Columbia County is committed to ensuring accessibility to this website regardless of disability. If anyone encounters a feature on this website that is inaccessible due to a disability, please contact the County Manger’s Office and the Columbia County Board of County Commissioners at (386) 758-1005. You may also email that office at patrick_weaver@columbiacountyfla.com and provide a brief description of the inaccessible feature. The County will either correct the inaccessible feature or, if correction is not possible due to technical limitations, provide the desired information through alternative means.

Skip to content

Columbia County, FL | Permit Details

Roof Replacement or Repair Permit

Address 106 SW VERA GLN
LAKE CITY, FL 32024
Parcel #: 09137-006
Acres: 1.12
Owner: Dinges Sara
Subdivision: Tinas Unr Unit 2
Zoning: A-3
Flood Zone: AE
District: 5
Application #: 65213
Permit #: 000049746
Related Permit:
Submitted: Tuesday, May 7, 2024
Issued: Wednesday, May 8, 2024
Expires: Wednesday, June 5, 2024
Completed: Wednesday, June 5, 2024
Status: Completed
Septic Release? na
Notes:
PICS AND AFFIDAVIT REC'D
Job Details
Finished floor requirement
Fema map number 12023C0384D
Type Roofing Job Replacement - Tear off Existing and Replace
Further Job Details (Explain if decking is being replaced and or Repairs are being done.) tear off existing to deck and cover with new shingles
Type of structure House
Commercial or Residential Residential
Roof Area (for this job) Sq Ft 2001
No. of Stories 1
Roof Pitch 2:12 to 4:12
Is the existing roof being removed? Yes
Type of New Roofing Product Asphalt Shingles
Florida Product Approval Number FL18355
Product Manufacturer Tamko
Product Description titan xt
Building Code Edition 2023 Florida Building Code 8th Edition and 2020 National Electrical Code
Sealed roof decking options: (Must select an option.) two layers of felt underlayment comply ASTM 0226 Type II or ASTM D4869 Type Ill or IV, or two layers of a synthetic underlayment meeting the performance requirements specified, lapped and fastened as specified.
Ventilation: Off-ridge Vent
Flashing: Replace All
Drip Edge: Replace All
Valley Treatment: New Metal
Review Notes
5/7/2024 Application pending.
5/7/2024 Application submitted by applicant.
5/7/2024 Final Review - Corrections Needed NEED * APPLICANT ADDRESS NEEDS CITY, STATE, ZIP
5/7/2024 Final Review - Payment Needed NEED
5/8/2024 Permit Issued Permit # created and approved from payment.
6/4/2024 Final Review - Reviewed PLEASE BE CAREFUL WHEN USING TIMESTAMP APPS - ADDRESS ON PICTURES DO NOT ALL MATCH THE JOB ADDRESS
Contractors
Name/ Business License Title Role
Marc Boutilier
Florida Premier Roofing Llc
CCC1333919 Cert. Roofing Contractor
Inspections
Inspection Notes Performed By Date
Passed: Re-Roof - In Progress In Progress Gary Pitzer 5/29/2024
Passed: Re-Roof - Final Troy Crews 6/5/2024