4/25/2024
|
Application pending.
|
4/29/2024
|
Application submitted by applicant.
|
5/2/2024
|
Point Review - Printed-Online Application
NEEDED
* UPDATED LIABILITY FOR ROBERT M BOUNDS
* ENVIRONMENTAL HEALTH SIGNED SITE PLAN - CONTACT 386-758-1058
* MAY NEED UPDATED SUB FORM - SIGNATURES ARE NOT CLEAR **MG?**
|
5/3/2024
|
Zoning Review - Documents Required
NEEDED
* UPDATED LIABILITY FOR ROBERT M BOUNDS
* ENVIRONMENTAL HEALTH SIGNED SITE PLAN - CONTACT 386-758-1058
* MAY NEED UPDATED SUB FORM - SIGNATURES ARE NOT CLEAR **MG?**
Zoning: *for permitting. ** prior to completion.
* Proposed house is inside the floodway and will require a zero rise certificate from an engineer.
* a wetlands deliniation geological survey is needed as the proposed house is located within the wetlands.
* A permit may be required from SRWMD since it is within the floodway.
** electric company may require access to elevated meter. All utilites need to be 1 ft above BFE of 35ft.
** 2 ELEVATION CERTIFICATES WILL BE REQUIRED. UNDERCONSTRUCTION (Finished floor) AND FINAL.
|
5/9/2024
|
Zoning Review - Reviewed
NEEDED
* ENVIRONMENTAL HEALTH SIGNED SITE PLAN - CONTACT 386-758-1058
* A WETLANDS DELINIATION GEOLOGICAL SURVEY IS NEEDED AS THE PROPOSED HOUSE IS LOCATED WITHIN THE WETLANDS.
** 2 ELEVATION CERTIFICATES WILL BE REQUIRED-- PROPOSED FINISHED FLOOR (PRIOR TO PERMIT ISSUANCE) AND FINAL.
** ELECTRIC COMPANY MAY REQUIRE ACCESS TO ELEVATED METER. ALL UTILITES NEED TO BE 1 FT ABOVE BFE OF 35FT.
|
5/16/2024
|
Zoning Review - Documents Required
NEEDED
* ENVIRONMENTAL HEALTH SIGNED SITE PLAN - CONTACT 386-758-1058
* 2 ELEVATION CERTIFICATES WILL BE REQUIRED--PLAN-BASED ELEVATION AND FINAL ELEVATION.
* ELECTRIC COMPANY MAY REQUIRE ACCESS TO ELEVATED METER. METER NEEDS TO BE 1 FT ABOVE BFE OF 35FT.
* A WETLANDS DELINIATION GEOLOGICAL SURVEY IS NEEDED AS THE PROPOSED HOUSE IS LOCATED WITHIN THE WETLANDS. DOCUMENT PROVIDED ON 5/15/2024 HAS NO MEASUREMENTS. PLEASE HAVE THE SURVEYOR PLOT THE WETLANDS ON A SURVEY.
|
5/20/2024
|
Zoning Review - Documents Required
NEEDED
* ENVIRONMENTAL HEALTH SIGNED SITE PLAN - CONTACT 386-758-1058
* A WETLANDS DELINIATION GEOLOGICAL SURVEY IS NEEDED AS THE PROPOSED HOUSE IS LOCATED WITHIN THE WETLANDS. DOCUMENT PROVIDED ON 5/15/2024 HAS NO MEASUREMENTS. PLEASE HAVE THE SURVEYOR PLOT THE WETLANDS ON THE SURVEY.
* 2 ELEVATION CERTIFICATES WILL BE REQUIRED--PLAN-BASED ELEVATION AND FINAL ELEVATION.
** ELECTRIC COMPANY MAY REQUIRE ACCESS TO ELEVATED METER. METER NEEDS TO BE 1 FT ABOVE BFE OF 35FT.
|
6/5/2024
|
Zoning Review - Documents Required
NEEDED
**THE WETLANDS ARE NOW DEFINED, HOWEVER, THE PLACEMENT OF THE STRUCTURE, NAMELY THE ELEVATED DECK, IS STILL WITHIN THE REQUIRED 35’ BUFFER AREA. PLEASE RESUBMIT. THIS REVISION MAY ALSO EFFECT EC SEC C2.F AND G
*THE CONSTRUCTION BASED EC REQUIRES INFORMATION IN SECTION C2.E FOR THE PROPOSED LOWEST ELEVATION OF MACHINERY AND EQUIPMENT. (AC & ELECTRIC METER MOST LIKELY)
*THE EC SUBMITTED HAS A RAISED SEAL/SIGNATURE OF THE SURVEYOR. WE WILL NEED AN ORIGINAL COPY PRIOR TO ISSUANCE OF THE PERMIT. A SCANNED COPY CAN BE UPLOADED TO THE PERMIT PORTAL.
* 2 ELEVATION CERTIFICATES WILL BE REQUIRED--CONSTRUCTION DRAWINGS ELEVATION AND FINISHED CONSTRUCTION ELEVATION.
** ELECTRIC COMPANY MAY REQUIRE ACCESS TO ELEVATED METER. METER NEEDS TO BE 1 FT ABOVE BFE OF 35FT.
|
6/6/2024
|
Zoning Review - Reviewed
NEEDED
* FINISHED CONSTRUCTION ELEVATION PRIOR TO FINAL CO INSPECTION
** ELECTRIC COMPANY MAY REQUIRE ACCESS TO ELEVATED METER. METER NEEDS TO BE 1 FT ABOVE BFE OF 35FT.
|
6/6/2024
|
Point Review - Printed-Online Application
NEEDED
* FINISHED CONSTRUCTION ELEVATION PRIOR TO FINAL CO INSPECTION
** ELECTRIC COMPANY MAY REQUIRE ACCESS TO ELEVATED METER. METER NEEDS TO BE 1 FT ABOVE BFE OF 35FT.
|
6/12/2024
|
Plan Review - Plumbing Approved
NEEDED
* FINISHED CONSTRUCTION ELEVATION CERTIFICATE AND SURVEY PRIOR TO FINAL CO INSPECTION
** ELECTRIC COMPANY MAY REQUIRE ACCESS TO ELEVATED METER. METER NEEDS TO BE 1 FT ABOVE BFE OF 35FT.
|
6/12/2024
|
Plan Review - Mechanical Approved
NEEDED
* FINISHED CONSTRUCTION ELEVATION CERTIFICATE AND SURVEY PRIOR TO FINAL CO INSPECTION
** ELECTRIC COMPANY MAY REQUIRE ACCESS TO ELEVATED METER. METER NEEDS TO BE 1 FT ABOVE BFE OF 35FT.
|
6/12/2024
|
Plan Review - Electrical Approved
NEEDED
* FINISHED CONSTRUCTION ELEVATION CERTIFICATE AND SURVEY PRIOR TO FINAL CO INSPECTION
** ELECTRIC COMPANY MAY REQUIRE ACCESS TO ELEVATED METER. METER NEEDS TO BE 1 FT ABOVE BFE OF 35FT.
|
6/12/2024
|
Plan Review - Building Approved
NEEDED
* FINISHED CONSTRUCTION ELEVATION CERTIFICATE AND SURVEY PRIOR TO FINAL CO INSPECTION
** ELECTRIC COMPANY MAY REQUIRE ACCESS TO ELEVATED METER. METER NEEDS TO BE 1 FT ABOVE BFE OF 35FT.
|
6/12/2024
|
Plan Review - Reviewed
NEEDED
* FINISHED CONSTRUCTION ELEVATION CERTIFICATE AND SURVEY PRIOR TO FINAL CO INSPECTION
** ELECTRIC COMPANY MAY REQUIRE ACCESS TO ELEVATED METER. METER NEEDS TO BE 1 FT ABOVE BFE OF 35FT.
|
6/12/2024
|
Final Review - Processing
NEEDED
* FINISHED CONSTRUCTION ELEVATION CERTIFICATE AND SURVEY PRIOR TO FINAL CO INSPECTION
** ELECTRIC COMPANY MAY REQUIRE ACCESS TO ELEVATED METER. METER NEEDS TO BE 1 FT ABOVE BFE OF 35FT.
|
6/20/2024
|
Final Review - Reviewed
**PENDING EXISTING DRIVE VERIFICATION
|
6/25/2024
|
Final Review - Reviewed
|
6/25/2024
|
Final Review - Payment Needed
|
6/25/2024
|
Permit Issued
Permit #000050204 created and approved.
|
10/22/2024
|
Final Review - Payment Needed
|