Finished floor requirement |
|
Fema map number |
12023C0405C |
Type Roofing Job |
Overlay with Metal |
Further Job Details (Explain if decking is being replaced and or Repairs are being done.) |
This is a labor only job for TMT Roofing. Ronnie Rollins has provided his own materials. All of his materials were purchased from Tri County Metals |
Type of structure |
Mobile Home |
Commercial or Residential |
Residential |
Roof Area (for this job) Sq Ft |
16 |
No. of Stories |
1 |
Roof Pitch |
2:12 to 4:12 |
Is the existing roof being removed? |
No |
Explain if not removing the existing roofing material? |
Metal over existing shingle |
Type of New Roofing Product |
Metal |
Florida Product Approval Number |
# 36904.2 |
Product Manufacturer |
Tri County Metals |
Product Description |
Min. 29 Ga. |
Building Code Edition |
2023 Florida Building Code 8th Edition and 2020 National Electrical Code |
Sealed roof decking options: (Must select an option.) |
a minimum 4-inch wide strip of selfadhering polymer-modified bitumen complying with ASTM D1970 or a minimum 3 ¾ - inch wide strip of selfadhering flexible flashing tape complying with AAMA 711, applied over all joints in the roof decking. A felt underlayment complying with ASTM D226 Type II, ASTM D4869 Type Ill or IV, or ASTM D6757, or a synthetic underlayment meeting the performance requirements specified, is required to be applied over the strips/tape over the entire roof. |
Ventilation: |
Ridge Vent |
Flashing: |
Use Existing |
Drip Edge: |
Replace All |
Valley Treatment: |
New Metal |
Any cable and/or race-way wiring located on or within the roof assembly? |
No |