment Product Approval code 14299.1 |
Sealed roof decking options: (Must select an option.) |
two layers of felt underlayment comply ASTM 0226 Type II or ASTM D4869 Type Ill or IV, or two layers of a synthetic underlayment meeting the performance requirements specified, lapped and fastened as specified. |
Building Code Edition |
2023 Florida Building Code 8th Edition and 2020 National Electrical Code |
Fema map number |
12023C0280D |