Columbia County is committed to ensuring accessibility to this website regardless of disability. If anyone encounters a feature on this website that is inaccessible due to a disability, please contact the County Manger’s Office and the Columbia County Board of County Commissioners at (386) 758-1005. You may also email that office at patrick_weaver@columbiacountyfla.com and provide a brief description of the inaccessible feature. The County will either correct the inaccessible feature or, if correction is not possible due to technical limitations, provide the desired information through alternative means.

Skip to content

Columbia County, FL | Permit Details

Additions Permit
Address 1402 SW TOMMY LITES ST
FORT WHITE, FL 32038
Parcel #: 09687-001
Acres: 9.83
Owner: Harrell Lee H, Harrell Denise A
Subdivision:
Zoning: A-3
Flood Zone: X
District: 4
Application #: 64616
Permit #: 000049785
Related Permit:
Submitted: Wednesday, March 20, 2024
Issued: Monday, May 13, 2024
Expires: Friday, November 15, 2024
Completed: Friday, November 15, 2024
Status: Completed
Septic Release? Yes
Notes:
ZONING: ADDITION WITHIN EXISTING FOOTPRINT
Job Details
Is this an addition for commercial or residential use? Residential
Description of addition: ENCLOSE CARPORT
Total Estimated Cost 170614.11
Heated Area (Sqft) 714
Total Area (Sqft) 714
Stories 1
Select driveway access to property: Existing Drive
Fire sprinklers? No
Building Code Construction Type V
Building Code Occupancy Types Residential
Building Code Element B
Occupancy Use Title carport
Setbacks Front 30'
Setback Side 1 25'
Setback Side 2 25'
Setback Rear 25'
Septic# (00-0000) or (X00-000) 24-0288
Dev Permit # F023-
Building Code Edition 2023 Florida Building Code 8th Edition and 2020 National Electrical Code
Elevation regulation Minimum Requirement
Finished floor requirement Meet existing structure
Fema map number 12023C0505C
Sealed roof decking options. (Must select one.) two layers of felt underlayment comply ASTM 0226 Type II or ASTM D4869 Type Ill or IV, or two layers of a synthetic underlayment meeting the performance requirements specified, lapped and fastened as specified.
Review Notes
3/20/2024 Application pending.
3/20/2024 Application submitted by applicant.
3/24/2024 Point Review - Printed-Online Application NEEDED: *POWER COMPANY SELECTED *RESIDENTIAL CHECKLIST *PRODUCT APPROVAL CODES LIST *ENV HEALTH-- CONTACT 386-758-1058 *TRUSS ENGINEEROMG (?)-- TO BE DETERMINED UPON PLAN REVIEW
3/24/2024 Point Review - Reviewed NEEDED: *POWER COMPANY SELECTED *RESIDENTIAL CHECKLIST *PRODUCT APPROVAL CODES LIST *ENV HEALTH-- CONTACT 386-758-1058 *TRUSS ENGINEEROMG (?)-- TO BE DETERMINED UPON PLAN REVIEW
4/1/2024 Plan Review - Documents Required NEEDED: *POWER COMPANY SELECTED *PRODUCT APPROVAL CODES LIST *ENV HEALTH-- CONTACT 386-758-1058 *TRUSS ENGINEEROMG (?)-- TO BE DETERMINED UPON PLAN REVIEW
4/9/2024 Plan Review - Contact the Building Dept NEEDED: *ENV HEALTH-- CONTACT 386-758-1058 *TRUSS ENGINEEROMG (?)-- TO BE DETERMINED UPON PLAN REVIEW
4/15/2024 Plan Review - Documents Required NEEDED: **SEALED TRUSS ENGINEERING *ENV HEALTH-- CONTACT 386-758-1058 *TRUSS ENGINEERING (?)-- TO BE DETERMINED UPON PLAN REVIEW
4/23/2024 Zoning Review - Reviewed NEEDED: *ENV HEALTH-- CONTACT 386-758-1058-- UPDATED ONE NEEDED ZONING: EXISTING FOOTPRINT.
5/10/2024 Plan Review - Reviewed
5/13/2024 Final Review - Reviewed
5/13/2024 Final Review - Payment Needed
5/13/2024 Permit Issued Permit #000049785 created and approved.
Contractors
Name/ Business License Title Role
Leslie R Mcdaniel
Reed Mcdaniel Construction Inc
CBC1255787 Cert. Building Contractor
Cody Barrs
Barrs Plumbing Inc
CFC1427145 Plumbing Contractor Subcontractor
Donald Davis
High Springs Electric Inc
EC0002306 Electrical Contractor Subcontractor
Richard M Touchstone
Touchstone Heating & Air Inc
CAC058099 Class B A/c Contractor Subcontractor
Inspections
Inspection Notes Performed By Date
Septic Release Inspection Health Dept 5/8/2024
Failed: Plumbing/Gas - 1st Underground Rough–In Dwv Piping Running In Footings Anthony Aslan 6/11/2024
Passed: Plumbing/Gas - 1st Underground Rough–In Rec'vd Photos Anthony Aslan 6/14/2024
Passed: Building - Slab Gary Pitzer 6/17/2024
Passed: Building - Wall Sheathing Anthony Aslan 6/26/2024
Passed: Building - Framing Anthony Aslan 6/28/2024
Failed: Mechanical - Rough In Exhaust Fans Not Vented Anthony Aslan 7/17/2024
Passed: Plumbing/Gas - 2nd Rough-In Anthony Aslan 7/17/2024
Cancelled: Electrical - 1st Underground Rough–In Anthony Aslan 7/17/2024
Passed: Electrical - 2nd Rough-In Anthony Aslan 7/17/2024
Passed: Mechanical - Rough In Anthony Aslan 7/19/2024
Failed: Building - Insulation No Baffling Installed To Allow Heat Transfer Anthony Aslan 8/20/2024
Passed: Building - Insulation Corrections Made Anthony Aslan 8/21/2024
Failed: Building - Final Need Disconnect For Ahu, Locking Caps For Service Valves no Toilet, Faucets Installed other Multiple Items Missing Anthony Aslan 10/23/2024
Rescheduled 11/13/2024:Building - Final Anthony Aslan 11/12/2024
Passed: Building - Final Need Picture Of Chase Around A/c Line Set And Locking Caps Anthony Aslan 11/13/2024
Certificate-Release Certificate Received Anthony Aslan 11/15/2024
Documents
File Name Date File Size
Certificate Of Occupancy 20241115.pdf 2024.11.15 62.21kB
Under Ground Plumbing Moved 2024-06-18 12.09.16.597.heic 2024.06.18 529.50kB
Plumbing Under Ground 2024-06-14 13.17.07.673 2024.06.14 529.50kB
Original Permit 20240513.pdf 2024.05.13 46.52kB
64616 Setbacks Or- 2024-05-09 09.00.17.505.pdf 2024.05.09 144.00kB
Harrell Eh 2024-05-08 09.37.20.593.pdf 2024.05.08 808.13kB
Architectural Plans 20240503 101127.pdf 2024.05.03 1.52MB
Structural Engineering And Wind Load Calculations 20240503 101101.pdf 2024.05.03 2.59MB
Septic Approval Paperwork 20240503 100821.pdf 2024.05.03 1.65MB
Reviewed Truss Engineering 64616 2024-04-22 08.55.23.547.pdf 2024.04.22 484.25kB
Truss Engineering 20240415 132930.pdf 2024.04.15 265.86kB
Truss Engineering 20240415 132643.pdf 2024.04.15 433.79kB
Site Plan 20240403 095408.pdf 2024.04.03 187.46kB
Reviewed Engineering 64616.pdf 2024.04.01 2.63MB
Reviewed Plan Set 64616 (1) 2024-04-01 09.53.17.809.pdf 2024.04.01 1.55MB
Residential Or Commercial Checklist 20240325 092308.pdf 2024.03.25 563.18kB
Product Approval Code Specifications Form 20240325 082106.pdf 2024.03.25 96.81kB
Manual J Forms 20240321 092216.pdf 2024.03.21 338.06kB
Subcontractor Form 20240320 093614.pdf 2024.03.20 51.68kB
Structural Engineering And Wind Load Calculations 20240320 093613.pdf 2024.03.20 2.59MB
Recorded Notice Of Commencement 20240320 093613.pdf 2024.03.20 68.59kB
Contractor Letter Of Authorization 20240320 093613.pdf 2024.03.20 76.91kB
Site Plan 20240320 093429.pdf 2024.03.20 40.69kB
Property Appraiser Parcel Details Printed Page 20240320 093429.pdf 2024.03.20 136.53kB
Owner And Contractor Signature Page 20240320 093429.pdf 2024.03.20 605.63kB