Columbia County is committed to ensuring accessibility to this website regardless of disability. If anyone encounters a feature on this website that is inaccessible due to a disability, please contact the County Manger’s Office and the Columbia County Board of County Commissioners at (386) 758-1005. You may also email that office at patrick_weaver@columbiacountyfla.com and provide a brief description of the inaccessible feature. The County will either correct the inaccessible feature or, if correction is not possible due to technical limitations, provide the desired information through alternative means.

Skip to content

Columbia County, FL | Permit Details

New Residential Construction Permit
Address 701 SE TIMBERLINE RANCH GLEN
LAKE CITY, FL 32025
Parcel #: 09218-004
Acres: 11.99
Owner: Shaw Angelica C, Shaw William Seth
Subdivision:
Zoning: A-3
Flood Zone: X
District: 4
Application #: 65438
Permit #: 000050286
Related Permit: Right-of-Way Access/Driveway:
Submitted: Monday, May 20, 2024
Issued: Wednesday, July 3, 2024
Expires: Monday, January 6, 2025
Completed: Monday, January 6, 2025
Status: Completed
Septic Release? Yes
Notes:
*MFE= 1' ABOVE THE ROAD
Job Details
This is the construction of a Single Family Dwelling
Heated Area (Sqft) 2240
Total Area (Sqft) 3168
Stories 01
Building Height 9.0
Building Code Construction Type V
Building Code Element B
Building Code Occupancy Types Residential
Occupancy Use Title single family dwelling
Setbacks Front 30'
Setback Side 1 25'
Setback Side 2 25'
Setbacks Rear 25'
Septic# (00-0000) or (X00-000) 24-0504
Service Amps 225
Building Code Edition 2023 Florida Building Code 8th Edition and 2020 National Electrical Code
Elevation regulation Minimum Requirement
Finished floor requirement One foot above the road
Fema map number 12023C0405C
Sealed roof decking options. (Must select one option per FBC 2023 8th Edition) two layers of felt underlayment comply ASTM 0226 Type II or ASTM D4869 Type Ill or IV, or two layers of a synthetic underlayment meeting the performance requirements specified, lapped and fastened as specified.
Review Notes
5/20/2024 Application pending.
5/20/2024 Application submitted by applicant.
5/21/2024 Point Review - On Hold-Incomplete NEEDED * FULL APPLICANT ADDRESS - CITY STATE AND ZIP * SEALED BUILDING PLANS
6/11/2024 Point Review - Printed-Online Application NEEDED * FULL APPLICANT ADDRESS - CITY STATE AND ZIP * SIGNED SUB FORM FOR ALL TRADES * DIGITAL SIGNATURE IS NOT VERIFIABLE ON TRUSS ENGINEERING PLEASE EMAIL ORIGINAL FILE * MANUAL J & ENERGY CALCS * PRODUCT APPROVAL CODES FOR ALL EXTERIOR PRODUCTS * RESIDENTIAL CHECKLIST * SITE PLAN WITH DISTANCES FORM ALL 4 PROPERTY LINES TO PROPOSED HOME * ENVIRONMENTAL HEALTH SIGNED SITE PLAN
6/24/2024 Zoning Review - Reviewed NEEDED * FULL APPLICANT ADDRESS - CITY STATE AND ZIP * SIGNED SUB FORM FOR ALL TRADES * PRODUCT APPROVAL CODES FOR ALL EXTERIOR PRODUCTS * ENVIRONMENTAL HEALTH SIGNED SITE PLAN ZONING: *MFE= 1' ABOVE THE ROAD
6/26/2024 Plan Review - Plumbing Approved NEEDED * ENVIRONMENTAL HEALTH SIGNED SITE PLAN ZONING: *MFE= 1' ABOVE THE ROAD
6/26/2024 Plan Review - Mechanical Approved NEEDED * ENVIRONMENTAL HEALTH SIGNED SITE PLAN ZONING: *MFE= 1' ABOVE THE ROAD
6/26/2024 Plan Review - Electrical Approved NEEDED * ENVIRONMENTAL HEALTH SIGNED SITE PLAN ZONING: *MFE= 1' ABOVE THE ROAD
6/26/2024 Plan Review - Building Approved NEEDED * ENVIRONMENTAL HEALTH SIGNED SITE PLAN ZONING: *MFE= 1' ABOVE THE ROAD
6/26/2024 Plan Review - Reviewed NEEDED * ENVIRONMENTAL HEALTH SIGNED SITE PLAN ZONING: *MFE= 1' ABOVE THE ROAD
6/26/2024 Final Review - Documents Required NEEDED * ENVIRONMENTAL HEALTH SIGNED SITE PLAN ZONING: *MFE= 1' ABOVE THE ROAD
7/2/2024 Final Review - Reviewed
7/2/2024 Final Review - Payment Needed
7/3/2024 Permit Issued Permit #000050286 created and approved.
Contractors
Name/ Business License Title Role
Roger Whiddon
Lake City Plumbing Inc
CFC1428686 Cert Plumbing Subcontractor
Marcus Matthews
Matthews Electric Llc
EC13005459 Electrical Contractor Subcontractor
Robert Jarvis
Jarvis Heat And Air Llc
Workers Comp Expired.
CAC1816766 Class "b" A/c Subcontractor
William B Scott
William Scott Construction,inc.
County License & State License & Liability Insurance & Workers Comp & Employees Workers Comp Expired.
CBC1250835 Building Contractor Contractor
Roger Whiddon
Lake City Plumbing Inc
CFC1428686 Cert Plumbing Subcontractor
Inspections
Inspection Notes Performed By Date
Passed: Plumbing/Gas - 1st Underground Rough–In Dvw And Water Under Slab, Exterior Clean Out Installed Need Compaction Test For Slab Gary Pitzer 7/24/2024
Cancelled: Building - Footer Anthony Aslan 7/31/2024
Cancelled: Engineering - Setbacks Anthony Aslan 7/31/2024
Passed: Electrical - 1st Underground Rough–In Anthony Aslan 7/31/2024
Passed: Engineering - Setbacks Appears Within Setbacks Anthony Aslan 7/31/2024
Passed: Building - Monolithic Slab Anthony Aslan 7/31/2024
Passed: Building - Wall Sheathing Anthony Aslan 9/9/2024
Passed: Building - Roof Decking Anthony Aslan 9/9/2024
Cancelled: Building - Ext Strapping/Wall Sheathing Anthony Aslan 9/9/2024
Failed: Building - Framing Not Ready Anthony Aslan 9/9/2024
Cancelled: Building - Strapping Anthony Aslan 9/9/2024
Passed: Electrical - Temporary Service Anthony Aslan 9/16/2024
Release to power company Anthony Aslan 9/16/2024
Cancelled: Building - Ext Strapping/Wall Sheathing Anthony Aslan 10/1/2024
Passed: Building - Framing Anthony Aslan 10/1/2024
Passed: Building - Strapping Anthony Aslan 10/1/2024
Cancelled: Electrical - 1st Underground Rough–In Anthony Aslan 10/1/2024
Passed: Plumbing/Gas - 2nd Rough-In Anthony Aslan 10/1/2024
Passed: Mechanical - Rough In 181 On Exhaust Fan Connections Anthony Aslan 10/14/2024
Passed: Building - Insulation Spray Foam Attic, Batt In Walls Anthony Aslan 10/14/2024
Passed: Electrical - 2nd Rough-In Anthony Aslan 10/14/2024
Release to power company For Temp. Anthony Aslan 11/20/2024
Cancelled: Electrical - Permanent Power Anthony Aslan 12/26/2024
Cancelled: Building - Final Anthony Aslan 12/30/2024
Passed: Electrical - Permanent Power Needs Septic Approval, Power On At Time Of Inspection Gary Pitzer 12/30/2024
Release to power company Melissa Garber 1/3/2025
Septic Release Inspection Health Dept 1/3/2025
Certificate-Release Certificate Anthony Aslan 1/6/2025
Passed: Building - Final Cannot Closed Permit Or Release Certificate Of Occupancy Due To Missing Required Documents. Anthony Aslan 1/6/2025
Documents
File Name Date File Size
Certificate Of Occupancy 20250106.pdf 2025.01.06 62.22kB
Blower Door Test Results 20250103 162032.pdf 2025.01.03 1.92MB
Blower Door.pdf 2025.01.03 604.92kB
Power Release-release To Power Company 20250103.pdf 2025.01.03 39.02kB
Termite Certificate_final 20241231 111151.pdf 2024.12.31 245.00kB
Power Release-release To Power Company 20241120.pdf 2024.11.20 38.88kB
Power Release-electrical-temporary Service 20240916.pdf 2024.09.16 38.88kB
Truss Engineering 20240904 162559.pdf 2024.09.04 786.01kB
Structural Analysis Report 20240802 091447.pdf 2024.08.02 320.57kB
Termite Treatment_initial 20240802 091349.pdf 2024.08.02 427.73kB
Big Plans 008.pdf 2024.07.05 10.84MB
Big Plans 007.pdf 2024.07.05 13.98MB
Big Plans 006.pdf 2024.07.05 10.71MB
Big Plans 005.pdf 2024.07.05 9.77MB
Big Plans 004.pdf 2024.07.05 10.28MB
Big Plans 003.pdf 2024.07.05 10.63MB
Big Plans 002.pdf 2024.07.05 8.44MB
Big Plans 001.pdf 2024.07.05 10.35MB
Original Permit 20240703.pdf 2024.07.03 46.38kB
Shaw Eh 24-0504.pdf 2024.06.26 1.05MB
Approved Truss Plans 65438 2024-06-26 07.42.30.667.pdf 2024.06.26 1.05MB
Subcontractor Form 20240625 160533.pdf 2024.06.25 2.86MB
Manual J Forms 20240625 160533.pdf 2024.06.25 365.32kB
911 Address Form 20240625 160531.pdf 2024.06.25 5.08MB
Energy Code Forms 20240625 160533.pdf 2024.06.25 132.35kB
Product Approval Code Specifications Form 20240625 160529.pdf 2024.06.25 3.23MB
65438 Lidar 2024-06-24 16.31.24.11.pdf 2024.06.24 103.74kB
Truss Engineering 20240613 154546.pdf 2024.06.13 770.78kB
Subcontractor Form 20240613 154545.pdf 2024.06.13 1.12MB
Site Plan 20240613 154544.pdf 2024.06.13 3.69MB
Residential Or Commercial Checklist 20240613 154539.pdf 2024.06.13 8.93MB
Recorded Notice Of Commencement 20240613 154539.pdf 2024.06.13 120.39kB
Manual J Forms 20240613 154539.pdf 2024.06.13 361.62kB
Energy Code Forms 20240613 154539.pdf 2024.06.13 135.80kB
701 Se Timberline Ranch Glen 2024-06-11 16.37.00.31.pdf 2024.06.11 871.58kB
Truss Engineering 20240521 142523.pdf 2024.05.21 998.21kB
Owner And Contractor Signature Page 20240520 103833.pdf 2024.05.20 63.72kB
Recorded Deed 20240520 103834.pdf 2024.05.20 130.11kB