Columbia County is committed to ensuring accessibility to this website regardless of disability. If anyone encounters a feature on this website that is inaccessible due to a disability, please contact the County Manger’s Office and the Columbia County Board of County Commissioners at (386) 758-1005. You may also email that office at patrick_weaver@columbiacountyfla.com and provide a brief description of the inaccessible feature. The County will either correct the inaccessible feature or, if correction is not possible due to technical limitations, provide the desired information through alternative means.

Skip to content

Columbia County, FL | Permit Details

New Residential Construction Permit

Address 261 SW LEGACY GLN
LAKE CITY, FL 32025
Parcel #: 08466-031
Acres: 1.00
Owner: Butler Aaron B, Butler Lisa M
Subdivision: Heritage Hills Phase 2
Zoning: RSF-1
Flood Zone: X
District: 5
Application #: 65734
Permit #: 000050302
Related Permit: Right-of-Way Access/Driveway:
Submitted: Thursday, June 6, 2024
Issued: Tuesday, July 9, 2024
Expires: Sunday, May 18, 2025
Completed: Sunday, May 18, 2025
Status: Completed
Septic Release? Yes
Notes:
ZONING: ENGINEER LETTER OF MFE 12" ABOVE ADJACENT GROUND OF PERIMETER OF FOUNDATION.
LAKE CITY UTLITY CUSTOMER SERVICE NOTES The City of Lake City does not provide utilities to this location.
Job Details
Elevation regulation Engineers Elevation Letter
Finished floor requirement 12" ABOVE GRADE AT FOUNDATION
Fema map number 12023C0294D
This is the construction of a Single Family Dwelling
Setbacks Front 25'
Setback Side 1 10'
Setback Side 2 10'
Setbacks Rear 15'
Stories 1
Heated Area (Sqft) 2255
Total Area (Sqft) 3532
Building Code Construction Type V
Building Code Element B
Building Code Occupancy Types Residential
Occupancy Use Title single family dwelling
Building Code Edition 2023 Florida Building Code 8th Edition and 2020 National Electrical Code
Septic# (00-0000) or (X00-000) 24-0477
If Other, explain the use of the structure. home
Sealed roof decking options. (Must select one option per FBC 2023 8th Edition) two layers of felt underlayment comply ASTM 0226 Type II or ASTM D4869 Type Ill or IV, or two layers of a synthetic underlayment meeting the performance requirements specified, lapped and fastened as specified.
Service Amps 200
Review Notes
6/6/2024 City of Lake City Utilities Notified. City of Lake City Notified of Application within Utility Service Areas LC_GAS,.
6/10/2024 Point Review - Printed-Online Application NEED * ENVIRONMENTAL HEALTH SIGNED SITE PLAN - CONTACT 386-758-1058 **PRIOR TO INSPECTIONS** * RECORED NOC
6/10/2024 Zoning Review - Reviewed NEED * ENVIRONMENTAL HEALTH SIGNED SITE PLAN - CONTACT 386-758-1058 ZONING: ENGINEER LETTER OF MFE 12" ABOVE ADJACENT GROUND OF PERIMETER OF FOUNDATION. **PRIOR TO INSPECTIONS** * RECORED NOC
6/18/2024 Plan Review - Corrections Needed NEED **PLANS DIGITAL SEAL NOT SHOWING UP **ENERGY FORM NOT CURRENT 2023 CODE **MI WINDOW NEED UPDATED PRODUCT CODE FOR 2023 * ENVIRONMENTAL HEALTH SIGNED SITE PLAN - CONTACT 386-758-1058 ZONING: ENGINEER LETTER OF MFE 12" ABOVE ADJACENT GROUND OF PERIMETER OF FOUNDATION. **PRIOR TO INSPECTIONS** * RECORED NOC
6/20/2024 Plan Review - Corrections Needed NEED **PLANS ARE 2020, CURRENT CODE IS 2023 ZONING: RECEIVED ENGINEER LETTER OF MFE 12" ABOVE ADJACENT GROUND OF PERIMETER OF FOUNDATION. **PRIOR TO INSPECTIONS** * RECORED NOC
6/24/2024 Plan Review - Corrections Needed NEED **PLANS ARE 2020, CURRENT CODE IS 2023 ZONING: RECEIVED ENGINEER LETTER OF MFE 12" ABOVE ADJACENT GROUND OF PERIMETER OF FOUNDATION. **PRIOR TO INSPECTIONS** * RECORED NOC
6/27/2024 Plan Review - Corrections Needed NEED LETTER SENT IN 6-27-24 ELECTRONIC SEAL CAN'T BE VERIFIED **PRIOR TO INSPECTIONS** * RECORED NOC
6/27/2024 Plan Review - Plumbing Approved NEED **PRIOR TO INSPECTIONS** * RECORED NOC
6/27/2024 Plan Review - Mechanical Approved NEED **PRIOR TO INSPECTIONS** * RECORED NOC
6/27/2024 Plan Review - Electrical Approved NEED **PRIOR TO INSPECTIONS** * RECORED NOC
6/27/2024 Plan Review - Building Approved NEED **PRIOR TO INSPECTIONS** * RECORED NOC
6/27/2024 Plan Review - Reviewed NEED **PRIOR TO INSPECTIONS** * RECORED NOC
6/27/2024 Final Review - Processing NEED **PRIOR TO INSPECTIONS** * RECORED NOC
7/2/2024 Final Review - Payment Needed **PRIOR TO INSPECTIONS** * RECORED NOC
7/9/2024 Final Review - Payment Needed **PRIOR TO INSPECTIONS** * RECORED NOC
7/9/2024 Permit Issued Permit #000050302 created and approved.
5/9/2025 Final Review - Complete
Contractors
Name/ Business License Title Role
Marcus Matthews
Matthews Electric Llc
EC13005459 Electrical Contractor Subcontractor
Inspections
Inspection Notes Performed By Date
Passed: Electrical - Temporary Service Gary Pitzer 7/30/2024
Release to power company Gary Pitzer 7/30/2024
Passed: Building - Footer Gary Pitzer 8/1/2024
Passed: Engineering - Setbacks Appears To Be In Location With Setbacks Gary Pitzer 8/1/2024
Passed: Engineering - Setbacks Gary Pitzer 8/14/2024
Passed: Building - Footer Carport Area Only Gary Pitzer 8/14/2024
Passed: Plumbing/Gas - 1st Underground Rough–In Dwv, No Clean Out On Exterior Gary Pitzer 8/30/2024
Passed: Building - Slab Wire And Steel Wired Together With Plastic And Tape Gary Pitzer 9/6/2024
Passed: Electrical - 1st Underground Rough–In Under Slab Conduits Gary Pitzer 9/6/2024
Passed: Building - Roof Decking Gary Pitzer 10/14/2024
Passed: Building - Wall Sheathing Gary Pitzer 10/14/2024
Passed: Building - Framing Gary Pitzer 10/22/2024
Passed: Electrical - 2nd Rough-In Gary Pitzer 12/2/2024
Passed: Mechanical - Rough In Gary Pitzer 12/2/2024
Passed: Plumbing/Gas - 2nd Rough-In Gary Pitzer 12/2/2024
Passed: Electrical - Permanent Power Gary Pitzer 2/27/2025
Release to power company Gary Pitzer 2/27/2025
Septic Release Inspection Health Dept 3/25/2025
Failed: Building - Final Need House Address, Blower Door And Final Termite Gary Pitzer 5/9/2025
Passed: Building - Final Defects Corrected Photos Sent To File Via Email Gary Pitzer 5/12/2025
Documents
File Name Date File Size
Butler A13.pdf 2025.07.05 249.21kB
Butler A06.pdf 2025.07.05 468.51kB
Nicholas Geisler Ltr-20jun2024 2024-06-27 13.42.22.594.pdf 2025.06.22 71.82kB
65734 Site Plan Approved 2024-06-10 12.53.43.786.pdf 2025.06.22 156.91kB
City Of Lake City Approval Letter.pdf 2025.06.22 144.96kB
Elevation Certificate For Finished Construction 20240711 082748.pdf 2025.06.22 125.95kB
Documentation 20240712 112046.pdf 2025.06.22 128.91kB
Site Plan 20240711 082847.pdf 2025.06.22 179.87kB
911 Address Form 20240711 082846.pdf 2025.06.22 180.10kB
Roof Inspection Affidavit By Contractor 20240711 082948.pdf 2025.06.22 188.74kB
Butler A07.pdf 2025.06.22 229.19kB
Butler A15.pdf 2025.06.22 223.65kB
Butler A05.pdf 2025.06.22 225.52kB
Butler A02.pdf 2025.06.22 249.66kB
Product Approval Code Specifications Form 20240711 083047.pdf 2025.06.22 240.32kB
Subcontractor Form 20240711 082848.pdf 2025.06.22 257.43kB
Recorded Notice Of Commencement 20240712 112048.pdf 2025.06.22 262.98kB
Butler A12.pdf 2025.06.22 247.51kB
Application Information Page 20240711 082646.pdf 2025.06.22 281.54kB
Recorded Deed 20240711 082849.pdf 2025.06.22 275.26kB
Butler A04.pdf 2025.06.22 279.05kB
Butler A11.pdf 2025.06.22 299.51kB
Owner And Contractor Signature Page 20240711 082648.pdf 2025.06.22 351.36kB
Butler A08.pdf 2025.06.22 308.58kB
Butler A10.pdf 2025.06.22 390.28kB
Butler A09.pdf 2025.06.22 421.60kB
Subdivision Plat 20240711 082747.pdf 2025.06.22 448.76kB
Butler A14.pdf 2025.06.22 541.17kB
Septic Approval Paperwork 20240711 082747.pdf 2025.06.22 468.69kB
Butler A01.pdf 2025.06.22 585.37kB
Owner Disclosure Statement 20240711 082948.pdf 2025.06.21 765.74kB
Butler A03.pdf 2025.06.21 1.05MB
Energy Code Forms 20240711 083148.pdf 2025.06.21 1.24MB
Evevation Letter 2024-06-06 14.04.16.353.pdf 2025.06.21 1.02MB
Residential Or Commercial Checklist 20240711 082946.pdf 2025.06.21 1.48MB
Manual J Forms 20240711 083146.pdf 2025.06.20 2.62MB
50302 Final Termite Treatment.jpg 2025.06.20 268.37kB
50302 Blower Door Test.jpg 2025.06.20 503.96kB
Energy Code 2024-06-06 14.05.08.238.pdf 2025.06.19 9.04MB
Truss Engineering 20240711 083247.pdf 2025.06.19 9.91MB
Certificate Of Occupancy 20250518.pdf 2025.05.18 93.33kB
Power Release-electrical-permanent Power 20250227.pdf 2025.02.27 39.02kB
Power Release-electrical-temporary Service 20240730.pdf 2024.07.30 38.88kB
Original Permit 20240709.pdf 2024.07.09 46.00kB
Butler Eh 24-0477.pdf 2024.06.27 614.01kB