Columbia County is committed to ensuring accessibility to this website regardless of disability. If anyone encounters a feature on this website that is inaccessible due to a disability, please contact the County Manger’s Office and the Columbia County Board of County Commissioners at (386) 758-1005. You may also email that office at patrick_weaver@columbiacountyfla.com and provide a brief description of the inaccessible feature. The County will either correct the inaccessible feature or, if correction is not possible due to technical limitations, provide the desired information through alternative means.

Skip to content

Columbia County, FL | Permit Details

New Residential Construction Permit

Address 215 SW BLAYLOCK CT
LAKE CITY, FL 32024
Parcel #: 03401-113
Acres: 4.01
Owner: Garcia Taylor M
Subdivision: Rivers Manor Unit 1
Zoning: A-3
Flood Zone: X
District: 5
Application #: 64903
Permit #: 000050012
Related Permit: Right-of-Way Access/Driveway: 000050007
Submitted: Monday, April 15, 2024
Issued: Friday, May 31, 2024
Expires: Friday, May 16, 2025
Completed: Friday, May 16, 2025
Status: Completed
Septic Release? Yes
Notes:
ZONING: **MFE= 1' ABOVE THE ROAD
Job Details
Finished floor requirement
Fema map number 12023C0280D
Type Roofing Job Replacement - Tear off Existing and Replace
Further Job Details (Explain if decking is being replaced and or Repairs are being done.) The current Gutters will be detach and placed back on the home after the roof is completed
Type of structure House
Commercial or Residential Residential
Roof Area (for this job) Sq Ft 35
No. of Stories 2
Roof Pitch 4:12 or Greater
Is the existing roof being removed? Yes
Type of New Roofing Product Asphalt Shingles
Florida Product Approval Number FL-18355
Product Manufacturer TAMKO
Product Description HERITAGE SHINGLE
Building Code Edition 2023 Florida Building Code 8th Edition and 2020 National Electrical Code
Sealed roof decking options: (Must select an option.) two layers of felt underlayment comply ASTM 0226 Type II or ASTM D4869 Type Ill or IV, or two layers of a synthetic underlayment meeting the performance requirements specified, lapped and fastened as specified.
Ventilation: Ridge Vent
Flashing: Use Existing
Drip Edge: Replace All
Valley Treatment: New Mineral Surface
Any cable and/or race-way wiring located on or within the roof assembly? No
Review Notes
4/15/2024 Application pending.
4/15/2024 Application submitted by applicant.
4/15/2024 Point Review - Printed-Online Application NEEDED * MCCALL TO REGISTER LICENSE CONTACT 386-758-1007 * FELKNOR UPDATED WORKERS COMP * BUCCHI UPDATED STATE LICENSE LIABILITY AND WORKERS COMP * CORRECTED RESIDENTIAL CHECKLIST (SEE EMAIL SENT ON 4/15 FOR FURTHER EXPLANATION) * 911 ADDRESS - APPLY ONLINE * SIGNED SUB FORM * ENVIRONMENTAL HEALTH SIGNED SITE PLAN - 386-758-1058
4/18/2024 Zoning Review - Reviewed NEEDED * MCCALL TO REGISTER LICENSE CONTACT 386-758-1007 * FELKNOR UPDATED WORKERS COMP * BUCCHI UPDATED STATE LICENSE LIABILITY AND WORKERS COMP * CORRECTED RESIDENTIAL CHECKLIST (SEE EMAIL SENT ON 4/15 FOR FURTHER EXPLANATION) * 911 ADDRESS - APPLY ONLINE * SIGNED SUB FORM * ENVIRONMENTAL HEALTH SIGNED SITE PLAN - 386-758-1058 ZONING: **MFE= 1' ABOVE THE ROAD
4/23/2024 Plan Review - Building Approved NEEDED * MCCALL TO REGISTER LICENSE CONTACT 386-758-1007 * FELKNOR UPDATED WORKERS COMP * BUCCHI UPDATED STATE LICENSE LIABILITY AND WORKERS COMP * CORRECTED RESIDENTIAL CHECKLIST (SEE EMAIL SENT ON 4/15 FOR FURTHER EXPLANATION) * 911 ADDRESS - APPLY ONLINE * SIGNED SUB FORM * ENVIRONMENTAL HEALTH SIGNED SITE PLAN - 386-758-1058 ZONING: **MFE= 1' ABOVE THE ROAD
4/23/2024 Plan Review - Electrical Approved NEEDED * MCCALL TO REGISTER LICENSE CONTACT 386-758-1007 * FELKNOR UPDATED WORKERS COMP * BUCCHI UPDATED STATE LICENSE LIABILITY AND WORKERS COMP * CORRECTED RESIDENTIAL CHECKLIST (SEE EMAIL SENT ON 4/15 FOR FURTHER EXPLANATION) * 911 ADDRESS - APPLY ONLINE * SIGNED SUB FORM * ENVIRONMENTAL HEALTH SIGNED SITE PLAN - 386-758-1058 ZONING: **MFE= 1' ABOVE THE ROAD
4/23/2024 Plan Review - Mechanical Approved NEEDED * MCCALL TO REGISTER LICENSE CONTACT 386-758-1007 * FELKNOR UPDATED WORKERS COMP * BUCCHI UPDATED STATE LICENSE LIABILITY AND WORKERS COMP * CORRECTED RESIDENTIAL CHECKLIST (SEE EMAIL SENT ON 4/15 FOR FURTHER EXPLANATION) * 911 ADDRESS - APPLY ONLINE * SIGNED SUB FORM * ENVIRONMENTAL HEALTH SIGNED SITE PLAN - 386-758-1058 ZONING: **MFE= 1' ABOVE THE ROAD
4/23/2024 Plan Review - Plumbing Approved NEEDED * MCCALL TO REGISTER LICENSE CONTACT 386-758-1007 * FELKNOR UPDATED WORKERS COMP * BUCCHI UPDATED STATE LICENSE LIABILITY AND WORKERS COMP * CORRECTED RESIDENTIAL CHECKLIST (SEE EMAIL SENT ON 4/15 FOR FURTHER EXPLANATION) * 911 ADDRESS - APPLY ONLINE * SIGNED SUB FORM * ENVIRONMENTAL HEALTH SIGNED SITE PLAN - 386-758-1058 ZONING: **MFE= 1' ABOVE THE ROAD
4/23/2024 Plan Review - Fuel/Gas Approved NEEDED * MCCALL TO REGISTER LICENSE CONTACT 386-758-1007 * FELKNOR UPDATED WORKERS COMP * BUCCHI UPDATED STATE LICENSE LIABILITY AND WORKERS COMP * CORRECTED RESIDENTIAL CHECKLIST (SEE EMAIL SENT ON 4/15 FOR FURTHER EXPLANATION) * 911 ADDRESS - APPLY ONLINE * SIGNED SUB FORM * ENVIRONMENTAL HEALTH SIGNED SITE PLAN - 386-758-1058 ZONING: **MFE= 1' ABOVE THE ROAD
4/23/2024 Plan Review - Reviewed NEEDED * MCCALL TO REGISTER LICENSE CONTACT 386-758-1007 * FELKNOR UPDATED WORKERS COMP * BUCCHI UPDATED STATE LICENSE LIABILITY AND WORKERS COMP * CORRECTED RESIDENTIAL CHECKLIST (SEE EMAIL SENT ON 4/15 FOR FURTHER EXPLANATION) * 911 ADDRESS - APPLY ONLINE * SIGNED SUB FORM * ENVIRONMENTAL HEALTH SIGNED SITE PLAN - 386-758-1058 ZONING: **MFE= 1' ABOVE THE ROAD
5/20/2024 Final Review - Documents Required NEEDED *DRIVEWAY APPROVAL NEEDED
5/20/2024 Final Review - Documents Required NEEDED: *ENV HEALTH SIGNED SITE PLAN APPROVAL-- CONTACT 386-758-1058 *DRIVEWAY APPROVAL NEEDED
5/23/2024 Final Review - Processing NEEDED: *DRIVEWAY APPROVAL NEEDED
5/30/2024 Final Review - Reviewed ***PRIOR TO INSPECTIONS*** RECORDED NOC
5/30/2024 Final Review - Payment Needed ***PRIOR TO INSPECTIONS*** RECORDED NOC
5/31/2024 Permit Issued Permit #000050012 created and approved.
Contractors
Name/ Business License Title Role
Donald Little
Don Little Construction & Roofing
County License & State License & Liability Insurance & Workers Comp Expired.
CGC1533509 Cert. General Contractor
Donald Little, Jr.
Don Little Construction & Roofing Inc
County License & State License & Liability Insurance & Workers Comp & Employees Workers Comp Expired.
CCC1330420 Cert. Roofing Subcontractor
Ryan Felknor
Felknor Electric, Inc.
EC13003153 Electrical Contractor Subcontractor
Lonnie T Bucchi
Ace Heat & Air Inc
Liability Insurance Expired.
CAC1817024 Cert Ac Class A Subcontractor
Brent Mccall
Suwannee Valley Plumbing Llc
Liability Insurance Expired.
CFC1432405 Cert. Plumbing Subcontractor
Inspections
Inspection Notes Performed By Date
Passed: Electrical - Temporary Service Releasing Temp Pole To The Right Side Of The Driveway. Old Service Nearest Home Site To Be Removed Gary Pitzer 6/11/2024
Release to power company Gary Pitzer 6/11/2024
Passed: Building - Footer Troy Crews 6/24/2024
Passed: Engineering - Setbacks Troy Crews 6/24/2024
Passed: Electrical - 1st Underground Rough–In Matt Forsyth 7/10/2024
Passed: Plumbing/Gas - 1st Underground Rough–In Matt Forsyth 7/10/2024
Passed: Engineering - Setbacks Gary Pitzer 7/11/2024
Passed: Building - Monolithic Slab Garage Area Only, 2 #5, Wire And Plastic Taped Gary Pitzer 7/11/2024
Passed: Building - Slab House Section, Permeter Rebar, Verticals For Future, Wire Andplastic With Tape Gary Pitzer 7/11/2024
Passed: Building - Vertical Cells/Columns Gary Pitzer 7/26/2024
Passed: Building - Masonry Wall Reinforcing Gary Pitzer 7/26/2024
Passed: Building - Roof Decking Decking Only Gary Pitzer 9/20/2024
Passed: Building - Ext Strapping/Wall Sheathing Gary Pitzer 9/30/2024
Passed: Building - Roof Decking Gary Pitzer 9/30/2024
Passed: Building - Insulation Foam On Wall With Furring Strips Gary Pitzer 9/30/2024
Cancelled: Building - Framing Neonta Anderson 10/30/2024
Passed: Electrical - 2nd Rough-In Gary Pitzer 11/1/2024
Passed: Mechanical - Rough In Gary Pitzer 11/1/2024
Passed: Plumbing/Gas - 2nd Rough-In Gary Pitzer 11/1/2024
Passed: Building - Framing Gary Pitzer 11/1/2024
Passed: Building - Insulation Matt Forsyth 11/19/2024
Passed: Electrical - Permanent Power Gary Pitzer 3/24/2025
Release to power company Gary Pitzer 3/24/2025
Passed: Building - Final Septic Release And Drive Final Required Prior To Co-- Power Should Not Have Been Released-- 5.13.25 Mg Gary Pitzer 5/12/2025
Release to power company Rec'd Septic And Final Drive Emaleigh Williams 5/16/2025
Certificate-Release Certificate Rec'd Septic And Final Drive Gary Pitzer 5/16/2025
Septic Release Inspection Health Dept 5/16/2025