Columbia County is committed to ensuring accessibility to this website regardless of disability. If anyone encounters a feature on this website that is inaccessible due to a disability, please contact the County Manger’s Office and the Columbia County Board of County Commissioners at (386) 758-1005. You may also email that office at patrick_weaver@columbiacountyfla.com and provide a brief description of the inaccessible feature. The County will either correct the inaccessible feature or, if correction is not possible due to technical limitations, provide the desired information through alternative means.

Skip to content

Columbia County, FL | Permit Details

Roof Replacement or Repair Permit

Address 514 SW LYNNWOOD AVE
LAKE CITY, FL 32024
Parcel #: 02818-223
Acres: 0.50
Owner: Reynolds Robert T, Reynolds Kathy Ann
Subdivision: Troy Heights Unit 2
Zoning: RSF/MH-2
Flood Zone: X
District: 3
Application #: 66080
Permit #: 000050300
Related Permit:
Submitted: Monday, July 8, 2024
Issued: Tuesday, July 9, 2024
Expires: Friday, September 6, 2024
Completed: Friday, September 6, 2024
Status: Completed
Septic Release? na
Notes:

LAKE CITY UTLITY CUSTOMER SERVICE NOTES The City of Lake City does not provide utilities to this location.
Job Details
Finished floor requirement
Fema map number 12023C0290D
Type Roofing Job Re-Cover - New Material over Existing
Type of structure Mobile Home
Commercial or Residential Residential
Roof Area (for this job) Sq Ft 2600
No. of Stories 1
Roof Pitch 2:12 to 4:12
Is the existing roof being removed? No
Explain if not removing the existing roofing material? Metal over existing shingles
Type of New Roofing Product Metal
Florida Product Approval Number FL13768.1- R4
Product Manufacturer Agri Metal Supply
Product Description 26 GA Tuff Rib Roof Panel
Building Code Edition 2023 Florida Building Code 8th Edition and 2020 National Electrical Code
Sealed roof decking options: (Must select an option.) a minimum 4-inch wide strip of selfadhering polymer-modified bitumen complying with ASTM D1970 or a minimum 3 ¾ - inch wide strip of selfadhering flexible flashing tape complying with AAMA 711, applied over all joints in the roof decking. A felt underlayment complying with ASTM D226 Type II, ASTM D4869 Type Ill or IV, or ASTM D6757, or a synthetic underlayment meeting the performance requirements specified, is required to be applied over the strips/tape over the entire roof.
Ventilation: Ridge Vent
Flashing: Use Existing
Drip Edge: Use Existing
Valley Treatment: Use Existing
Any cable and/or race-way wiring located on or within the roof assembly? No
Review Notes
7/1/2024 Application pending.
7/8/2024 Application submitted by applicant.
7/8/2024 City of Lake City Utilities Notified. City of Lake City Notified of Application within Utility Service Areas LC_GAS,.
7/9/2024 Final Review - Payment Needed
7/9/2024 Permit Issued Permit # created and approved from payment.
Contractors
Name/ Business License Title Role
Roger D Whiddon
Whiddon Construction Co Inc
Workers Comp Expired.
CCC1330273 Roofing Contractor Contractor
Inspections
Inspection Notes Performed By Date
Passed: Re-Roof - Final Troy Crews 9/6/2024