Columbia County is committed to ensuring accessibility to this website regardless of disability. If anyone encounters a feature on this website that is inaccessible due to a disability, please contact the County Manger’s Office and the Columbia County Board of County Commissioners at (386) 758-1005. You may also email that office at patrick_weaver@columbiacountyfla.com and provide a brief description of the inaccessible feature. The County will either correct the inaccessible feature or, if correction is not possible due to technical limitations, provide the desired information through alternative means.

Skip to content

Columbia County, FL | Permit Details

Roof Replacement or Repair Permit

Address 20010 S US HIGHWAY 441
HIGH SPRINGS, FL 32643
Parcel #: 09886-000
Acres: 2.45
Owner: Hollingsworth Laura Jean
Subdivision:
Zoning: A-3
Flood Zone: X
District: 4
Application #: 66238
Permit #: 000050357
Related Permit:
Submitted: Tuesday, July 16, 2024
Issued: Tuesday, July 16, 2024
Expires: Thursday, August 1, 2024
Completed: Thursday, August 1, 2024
Status: Completed
Septic Release? na
Notes:

Job Details
Finished floor requirement
Fema map number 12023C0379C
Type Roofing Job Replacement - Tear off Existing and Replace
Type of structure Commercial Building
Commercial or Residential Commercial
Roof Area (for this job) Sq Ft 21
No. of Stories 1
Roof Pitch 4:12 or Greater
Is the existing roof being removed? Yes
Type of New Roofing Product Metal
Florida Product Approval Number 20147.1 R3
Product Manufacturer CAPITAL METAL SUPPLY
Product Description 26 Ga. Capital PBR Roof Panel over open framing
Building Code Edition 2023 Florida Building Code 8th Edition and 2020 National Electrical Code
Sealed roof decking options: (Must select an option.) a minimum 4-inch wide strip of selfadhering polymer-modified bitumen complying with ASTM D1970 or a minimum 3 ¾ - inch wide strip of selfadhering flexible flashing tape complying with AAMA 711, applied over all joints in the roof decking. A felt underlayment complying with ASTM D226 Type II, ASTM D4869 Type Ill or IV, or ASTM D6757, or a synthetic underlayment meeting the performance requirements specified, is required to be applied over the strips/tape over the entire roof.
Ventilation: Ridge Vent
Flashing: Use Existing
Drip Edge: Replace All
Valley Treatment: New Metal
Any cable and/or race-way wiring located on or within the roof assembly? No
Review Notes
7/16/2024 Application pending.
7/16/2024 Application submitted by applicant.
7/16/2024 Permit Issued Permit # created and approved from payment.
Contractors
Name/ Business License Title Role
Daniel Dufresne
Covenant Roofing & Construction Inc
CCC1332763 Cert. Roofing Contractor
Inspections
Inspection Notes Performed By Date
Passed: Re-Roof - In Progress Tear Off Anthony Aslan 7/29/2024
Passed: Re-Roof - Final Troy Crews 8/1/2024
Documents
File Name Date File Size