Columbia County is committed to ensuring accessibility to this website regardless of disability. If anyone encounters a feature on this website that is inaccessible due to a disability, please contact the County Manger’s Office and the Columbia County Board of County Commissioners at (386) 758-1005. You may also email that office at patrick_weaver@columbiacountyfla.com and provide a brief description of the inaccessible feature. The County will either correct the inaccessible feature or, if correction is not possible due to technical limitations, provide the desired information through alternative means.

Skip to content

Columbia County, FL | Permit Details

New Residential Construction Permit
Address 562 SW SEDGEFIELD FARMS GLN
FORT WHITE, FL 32038
Parcel #: 03767-325
Acres: 5.09
Owner: Owens David, Owens Kelly Ann
Subdivision: Sedgefield Phase 3
Zoning: A-3
Flood Zone: X
District: 4
Application #: 65774
Permit #: 000050280
Related Permit: Right-of-Way Access/Driveway: 000050226
Submitted: Monday, June 10, 2024
Issued: Wednesday, July 3, 2024
Expires: Monday, November 10, 2025
Completed:
Status: Permit Issued
Septic Release? No
Notes:
PLAT REQUIRES 86 FEET FINISHED FLOOR ELEVATION ELEVATION CONFIRMATION REC'D @ 90.0'
Job Details
This is the construction of a Single Family Dwelling
Heated Area (Sqft) 2057
Total Area (Sqft) 3153
Stories 1
Building Code Construction Type V
Building Code Element B
Building Code Occupancy Types Residential
Occupancy Use Title single family dwelling
Setbacks Front 30'
Setback Side 1 25'
Setback Side 2 25'
Setbacks Rear 25'
Septic# (00-0000) or (X00-000) 24-0422
Building Code Edition 2023 Florida Building Code 8th Edition and 2020 National Electrical Code
Elevation regulation Subdivision Plat
Finished floor requirement 86'
Requirement needed By Nailing Inspection
Document needed is a Surveyor letter giving the Finished Floor Elevation
Document receieved Yes
Fema map number 12023C0480C
Sealed roof decking options. (Must select one option per FBC 2023 8th Edition) two layers of felt underlayment comply ASTM 0226 Type II or ASTM D4869 Type Ill or IV, or two layers of a synthetic underlayment meeting the performance requirements specified, lapped and fastened as specified.
Review Notes
6/10/2024 Point Review - Received-Hard Copy Application NEEDED: *ENV HEALTH SIGNED SITE PLAN APPROVAL-- CONTACT 386-758-1058 OR CITY AVAILABILITY LETTER *ROOF OPTION SELECTED
6/10/2024 Zoning Review - Reviewed NEEDED: *ENV HEALTH SIGNED SITE PLAN APPROVAL-- CONTACT 386-758-1058 OR CITY AVAILABILITY LETTER *ROOF OPTION SELECTED
6/11/2024 Plan Review - Documents Required NEEDED: *ENV HEALTH SIGNED SITE PLAN APPROVAL-- CONTACT 386-758-1058 OR CITY AVAILABILITY LETTER *ROOF OPTION SELECTED TRUSS PLANS NEED TO BE 2023 CODE
6/17/2024 Plan Review - Documents Required NEEDED: *ENV HEALTH SIGNED SITE PLAN APPROVAL-- CONTACT 386-758-1058 OR CITY AVAILABILITY LETTER * TRUSS PLANS NEED TO BE 2023 CODE * DRIVEWAY APPROVAL
6/17/2024 Plan Review - Plumbing Approved NEEDED: *ENV HEALTH SIGNED SITE PLAN APPROVAL-- CONTACT 386-758-1058 OR CITY AVAILABILITY LETTER * DRIVEWAY APPROVAL SURVEYOR LETTER CONFIRMING 86 FEET OR GREATER DUE AT SLAB
6/17/2024 Plan Review - Mechanical Approved NEEDED: *ENV HEALTH SIGNED SITE PLAN APPROVAL-- CONTACT 386-758-1058 OR CITY AVAILABILITY LETTER * DRIVEWAY APPROVAL SURVEYOR LETTER CONFIRMING 86 FEET OR GREATER DUE AT SLAB
6/17/2024 Plan Review - Electrical Approved NEEDED: *ENV HEALTH SIGNED SITE PLAN APPROVAL-- CONTACT 386-758-1058 OR CITY AVAILABILITY LETTER * DRIVEWAY APPROVAL SURVEYOR LETTER CONFIRMING 86 FEET OR GREATER DUE AT SLAB
6/17/2024 Plan Review - Building Approved NEEDED: *ENV HEALTH SIGNED SITE PLAN APPROVAL-- CONTACT 386-758-1058 OR CITY AVAILABILITY LETTER * DRIVEWAY APPROVAL SURVEYOR LETTER CONFIRMING 86 FEET OR GREATER DUE AT SLAB
6/17/2024 Plan Review - Reviewed NEEDED: *ENV HEALTH SIGNED SITE PLAN APPROVAL-- CONTACT 386-758-1058 OR CITY AVAILABILITY LETTER * DRIVEWAY APPROVAL SURVEYOR LETTER CONFIRMING 86 FEET OR GREATER DUE AT SLAB
6/17/2024 Final Review - Documents Required NEEDED: *ENV HEALTH SIGNED SITE PLAN APPROVAL-- CONTACT 386-758-1058 OR CITY AVAILABILITY LETTER * DRIVEWAY APPROVAL SURVEYOR LETTER CONFIRMING 86 FEET OR GREATER DUE AT SLAB
7/1/2024 Final Review - Documents Required NEEDED: *ENV HEALTH SIGNED SITE PLAN APPROVAL-- CONTACT 386-758-1058 OR CITY AVAILABILITY LETTER * DRIVEWAY APPROVAL SURVEYOR LETTER CONFIRMING 86 FEET OR GREATER DUE AT SLAB
7/2/2024 Final Review - Reviewed SURVEYOR LETTER CONFIRMING 86 FEET OR GREATER DUE AT SLAB
7/2/2024 Final Review - Payment Needed SURVEYOR LETTER CONFIRMING 86 FEET OR GREATER DUE AT SLAB
7/3/2024 Permit Issued Permit #000050280 created and approved.
Contractors
Name/ Business License Title Role
Jonathan K Norris
Edgley Construction Of North Florida Inc
Liability Insurance Expired.
CGC1265856 Cert. Building Contractor
Donald R Hollingsworth
Holly Electric Inc
EC13005429 Electrical Subcontractor
David E Hall
David Hall's Air Cond & Heating Svc,inc.
Liability Insurance Expired.
CAC057424 Class B A/c Contractor Subcontractor
Don C Bills Sr
Hometown Plumbing Services Llc
Liability Insurance & Workers Comp & Employees Workers Comp Expired.
CFC1428890 Plumbing Contractor Subcontractor
Dana D Johnson
Mac Johnson Roofing Inc Dba Gulf Coast Metal Roofing
CCC1325497 Cert Roofing Subcontractor
Inspections
Inspection Notes Performed By Date
Passed: Plumbing/Gas - 1st Underground Rough–In Dwv Only, No Water Lines Gary Pitzer 7/19/2024
Passed: Engineering - Setbacks Gary Pitzer 7/29/2024
Passed: Building - Monolithic Slab Gary Pitzer 7/29/2024
Electrical -1st Underground Rough–In Photo On File Of Steel Footer Bond Gary Pitzer 7/30/2024
Passed: Electrical - Temporary Service Gary Pitzer 8/14/2024
Release to power company Gary Pitzer 8/14/2024
Passed: Building - Roof Decking Troy Crews 9/16/2024
Passed: Building - Wall Sheathing Troy Crews 9/16/2024
Passed: Plumbing/Gas - 2nd Rough-In Gary Pitzer 10/28/2024
Passed: Mechanical - Rough In Gary Pitzer 10/28/2024
Passed: Electrical - 2nd Rough-In Gary Pitzer 10/28/2024
Passed: Building - Framing Gary Pitzer 10/28/2024
Passed: Building - Insulation Batts In Walls And Foam Roof Gary Pitzer 11/7/2024
Passed: Electrical - Permanent Power Gary Pitzer 5/14/2025
Release to power company Gary Pitzer 5/14/2025
Documents
File Name Date File Size
Power Release-electrical-permanent Power 20250514.pdf 2025.05.14 39.13kB
Surveyor Letter Giving The Finished Floor Elevation 20240912 195753.pdf 2024.09.12 471.47kB
Power Release-electrical-temporary Service 20240814.pdf 2024.08.14 39.03kB
Steel Footer Bond 2024-07-30 13.45.20.314.jpg 2024.07.30 345.96kB
Underlayment.pdf 2024.07.17 639.78kB
Big Plans 011.pdf 2024.07.16 8.06MB
Big Plans 010.pdf 2024.07.16 15.43MB
Big Plans 009.pdf 2024.07.16 11.91MB
Big Plans 008.pdf 2024.07.16 11.50MB
Big Plans 007.pdf 2024.07.16 9.70MB
Big Plans 006.pdf 2024.07.16 10.43MB
Big Plans 005.pdf 2024.07.16 13.88MB
Big Plans 004.pdf 2024.07.16 10.32MB
Big Plans 003.pdf 2024.07.16 11.48MB
Big Plans 002.pdf 2024.07.16 8.51MB
Big Plans 001.pdf 2024.07.16 10.09MB
Owens Survey 2024-07-09 08.08.16.91.pdf 2024.07.09 346.42kB
Truss Engineering 20240703 010548.pdf 2024.07.03 33.76MB
Product Approval Code Specifications Form 20240703 010348.pdf 2024.07.03 362.37kB
Manual J Forms 20240703 010347.pdf 2024.07.03 1.90MB
Recorded Notice Of Commencement 20240703 010149.pdf 2024.07.03 677.04kB
Energy Code Forms 20240703 010147.pdf 2024.07.03 1.91MB
Residential Or Commercial Checklist 20240703 010047.pdf 2024.07.03 2.04MB
Recorded Deed 20240703 125951.pdf 2024.07.03 546.69kB
Letter 20240703 125950.pdf 2024.07.03 346.82kB
Subcontractor Form 20240703 125849.pdf 2024.07.03 364.73kB
Owner And Contractor Signature Page 20240703 125848.pdf 2024.07.03 486.58kB
Application Information Page 20240703 125752.pdf 2024.07.03 353.59kB
Original Permit 20240703.pdf 2024.07.03 46.73kB
Approved Truss Plans 65774 2024-06-17 13.53.39.944.pdf 2024.06.17 2.22MB
Owens Evh 24-0422 2024-06-13 13.03.02.904.pdf 2024.06.13 393.09kB
Elevation Map 65774.pdf 2024.06.10 149.57kB
562 Sw Sedgefield Farms Gln.pdf 2024.06.10 871.42kB
Sedgefield_phs3.pdf 2024.06.10 3.82MB