Columbia County is committed to ensuring accessibility to this website regardless of disability. If anyone encounters a feature on this website that is inaccessible due to a disability, please contact the County Manger’s Office and the Columbia County Board of County Commissioners at (386) 758-1005. You may also email that office at patrick_weaver@columbiacountyfla.com and provide a brief description of the inaccessible feature. The County will either correct the inaccessible feature or, if correction is not possible due to technical limitations, provide the desired information through alternative means.

Skip to content

Columbia County, FL | Permit Details

New Residential Construction Permit
Address 5133 SW PINEMOUNT RD
LAKE CITY, FL 32024
Parcel #: 00336-014
Acres: 9.24
Owner: Tessier Melodie B
Subdivision:
Zoning: A-3
Flood Zone: X
District: 2
Application #: 65651
Permit #: 000050354
Related Permit:
Submitted: Monday, June 3, 2024
Issued: Monday, July 15, 2024
Expires: Wednesday, November 20, 2024
Completed: Wednesday, November 20, 2024
Status: Completed
Septic Release? Yes
Notes:
*MFE= 1' ABOVE THE ROAD
Job Details
This is the construction of a Single Family Dwelling
Heated Area (Sqft) 1523
Total Area (Sqft) 1915
Stories 1
Building Height 17
Building Code Construction Type V
Building Code Element B
Building Code Occupancy Types Residential
Occupancy Use Title single family dwelling
Setbacks Front 30'
Setback Side 1 25'
Setback Side 2 25'
Setbacks Rear 25'
Septic# (00-0000) or (X00-000) 24-0426
Service Amps 200
Building Code Edition 2023 Florida Building Code 8th Edition and 2020 National Electrical Code
Elevation regulation Minimum Requirement
Finished floor requirement One foot above the Paved road
Fema map number 12023C0270C
Sealed roof decking options. (Must select one option per FBC 2023 8th Edition) a self-adhering polymer-modified bitumen underlayment complying with ASTM D1970 applied over the entire roof.
Review Notes
6/3/2024 Application pending.
6/3/2024 Application submitted by applicant.
6/4/2024 Point Review - On Hold-Incomplete NEEDED * GERALD M SMITH SR UPDATED STATE LICENSE LIABILITY AND WORKERS COMP * OWNER AND CONTRACTOR SIGNATURE PAGE - OWNERS SIGNATURE MUST BE WET SIGNED OR DOCUSIGNED * SIGNED SUB FORM FOR ALL TRADES * ENERGY CODES * MANUAL J * CONTRACTOR LETTER OF AUTHORIZATION FOR BRITTANY * SEALED BUILDING PLANS ***CULVERT NEEDS TO HAVE FINAL INSPECTION*** ****PRIOR TO INSPECTIONS**** RECORDED NOC
6/11/2024 Point Review - Printed-Online Application NEEDED * GERALD M SMITH SR UPDATED STATE LICENSE LIABILITY AND WORKERS COMP * OWNER AND CONTRACTOR SIGNATURE PAGE - OWNERS SIGNATURE MUST BE WET SIGNED OR DOCUSIGNED * SIGNED SUB FORM FOR ALL TRADES * ENERGY CODES * MANUAL J * CONTRACTOR LETTER OF AUTHORIZATION FOR BRITTANY ***CULVERT NEEDS TO HAVE FINAL INSPECTION*** ****PRIOR TO INSPECTIONS**** RECORDED NOC
6/12/2024 Zoning Review - Reviewed NEEDED * GERALD M SMITH SR UPDATED STATE LICENSE LIABILITY AND WORKERS COMP * OWNER AND CONTRACTOR SIGNATURE PAGE - OWNERS SIGNATURE MUST BE WET SIGNED OR DOCUSIGNED * SIGNED SUB FORM FOR ALL TRADES ZONING: *MFE= 1' ABOVE THE ROAD ***CULVERT NEEDS TO HAVE FINAL INSPECTION*** ****PRIOR TO INSPECTIONS**** RECORDED NOC
6/18/2024 Plan Review - Building Approved NEEDED * GERALD M SMITH SR UPDATED STATE LICENSE LIABILITY AND WORKERS COMP * OWNER AND CONTRACTOR SIGNATURE PAGE - OWNERS SIGNATURE MUST BE WET SIGNED OR DOCUSIGNED * SIGNED SUB FORM FOR ALL TRADES ZONING: *MFE= 1' ABOVE THE ROAD ***CULVERT NEEDS TO HAVE FINAL INSPECTION*** ****PRIOR TO INSPECTIONS**** RECORDED NOC
6/18/2024 Plan Review - Electrical Approved NEEDED * GERALD M SMITH SR UPDATED STATE LICENSE LIABILITY AND WORKERS COMP * OWNER AND CONTRACTOR SIGNATURE PAGE - OWNERS SIGNATURE MUST BE WET SIGNED OR DOCUSIGNED * SIGNED SUB FORM FOR ALL TRADES ZONING: *MFE= 1' ABOVE THE ROAD ***CULVERT NEEDS TO HAVE FINAL INSPECTION*** ****PRIOR TO INSPECTIONS**** RECORDED NOC
6/18/2024 Plan Review - Mechanical Approved NEEDED * GERALD M SMITH SR UPDATED STATE LICENSE LIABILITY AND WORKERS COMP * OWNER AND CONTRACTOR SIGNATURE PAGE - OWNERS SIGNATURE MUST BE WET SIGNED OR DOCUSIGNED * SIGNED SUB FORM FOR ALL TRADES ZONING: *MFE= 1' ABOVE THE ROAD ***CULVERT NEEDS TO HAVE FINAL INSPECTION*** ****PRIOR TO INSPECTIONS**** RECORDED NOC
6/18/2024 Plan Review - Plumbing Approved NEEDED * GERALD M SMITH SR UPDATED STATE LICENSE LIABILITY AND WORKERS COMP * OWNER AND CONTRACTOR SIGNATURE PAGE - OWNERS SIGNATURE MUST BE WET SIGNED OR DOCUSIGNED * SIGNED SUB FORM FOR ALL TRADES ZONING: *MFE= 1' ABOVE THE ROAD ***CULVERT NEEDS TO HAVE FINAL INSPECTION*** ****PRIOR TO INSPECTIONS**** RECORDED NOC
6/18/2024 Plan Review - Fuel/Gas Approved NEEDED * GERALD M SMITH SR UPDATED STATE LICENSE LIABILITY AND WORKERS COMP * OWNER AND CONTRACTOR SIGNATURE PAGE - OWNERS SIGNATURE MUST BE WET SIGNED OR DOCUSIGNED * SIGNED SUB FORM FOR ALL TRADES ZONING: *MFE= 1' ABOVE THE ROAD ***CULVERT NEEDS TO HAVE FINAL INSPECTION*** ****PRIOR TO INSPECTIONS**** RECORDED NOC
6/18/2024 Plan Review - Reviewed NEEDED * GERALD M SMITH SR UPDATED STATE LICENSE LIABILITY AND WORKERS COMP * OWNER AND CONTRACTOR SIGNATURE PAGE - OWNERS SIGNATURE MUST BE WET SIGNED OR DOCUSIGNED * SIGNED SUB FORM FOR ALL TRADES ZONING: *MFE= 1' ABOVE THE ROAD ***CULVERT NEEDS TO HAVE FINAL INSPECTION*** ****PRIOR TO INSPECTIONS**** RECORDED NOC
6/28/2024 Final Review - Documents Required NEEDED * GERALD M SMITH SR UPDATED STATE LICENSE LIABILITY AND WORKERS COMP * SIGNED SUB FORM FOR ALL TRADES ZONING: *MFE= 1' ABOVE THE ROAD ***CULVERT NEEDS TO HAVE FINAL INSPECTION*** ****PRIOR TO INSPECTIONS**** RECORDED NOC
7/1/2024 Final Review - Documents Required NEEDED * GERALD M SMITH SR UPDATED STATE LICENSE LIABILITY AND WORKERS COMP * SIGNED SUB FORM FOR ALL TRADES ZONING: *MFE= 1' ABOVE THE ROAD ***CULVERT NEEDS TO HAVE FINAL INSPECTION*** ****PRIOR TO INSPECTIONS**** RECORDED NOC
7/2/2024 Final Review - Documents Required NEEDED * SIGNED SUB FORM FOR ALL TRADES ****PRIOR TO INSPECTIONS**** RECORDED NOC
7/9/2024 Final Review - Processing NEEDED * SIGNED SUB FORM FOR ALL TRADES ****PRIOR TO INSPECTIONS**** RECORDED NOC
7/9/2024 Final Review - Corrections Needed NEEDED *PAUL KING UPDATED LIABILITY AND WORKERS COMP-- EMAIL TO BLDGINFO@COLUMBIACOUNTYFLA.COM ****PRIOR TO INSPECTIONS**** RECORDED NOC
7/9/2024 Final Review - Corrections Needed NEEDED *PAUL KING UPDATED LIABILITY AND WORKERS COMP-- EMAIL TO BLDGINFO@COLUMBIACOUNTYFLA.COM ****PRIOR TO INSPECTIONS**** RECORDED NOC - NOC SUBMITTED NOT ACCEPTABLE WE CAN ONLY ACCEPT THE FORM ON OUR WEBSITE
7/9/2024 Final Review - Payment Needed ****PRIOR TO INSPECTIONS**** RECORDED NOC - NOC SUBMITTED NOT ACCEPTABLE WE CAN ONLY ACCEPT THE FORM ON OUR WEBSITE
7/15/2024 Permit Issued Permit #000050354 created and approved.
10/22/2024 Final Review - Payment Needed
11/25/2024 Point Review - Printed-Online Application
Contractors
Name/ Business License Title Role
Gerald M Smith Sr
S&s Construction Llc
County License & State License & Liability Insurance Expired.
CBC1254161 Building Contractor Contractor
Ryan C Beville
Rbi Electrical Contracting Llc
Employees Workers Comp Expired.
EC13004236 Electrical Contractor Subcontractor
Arthur (paul) P King Jr
Pauls Heating & Air Inc
County License & State License & Liability Insurance & Workers Comp & Employees Workers Comp Expired.
CAC1813957 Cert Class B A/c Subcontractor
Brent Mccall
Suwannee Valley Plumbing Llc
CFC1432405 Cert. Plumbing Subcontractor
Benjamin T Keeler
Keeler Roofing, Llc
CCC1330509 Cert. Roofing Subcontractor
Inspections
Inspection Notes Performed By Date
Septic Release Inspection Health Dept 7/3/2024
Passed: Building - Footer Troy Crews 7/29/2024
Passed: Engineering - Setbacks Troy Crews 7/29/2024
Failed: Plumbing/Gas - 1st Underground Rough–In Flooded No Access To Job Site Access On Godbold Matt Forsyth 8/8/2024
Passed: Plumbing/Gas - 1st Underground Rough–In Cpvc Water Supply Under Slab Matt Forsyth 8/9/2024
Passed: Building - Slab Matt Forsyth 8/14/2024
Passed: Building - Ext Strapping/Wall Sheathing Matt Forsyth 8/29/2024
Passed: Building - Strapping Matt Forsyth 8/29/2024
Passed: Building - Wall Sheathing Matt Forsyth 8/29/2024
Passed: Building - Framing Matt Forsyth 9/4/2024
Passed: Electrical - 2nd Rough-In Matt Forsyth 9/4/2024
Passed: Mechanical - Rough In Matt Forsyth 9/4/2024
Passed: Plumbing/Gas - 2nd Rough-In Spigot Supply Loose In Wall Matt Forsyth 9/4/2024
Passed: Building - Insulation Matt Forsyth 9/5/2024
Release to power company Changed From Clay To Fpl Melissa Garber 10/11/2024
Passed: Electrical - Permanent Power Matt Forsyth 10/11/2024
Release to power company Matt Forsyth 10/11/2024
Certificate-Release Certificate Matt Forsyth 11/20/2024
Passed: Building - Final Cannot Closed Permit Or Release Certificate Of Occupancy Due To Missing Required Documents. Matt Forsyth 11/20/2024
Documents
File Name Date File Size
Certificate Of Occupancy 20241120.pdf 2024.11.20 68.96kB
50354 Blower Door.jpg 2024.11.20 3.39MB
50354 Pest Control.jpg 2024.11.20 2.62MB
Power Release-release To Power Company 20241011.pdf 2024.10.11 38.93kB
Power Release-electrical-permanent Power 20241011.pdf 2024.10.11 38.92kB
Win_20240814_11_36_49_pro 2024-08-14 11.38.06.399.jpg 2024.08.14 177.25kB
Original Permit 20240715.pdf 2024.07.15 46.42kB
Recorded Notice Of Commencement 20240708 135323.pdf 2024.07.08 238.24kB
Subcontractor Form 20240703 144801.pdf 2024.07.03 444.94kB
Tessier Eh 24-0426.pdf 2024.07.02 1.99MB
Reviewed Manual J Forms 65651 2024-06-18 09.24.58.275.pdf 2024.06.18 288.51kB
Reviewed Truss Engineering 65651 2024-06-18 09.24.57.572.pdf 2024.06.18 641.55kB
Reviewed Energy Code Forms 65651 2024-06-18 09.24.57.947.pdf 2024.06.18 360.00kB
Reviewed Architectural Plans 65651 2024-06-18 09.24.57.149.pdf 2024.06.18 994.68kB
Owner And Contractor Signature Page 20240614 122151.pdf 2024.06.14 194.42kB
Lidar 65651 2024-06-12 13.53.32.969.pdf 2024.06.12 155.11kB
Contractor Letter Of Authorization 20240611 103123.pdf 2024.06.11 71.13kB
Structural Engineering And Wind Load Calculations 20240611 102210.pdf 2024.06.11 4.15MB
Energy Code Forms 20240611 102115.pdf 2024.06.11 333.94kB
Manual J Forms 20240611 102115.pdf 2024.06.11 259.37kB
Owner And Contractor Signature Page 20240611 100550.pdf 2024.06.11 192.47kB
5133 Sw Pinemount Rd 2024-06-04 11.00.10.129.pdf 2024.06.04 871.41kB
Residential Or Commercial Checklist 20240603 122058.pdf 2024.06.03 937.38kB
Product Approval Code Specifications Form 20240603 122057.pdf 2024.06.03 101.33kB
Site Plan 20240603 121654.pdf 2024.06.03 48.32kB
Truss Engineering 20240603 121654.pdf 2024.06.03 550.49kB
Architectural Plans 20240603 121653.pdf 2024.06.03 965.72kB
Property Appraiser Parcel Details Printed Page 20240603 121654.pdf 2024.06.03 275.31kB
Recorded Deed 20240603 121128.pdf 2024.06.03 97.30kB