Columbia County is committed to ensuring accessibility to this website regardless of disability. If anyone encounters a feature on this website that is inaccessible due to a disability, please contact the County Manger’s Office and the Columbia County Board of County Commissioners at (386) 758-1005. You may also email that office at patrick_weaver@columbiacountyfla.com and provide a brief description of the inaccessible feature. The County will either correct the inaccessible feature or, if correction is not possible due to technical limitations, provide the desired information through alternative means.

Skip to content

Columbia County, FL | Permit Details

Roof Replacement or Repair Permit
Address 225 NW SCENIC LAKE DR
LAKE CITY, FL 32055
Parcel #: 02268-601
Acres: 1.20
Owner: Bessonoff Peter, Bessonoff Vladimir
Subdivision: Woodborough Phase 8
Zoning: RSF-2
Flood Zone: X
District: 3
Application #: 65903
Permit #: 000050232
Related Permit:
Submitted: Tuesday, June 18, 2024
Issued: Thursday, June 27, 2024
Expires: Thursday, August 15, 2024
Completed: Thursday, August 15, 2024
Status: Completed
Septic Release? na
Notes:

LAKE CITY UTLITY CUSTOMER SERVICE NOTES The City of Lake City does not provide utilities to this location.
Job Details
Type Roofing Job Replacement - Tear off Existing and Replace
Type of structure House
Commercial or Residential Residential
Roof Area (for this job) Sq Ft 5100
No. of Stories 2
Ventilation: Ridge Vent
Flashing: Use Existing
Drip Edge: Replace All
Valley Treatment: New Mineral Surface
Roof Pitch 4:12 or Greater
Is the existing roof being removed? Yes
Type of New Roofing Product Asphalt Shingles
Florida Product Approval Number FL30310-R4
Product Manufacturer IKO
Product Description Architectural
Sealed roof decking options: (Must select an option.) a minimum 4-inch wide strip of selfadhering polymer-modified bitumen complying with ASTM D1970 or a minimum 3 ¾ - inch wide strip of selfadhering flexible flashing tape complying with AAMA 711, applied over all joints in the roof decking. A felt underlayment complying with ASTM D226 Type II, ASTM D4869 Type Ill or IV, or ASTM D6757, or a synthetic underlayment meeting the performance requirements specified, is required to be applied over the strips/tape over the entire roof.
Building Code Edition 2023 Florida Building Code 8th Edition and 2020 National Electrical Code
Fema map number 12023C0280D
Review Notes
6/18/2024 Application pending.
6/18/2024 Application submitted by applicant.
6/18/2024 City of Lake City Utilities Notified. City of Lake City Notified of Application within Utility Service Areas LC_WATER,.
6/20/2024 Final Review - Corrections Needed NEEDED * OWNERS PHONE NUMBER * NOC DOES NOT MEET STATE STANDARDS - PLEASE USE THE FORM LOCATED ON OUR WEBSITE
6/24/2024 Final Review - Corrections Needed NEEDED * OWNERS PHONE NUMBER * NOC DOES NOT MEET STATE STANDARDS - PLEASE USE THE FORM LOCATED ON OUR WEBSITE
6/27/2024 Permit Issued Permit # created and approved from payment.
Contractors
Name/ Business License Title Role
Dennis Alton
Alton Roofing Services Llc
County License & State License & Workers Comp Expired.
CCC1333527 Cert. Roofing Contractor
Inspections
Inspection Notes Performed By Date
Passed: Re-Roof - In Progress Ridge Vent To He Installed. Troy Crews 8/12/2024
Passed: Re-Roof - Final Gary Pitzer 8/15/2024