Columbia County is committed to ensuring accessibility to this website regardless of disability. If anyone encounters a feature on this website that is inaccessible due to a disability, please contact the County Manger’s Office and the Columbia County Board of County Commissioners at (386) 758-1005. You may also email that office at patrick_weaver@columbiacountyfla.com and provide a brief description of the inaccessible feature. The County will either correct the inaccessible feature or, if correction is not possible due to technical limitations, provide the desired information through alternative means.

Skip to content

Columbia County, FL | Permit Details

New Residential Construction Permit

Address 588 SW WEATHERBY PL
LAKE CITY, FL 32024
Parcel #: 00483-118
Acres: 20.04
Owner: Gaskins Joshua E, Gaskins Tasha M
Subdivision: Ichetucknee Ridge Unr
Zoning: ESA-2
Flood Zone: X
District: 2
Application #: 65654
Permit #: 000050172
Related Permit: Right-of-Way Access/Driveway: 000050055
Submitted: Monday, June 3, 2024
Issued: Friday, June 21, 2024
Expires: Wednesday, May 21, 2025
Completed: Wednesday, May 21, 2025
Status: Completed
Septic Release? Yes
Notes:
MFE = 1' ABOVE ROAD
Job Details
Elevation regulation Minimum Requirement
Finished floor requirement One foot above the road
Fema map number 12023C0370C
This is the construction of a Single Family Dwelling
Setbacks Front 30'
Setback Side 1 25'
Setback Side 2 25'
Setbacks Rear 25'
Stories 1
Heated Area (Sqft) 2188
Total Area (Sqft) 3698
Building Height 20
Building Code Construction Type V
Building Code Element B
Building Code Occupancy Types Residential
Occupancy Use Title single family dwelling
Building Code Edition 2023 Florida Building Code 8th Edition and 2020 National Electrical Code
Septic# (00-0000) or (X00-000) 24-0483
Sealed roof decking options. (Must select one option per FBC 2023 8th Edition) two layers of felt underlayment comply ASTM 0226 Type II or ASTM D4869 Type Ill or IV, or two layers of a synthetic underlayment meeting the performance requirements specified, lapped and fastened as specified.
Service Amps 200
Review Notes
6/3/2024 Application pending.
6/3/2024 Application submitted by applicant.
6/5/2024 Point Review - Printed-Online Application
6/5/2024 Zoning Review - Reviewed
6/12/2024 Plan Review - Plumbing Approved
6/12/2024 Plan Review - Mechanical Approved
6/12/2024 Plan Review - Electrical Approved
6/12/2024 Plan Review - Building Approved
6/12/2024 Plan Review - Reviewed
6/12/2024 Final Review - Documents Required
6/17/2024 Final Review - Reviewed
6/17/2024 Final Review - Payment Needed
6/21/2024 Permit Issued
5/13/2025 Point Review - Printed-Online Application
5/21/2025 Final Review - Complete
Contractors
Name/ Business License Title Role
Joel G Buzbee
G Buzbee, Inc
Workers Comp Expired.
CGC061980 Cert General Contractor
Paul K Coleman
Colemans Plumbing Inc.
CFC1425624 Certified Plumbing Subcontractor
Donald R Davis
High Springs Electric Inc
CAC1815367 Class B A/c Subcontractor
Donald Davis
High Springs Electric Inc
EC0002306 Electrical Contractor Subcontractor
Benjamin T Keeler
Keeler Roofing, Llc
CCC1330509 Cert. Roofing Subcontractor
Inspections
Inspection Notes Performed By Date
Septic Release Inspection Health Dept 6/18/2024
Passed: Building - Footer Matt Forsyth 7/25/2024
Passed: Engineering - Setbacks Matt Forsyth 7/25/2024
Passed: Plumbing/Gas - 1st Underground Rough–In Water Supply Has Been Installed Underground Under Pressure Also Matt Forsyth 8/20/2024
Passed: Building - Slab Nice Rebar Work Matt Forsyth 8/29/2024
Passed: Building - Ext Strapping/Wall Sheathing Matt Forsyth 9/20/2024
Passed: Building - Roof Decking Matt Forsyth 9/20/2024
Passed: Building - Wall Sheathing Matt Forsyth 9/20/2024
Passed: Building - Framing Framing Is Missing Some H2 Fives On Cable Lookout Framing Members Need To Replace All Tico Nails With Three Inch Galvanized Nails On All Base Plates Matt Forsyth 9/30/2024
Failed: Building - Framing Post Were Finished With Material Could Not See 3 Inch Nails Matt Forsyth 11/22/2024
Passed: Electrical - 2nd Rough-In Matt Forsyth 11/22/2024
Failed: Mechanical - Rough In Fresh Air Return Need Duck That Is Listed On Fireplace Matt Forsyth 11/22/2024
Passed: Plumbing/Gas - 2nd Rough-In Matt Forsyth 11/22/2024
Passed: Plumbing/Gas - Tub Set/Shower Pan Shower Below Finish Floor Matt Forsyth 11/22/2024
Passed: Building - Insulation R 19 Walls R30 Partial Ceiling Wake Me Up Matt Forsyth 12/2/2024
Passed: Electrical - Permanent Power Matt Forsyth 4/3/2025
Release to power company Matt Forsyth 4/3/2025
Passed: Electrical - Permanent Power Service Entrance To Meter Can Was Placed In Different Location Matt Forsyth 4/21/2025
Release to power company Matt Forsyth 4/21/2025
Passed: Building - Final All Requirements Met-- Ok To Issue Co-- 5.21.25 Mg Matt Forsyth 5/21/2025
Documents
File Name Date File Size