Permit Details

Permit Search

Permit

New Residential Construction

979 SW HUNTER RD
LAKE CITY, FL 32024

Permit #
000049966
Application #
64537
Status Completed
  1. Submitted Mar 19, 2024
  2. Issued May 28, 2024
  3. Expires Jul 20, 2025
  4. Completed Jan 23, 2025

Property

Parcel #
02417-003
Owner
Dougherty Mccartney C, Granite Carla J
Acres
1.87
Subdivision
—
Zoning
A-3
Flood zone
X
District
2

Permit

Status
Completed
Septic release
Released
Related permit
—

Job Details

Elevation regulation
Minimum Requirement
Finished floor requirement
One foot above the road
Fema map number
12023C0270C
This is the construction of a
Single Family Dwelling
Setbacks Front
30'
Setback Side 1
25'
Setback Side 2
25'
Setbacks Rear
25'
Stories
1
Heated Area (Sqft)
1915
Total Area (Sqft)
2443
Building Height
15
Building Code Construction Type
V
Building Code Element
B
Building Code Occupancy Types
Residential
Occupancy Use Title
single family dwelling
Building Code Edition
2023 Florida Building Code 8th Edition and 2020 National Electrical Code
Septic# (00-0000) or (X00-000)
24-0141
Sealed roof decking options. (Must select one option per FBC 2023 8th Edition)
a minimum 4-inch wide strip of selfadhering polymer-modified bitumen complying with ASTM D1970 or a minimum 3 ¾ - inch wide strip of selfadhering flexible flashing tape complying with AAMA 711, applied over all joints in the roof decking. A felt underlayment complying with ASTM D226 Type II, ASTM D4869 Type Ill or IV, or ASTM D6757, or a synthetic underlayment meeting the performance requirements specified, is required to be applied over the strips/tape over the entire roof.
Service Amps
200

Status & Review History

  1. Application pending.
  2. Application submitted by applicant.
  3. Point Review - Printed-Online Application
  4. Plan Review - Documents Required
  5. Plan Review - Building Approved
  6. Plan Review - Electrical Approved
  7. Plan Review - Mechanical Approved
  8. Plan Review - Plumbing Approved
  9. Plan Review - Fuel/Gas Approved
  10. Plan Review - Reviewed
  11. Zoning Review - Reviewed
  12. Plan Review - Documents Required
  13. Plan Review - Documents Required
  14. Plan Review - Documents Required
  15. Plan Review - Documents Required
  16. Plan Review - Documents Required
  17. Plan Review - Documents Required
  18. Plan Review - Documents Required
  19. Plan Review - Documents Required
  20. Plan Review - Plumbing Approved
  21. Plan Review - Mechanical Approved
  22. Plan Review - Electrical Approved
  23. Plan Review - Building Approved
  24. Plan Review - Reviewed
  25. Final Review - Processing
  26. Final Review - Processing
  27. Final Review - Processing
  28. Final Review - Payment Needed
  29. Permit Issued
  30. Final Review - Payment Needed

Contractors

  • Bryan Zecher

    Bryan Zecher Homes Inc

    License
    CBC1257343
    Title
    Building Contractor
    Role
    Contractor
  • Cody Barrs

    Barrs Plumbing Inc

    License
    CFC1427145
    Title
    Plumbing Contractor
    Role
    Subcontractor
  • Robert Ogles

    Ogles Roofing & Construction Llc

    License
    CCC1328699
    Title
    Cert Roofing
    Role
    Subcontractor

    County License & State License Expired.

  • Donald R Hollingsworth

    Holly Electric Inc

    License
    EC13005429
    Title
    Electrical
    Role
    Subcontractor
  • Anthony R Franks

    Lane Heating & Air Llc

    License
    CAC1818631
    Title
    Cert. A/c Class “b”
    Role
    Subcontractor

    County License & State License Expired.

Inspections

  1. May 31, 2024

    Passed: Building - Footer

    Need Notice Of Commencement Posted Along With The Permit

    Inspected by Matt Forsyth

  2. May 31, 2024

    Passed: Engineering - Setbacks

    Inspected by Matt Forsyth

  3. Jun 20, 2024

    Passed: Plumbing/Gas - 1st Underground Rough–In

    Inspected by Matt Forsyth

  4. Jul 3, 2024

    Passed: Building - Slab

    Inspected by Troy Crews

  5. Jul 25, 2024

    Release to power company

    Power Company Changed From Clay To Fpl

    Inspected by Melissa Garber

  6. Jul 25, 2024

    Passed: Electrical - Temporary Service

    Inspected by Matt Forsyth

  7. Jul 25, 2024

    Release to power company

    Inspected by Matt Forsyth

  8. Jul 29, 2024

    Passed: Building - Wall Sheathing

    Roof Sheathing Also Passed Inspection

    Inspected by Matt Forsyth

  9. Aug 27, 2024

    Release to power company

    Inspected by Melissa Garber

  10. Aug 30, 2024

    Passed: Electrical - 2nd Rough-In

    Inspected by Matt Forsyth

  11. Aug 30, 2024

    Passed: Mechanical - Rough In

    Inspected by Matt Forsyth

  12. Aug 30, 2024

    Passed: Plumbing/Gas - 2nd Rough-In

    Inspected by Matt Forsyth

  13. Aug 30, 2024

    Failed: Building - Framing

    Truss Hanger Nails Not Right Size. Post Base Should Be 3 Inch Hand Driven Nails

    Inspected by Matt Forsyth

  14. Sep 13, 2024

    Passed: Building - Insulation

    Inspected by Troy Crews

  15. Nov 22, 2024

    Failed: Electrical - Permanent Power

    Electrical Work Is Not Ready For Inspection Please Resubmit After Work Is Complete

    Inspected by Matt Forsyth

  16. Nov 25, 2024

    Passed: Electrical - Permanent Power

    Septic Needed

    Inspected by Matt Forsyth

  17. Dec 2, 2024

    Septic Release Inspection

    Inspected by Health Dept

  18. Dec 3, 2024

    Release to power company

    Rec'd Septic

    Inspected by Matt Forsyth

  19. Jan 21, 2025

    Passed: Building - Final

    Cannot Closed Permit Or Release Certificate Of Occupancy Due To Missing Required Documents.

    Inspected by Matt Forsyth

  20. Jan 23, 2025

    Certificate-Release Certificate

    Inspected by Matt Forsyth

Documents