Columbia County is committed to ensuring accessibility to this website regardless of disability. If anyone encounters a feature on this website that is inaccessible due to a disability, please contact the County Manger’s Office and the Columbia County Board of County Commissioners at (386) 758-1005. You may also email that office at patrick_weaver@columbiacountyfla.com and provide a brief description of the inaccessible feature. The County will either correct the inaccessible feature or, if correction is not possible due to technical limitations, provide the desired information through alternative means.

Skip to content

Columbia County, FL | Permit Details

New Residential Construction Permit
Address 179 SE TRISTIN LN
LAKE CITY, FL 32025
Parcel #: 07018-401
Acres: 0.19
Owner: Cannon Brian P
Subdivision: Eastside Village Unit 4
Zoning: RMF-1
Flood Zone: X
District: 4
Application #: 64539
Permit #: 000049841
Related Permit: Right-of-Way Access/Driveway:
Submitted: Wednesday, March 13, 2024
Issued: Friday, May 17, 2024
Expires: Thursday, December 12, 2024
Completed: Thursday, December 12, 2024
Status: Completed
Septic Release? Yes
Notes:
*MFE= 1' ABOVE THE ROAD
LAKE CITY UTLITY CUSTOMER SERVICE NOTES The Utility Department approved the tap application this location.
Job Details
This is the construction of a Single Family Dwelling
Heated Area (Sqft) 1213
Total Area (Sqft) 1533
Stories 1
Building Height 16
Building Code Construction Type V
Building Code Element B
Building Code Occupancy Types Residential
Occupancy Use Title single family dwelling
Setbacks Front 20'
Setback Side 1 10'
Setback Side 2 10'
Setbacks Rear 15'
Septic# (00-0000) or (X00-000) x-city
Service Amps 200
Building Code Edition 2023 Florida Building Code 8th Edition and 2020 National Electrical Code
Elevation regulation Minimum Requirement
Finished floor requirement One foot above the road
Fema map number 12023C0311D
Sealed roof decking options. (Must select one option per FBC 2023 8th Edition) two layers of felt underlayment comply ASTM 0226 Type II or ASTM D4869 Type Ill or IV, or two layers of a synthetic underlayment meeting the performance requirements specified, lapped and fastened as specified.
Review Notes
3/12/2024 Application pending.
3/13/2024 Application submitted by applicant.
3/13/2024 City of Lake City Utilities Notified. City of Lake City Notified of Application within Utility Service Areas LC_GAS, LC_WATER, LC_SEWER.
3/14/2024 Point Review - Printed-Online Application NEEDED * UPDATED LIABILITY FOR WILLIAM J CASON * JUSTIN MCCULLORS NEEDS TO MAKE PAYMENT TO COMPLETE REGISTRATION * UPDATED LIABITY AND WORKERS COMP FOR CHARLES E NEWMAN * IT APPEARS PAGES ARE MISSING FROM TRUSS ENGINEERING * RESIDENTIAL CHECKLIST * SIGNED SUB FORM FOR ALL TRADES
3/21/2024 Plan Review - Corrections Needed NEEDED **TRUSS ENGINEERING ONLY 1 PAGE **ENERGY FORMS ONLY 1 PAGE * UPDATED LIABILITY FOR WILLIAM J CASON * JUSTIN MCCULLORS NEEDS TO MAKE PAYMENT TO COMPLETE REGISTRATION * UPDATED LIABITY AND WORKERS COMP FOR CHARLES E NEWMAN * IT APPEARS PAGES ARE MISSING FROM TRUSS ENGINEERING * RESIDENTIAL CHECKLIST * SIGNED SUB FORM FOR ALL TRADES
3/27/2024 Plan Review - Documents Required NEEDED * JUSTIN MCCULLORS NEEDS TO MAKE PAYMENT TO COMPLETE REGISTRATION * RESIDENTIAL CHECKLIST * SIGNED SUB FORM FOR ALL TRADES
3/27/2024 Plan Review - Building Approved NEEDED * JUSTIN MCCULLORS NEEDS TO MAKE PAYMENT TO COMPLETE REGISTRATION * RESIDENTIAL CHECKLIST * SIGNED SUB FORM FOR ALL TRADES
3/27/2024 Plan Review - Electrical Approved NEEDED * JUSTIN MCCULLORS NEEDS TO MAKE PAYMENT TO COMPLETE REGISTRATION * RESIDENTIAL CHECKLIST * SIGNED SUB FORM FOR ALL TRADES
3/27/2024 Plan Review - Mechanical Approved NEEDED * JUSTIN MCCULLORS NEEDS TO MAKE PAYMENT TO COMPLETE REGISTRATION * RESIDENTIAL CHECKLIST * SIGNED SUB FORM FOR ALL TRADES
3/27/2024 Plan Review - Plumbing Approved NEEDED * JUSTIN MCCULLORS NEEDS TO MAKE PAYMENT TO COMPLETE REGISTRATION * RESIDENTIAL CHECKLIST * SIGNED SUB FORM FOR ALL TRADES
3/27/2024 Plan Review - Fuel/Gas Approved NEEDED * JUSTIN MCCULLORS NEEDS TO MAKE PAYMENT TO COMPLETE REGISTRATION * RESIDENTIAL CHECKLIST * SIGNED SUB FORM FOR ALL TRADES
3/27/2024 Plan Review - Reviewed NEEDED * JUSTIN MCCULLORS NEEDS TO MAKE PAYMENT TO COMPLETE REGISTRATION * RESIDENTIAL CHECKLIST * SIGNED SUB FORM FOR ALL TRADES
3/28/2024 Zoning Review - Reviewed NEEDED * RESIDENTIAL CHECKLIST * CHARLES E NEWMAN WILL NEED TO SIGN SUB FORM AS CHARLES NEW MAN - *MFE= 1' ABOVE THE ROAD
4/3/2024 Final Review - Documents Required NEEDED: *ENV HEALTH APPROVAL OR CITY OF LAKE CITY AVAILABILITY LETTER *CORRECT ESTIMATED COST
4/17/2024 Final Review - Documents Required NEEDED: *CITY OF LAKE CITY AVAILABILITY LETTER-- CONTACT SHASTA TO COMPLETE TAP APPLICATION IF TAPPING INTO CITY UTILITIES (386-719-5750)-- OR ENV HEALTH SIGNED SITE PLAN APPROVAL (386-758-1058)
4/24/2024 Final Review - Documents Required NEEDED: *CITY OF LAKE CITY AVAILABILITY LETTER-- CONTACT SHASTA TO COMPLETE TAP APPLICATION IF TAPPING INTO CITY UTILITIES (386-719-5750)-- OR ENV HEALTH SIGNED SITE PLAN APPROVAL (386-758-1058)
5/14/2024 Final Review - Processing *PENDING DRIVE APPROVAL FOR EXISTING PRIVATE DRIVE
5/16/2024 Final Review - Reviewed
5/16/2024 Final Review - Payment Needed ***PRIOR TO INSPECTIONS*** RECORDED NOC
5/17/2024 Permit Issued Permit #000049841 created and approved.
Contractors
Name/ Business License Title Role
William J Cason
Cason Builders,inc.
County License & State License & Workers Comp Expired.
CBC060151 Building Contractor Contractor
Justin Mccullors
M&r Plumbing Inc
County License & State License & Liability Insurance & Workers Comp Expired.
CFC1429143 Cert. Plumbing Subcontractor
William P Duffield
Duffield Home Improvement
CCC1325785 Roofing Contractor Subcontractor
Kyle Ahrens
Custom Design Solutions Inc Dba Redline Electric
EC13008087 Cert. Electrical Subcontractor
Charles E Newman
Newmans Heating & Air Cond.,inc.
County License & State License & Liability Insurance & Workers Comp Expired.
CAC058422 Class B A/c Subcontractor
Inspections
Inspection Notes Performed By Date
Passed: Electrical - Temporary Service Anthony Aslan 6/5/2024
Release to power company Anthony Aslan 6/5/2024
Passed: Building - Footer Anthony Aslan 7/15/2024
Passed: Engineering - Setbacks Appears To Be Within Setbacks, Tight Lot Lines Anthony Aslan 7/15/2024
Passed: Plumbing/Gas - 1st Underground Rough–In Anthony Aslan 8/2/2024
Passed: Building - Slab Anthony Aslan 8/14/2024
Passed: Building - Roof Decking Anthony Aslan 8/27/2024
Passed: Building - Wall Sheathing Anthony Aslan 8/27/2024
Passed: Building - Framing Anthony Aslan 8/29/2024
Passed: Building - Strapping Anthony Aslan 8/29/2024
Passed: Electrical - 2nd Rough-In Anthony Aslan 9/12/2024
Passed: Mechanical - Rough In Anthony Aslan 9/12/2024
Passed: Plumbing/Gas - 2nd Rough-In Anthony Aslan 9/12/2024
Passed: Plumbing/Gas - Tub Set/Shower Pan Anthony Aslan 9/12/2024
Passed: Building - Insulation Insulation Missing Over Front Door Send Pic Anthony Aslan 9/18/2024
Passed: Electrical - Permanent Power Anthony Aslan 10/28/2024
Release to power company Anthony Aslan 10/28/2024
Certificate-Release Certificate Troy Crews 12/12/2024
Passed: Building - Final Cannot Closed Permit Or Release Certificate Of Occupancy Due To Missing Required Documents. Troy Crews 12/12/2024
Documents
File Name Date File Size
Certificate Of Occupancy 20241212.pdf 2024.12.12 54.47kB
Revised Envelope Leakage Test Report (blower Door Test) 49841 2024-12-05 08.09.54.553.pdf 2024.12.05 2.84MB
Power Release-electrical-permanent Power 20241028.pdf 2024.10.28 39.02kB
Structural Analysis Report 20240815 082547.pdf 2024.08.15 338.26kB
Termite Treatment_initial 20240815 082548.pdf 2024.08.15 168.92kB
City Of Lake City Approval Letter.pdf 2024.06.21 185.74kB
Power Release-electrical-temporary Service 20240605.pdf 2024.06.05 38.89kB
Notice Of Commencement Recorded Cannon 2024-06-04 16.47.47.403.pdf 2024.06.04 514.15kB
Original Permit 20240517.pdf 2024.05.17 46.54kB
Lake City Utility Service Verification Documents 20240507 163517.pdf 2024.05.07 61.10kB
Electrical, Plumbing, And Roofing Subform.pdf 2024.04.03 2.42MB
Mechanical Subform.pdf 2024.04.03 91.64kB
Residential Or Commercial Checklist 20240331 151844.pdf 2024.03.31 4.05MB
64539 Lidar 2024-03-28 12.20.43.438.pdf 2024.03.28 90.97kB
Reviewed Truss Engineering 64539 2024-03-27 14.08.48.160.pdf 2024.03.27 614.84kB
Energy Code Forms 20240322 050414.pdf 2024.03.22 1.02MB
Truss Engineering 20240322 045411.pdf 2024.03.22 548.16kB
Reviewed Architectural Plans 64539 2024-03-21 08.48.32.771.pdf 2024.03.21 6.96MB
Reviewed Manual J Forms 64539 2024-03-21 08.48.32.396.pdf 2024.03.21 419.93kB
179 Se Tristin Ln 2024-03-14 15.15.08.149.pdf 2024.03.14 871.57kB
Property Appraiser Parcel Details Printed Page 20240313 142533.pdf 2024.03.13 972.61kB
Product Approval Code Specifications Form 20240313 142533.pdf 2024.03.13 850.34kB
Site Plan 20240313 133249.pdf 2024.03.13 173.09kB
Owner And Contractor Signature Page 20240313 132552.pdf 2024.03.13 823.17kB
Recorded Deed 20240312 162959.pdf 2024.03.12 936.36kB