Columbia County is committed to ensuring accessibility to this website regardless of disability. If anyone encounters a feature on this website that is inaccessible due to a disability, please contact the County Manger’s Office and the Columbia County Board of County Commissioners at (386) 758-1005. You may also email that office at patrick_weaver@columbiacountyfla.com and provide a brief description of the inaccessible feature. The County will either correct the inaccessible feature or, if correction is not possible due to technical limitations, provide the desired information through alternative means.

Skip to content

Columbia County, FL | Permit Details

New Residential Construction Permit

Address 749 SW COLES CT
FORT WHITE, FL 32038
Parcel #: 04145-005
Acres: 9.56
Owner: Fancher Richard,
Subdivision: Coles Unr
Zoning: A-3
Flood Zone: X
District: 2
Application #: 65119
Permit #: 000050011
Related Permit: Right-of-Way Access/Driveway:
Submitted: Tuesday, April 30, 2024
Issued: Friday, May 31, 2024
Expires: Wednesday, October 8, 2025
Completed:
Status: Permit Issued
Septic Release? Yes
Notes:
ZONING: *MFE= 1' ABOVE THE ROAD
Job Details
Elevation regulation Minimum Requirement
Finished floor requirement One foot above the road
Fema map number 12023C0490C
This is the construction of a Single Family Dwelling
Setbacks Front 35'
Setback Side 1 25'
Setback Side 2 25'
Setbacks Rear 25'
Stories 1
Heated Area (Sqft) 2432
Total Area (Sqft) 2432
Building Code Construction Type V
Building Code Element B
Building Code Occupancy Types Residential
Occupancy Use Title single family dwelling
Building Code Edition 2023 Florida Building Code 8th Edition and 2020 National Electrical Code
Septic# (00-0000) or (X00-000) 24-0344
Sealed roof decking options. (Must select one option per FBC 2023 8th Edition) two layers of felt underlayment comply ASTM 0226 Type II or ASTM D4869 Type Ill or IV, or two layers of a synthetic underlayment meeting the performance requirements specified, lapped and fastened as specified.
Service Amps 200
Review Notes
5/10/2024 Point Review - Printed-Online Application NEED * ENVIRONMENTAL HEALTH SIGNED SITE PLAN
5/13/2024 Zoning Review - Reviewed NEED * ENVIRONMENTAL HEALTH SIGNED SITE PLAN ZONING: *MFE= 1' ABOVE THE ROAD
5/20/2024 Plan Review - Building Approved NEED * ENVIRONMENTAL HEALTH SIGNED SITE PLAN ZONING: *MFE= 1' ABOVE THE ROAD
5/20/2024 Plan Review - Electrical Approved NEED * ENVIRONMENTAL HEALTH SIGNED SITE PLAN ZONING: *MFE= 1' ABOVE THE ROAD
5/20/2024 Plan Review - Mechanical Approved NEED * ENVIRONMENTAL HEALTH SIGNED SITE PLAN ZONING: *MFE= 1' ABOVE THE ROAD
5/20/2024 Plan Review - Plumbing Approved NEED * ENVIRONMENTAL HEALTH SIGNED SITE PLAN ZONING: *MFE= 1' ABOVE THE ROAD
5/20/2024 Plan Review - Fuel/Gas Approved NEED * ENVIRONMENTAL HEALTH SIGNED SITE PLAN ZONING: *MFE= 1' ABOVE THE ROAD
5/20/2024 Plan Review - Reviewed NEED * ENVIRONMENTAL HEALTH SIGNED SITE PLAN ZONING: *MFE= 1' ABOVE THE ROAD
5/22/2024 Final Review - Documents Required NEED *ENVIRONMENTAL HEALTH SIGNED SITE PLAN *SIGNED SUBFORM ZONING: *MFE= 1' ABOVE THE ROAD
5/23/2024 Final Review - Documents Required NEED *ENVIRONMENTAL HEALTH SIGNED SITE PLAN-- X # NOT SUFFICIENT DUE TO ONLY BEING RELEASED FOR A WELL *SIGNED SUBFORM ZONING: *MFE= 1' ABOVE THE ROAD
5/23/2024 Final Review - Documents Required NEED *SIGNED SUBFORM ZONING: *MFE= 1' ABOVE THE ROAD
5/28/2024 Final Review - Reviewed
5/28/2024 Final Review - Payment Needed
5/31/2024 Permit Issued Permit #000050011 created and approved.
Contractors
Name/ Business License Title Role
Inspections
Inspection Notes Performed By Date
Failed: Building - Slab Not Ready Anthony Aslan 7/16/2024
Passed: Plumbing/Gas - 1st Underground Rough–In Anthony Aslan 7/16/2024
Septic Release Inspection Health Dept 7/19/2024
Passed: Building - Footer Anthony Aslan 7/26/2024
Passed: Engineering - Setbacks Appears Within Setbacks Anthony Aslan 7/26/2024
Failed: Building - Roof Decking Nail Embedded In Sheathing Same For Walls Anthony Aslan 8/22/2024
Passed: Building - Roof Decking Anthony Aslan 8/29/2024
Passed: Building - Wall Sheathing Renailed Anthony Aslan 8/29/2024
Cancelled: Electrical - 1st Underground Rough–In Anthony Aslan 2/20/2025
Passed: Electrical - 2nd Rough-In Anthony Aslan 2/20/2025
Failed: Building - Framing Need Screw On King Wall Studs Anthony Aslan 2/20/2025
Passed: Building - Framing Check Studs Missing Screws On Any Other Inspections Anthony Aslan 4/11/2025
Documents
File Name Date File Size
65119 Lidar Site Plan 2024-05-13 12.29.16.884.pdf 2025.06.22 151.85kB
Roof Inspection Affidavit By Contractor 20240604 092449 2024-06-04 09.53.17.229.pdf 2025.06.22 202.53kB
Application Information Page 20240604 091848 2024-06-04 09.53.21.434.pdf 2025.06.22 211.32kB
Recorded Notice Of Commencement 20240604 092450 2024-06-04 09.53.18.448.pdf 2025.06.22 218.67kB
Blower Door Test Results 20240604 092648 2024-06-04 09.53.21.90.pdf 2025.06.22 281.31kB
Subcontractor Form 20240604 092350 2024-06-04 09.53.16.120.pdf 2025.06.22 212.57kB
Owner And Contractor Signature Page 20240604 092248 2024-06-04 09.53.19.526.pdf 2025.06.22 354.39kB
Termite Treatment_initial 20240729 095247.pdf 2025.06.22 340.68kB
Site Plan 20240604 092348 2024-06-04 09.53.16.792.pdf 2025.06.22 340.57kB
S.1.pdf 2025.06.22 449.16kB
Site Plan 2024-05-10 12.39.38.125.pdf 2025.06.22 204.55kB
Reviewed S.1 65119 2024-05-20 13.31.19.309.pdf 2025.06.22 452.73kB
Sub Form 2024-05-23 13.12.22.949.pdf 2025.06.22 250.85kB
S.4.pdf 2025.06.22 580.20kB
Reviewed S.4 65119 2024-05-20 13.31.17.953.pdf 2025.06.21 588.86kB
Owner Disclosure Statement 20240604 092448 2024-06-04 09.53.19.917.pdf 2025.06.21 733.50kB
Manual J Forms 20240604 092650 2024-06-04 09.53.20.481.pdf 2025.06.21 847.48kB
S.2.pdf 2025.06.21 930.40kB
Reviewed S.2 65119 2024-05-20 13.31.18.856.pdf 2025.06.21 933.93kB
Product Approval Code Specifications Form 20240604 092648 2024-06-04 09.53.18.839.pdf 2025.06.21 1.01MB
S.3.pdf 2025.06.21 978.68kB
Architectural Plans 2024-04-30 09.39.48.374.pdf 2025.06.21 946.72kB
Reviewed S.3 65119 2024-05-20 13.31.18.356.pdf 2025.06.21 984.59kB
Reviewed Architectural Plans 65119 2024-05-20 13.31.37.590.pdf 2025.06.21 973.20kB
Residential Or Commercial Checklist 20240604 092548 2024-06-04 09.53.17.651.pdf 2025.06.21 1.60MB
Original Permit 20240531.pdf 2024.05.31 43.67kB
Fancher Eh 24-0344.pdf 2024.05.23 514.72kB
Columbia County Property Appraiser 2024-05-10 12.32.05.272.pdf 2024.05.10 916.04kB