Columbia County is committed to ensuring accessibility to this website regardless of disability. If anyone encounters a feature on this website that is inaccessible due to a disability, please contact the County Manger’s Office and the Columbia County Board of County Commissioners at (386) 758-1005. You may also email that office at patrick_weaver@columbiacountyfla.com and provide a brief description of the inaccessible feature. The County will either correct the inaccessible feature or, if correction is not possible due to technical limitations, provide the desired information through alternative means.

Skip to content

Columbia County, FL | Permit Details

Roof Replacement or Repair Permit

Address 1151 NW SCENIC LAKE DR
LAKE CITY, FL 32055
Parcel #: 02268-344
Acres: 1.67
Owner: Peacock Walter R Jr, Peacock Jon Michael
Subdivision:
Zoning: RSF-2
Flood Zone: X
District: 3
Application #: 64605
Permit #: 000049474
Related Permit:
Submitted: Wednesday, March 20, 2024
Issued: Thursday, March 21, 2024
Expires: Wednesday, April 3, 2024
Completed: Wednesday, April 3, 2024
Status: Completed
Septic Release? na
Notes:

Job Details
Finished floor requirement
Fema map number 12023C0280D
Type Roofing Job Replacement - Tear off Existing and Replace
Further Job Details (Explain if decking is being replaced and or Repairs are being done.) Replace wood as needed
Type of structure House
Commercial or Residential Residential
Roof Area (for this job) Sq Ft 47
No. of Stories 1
Roof Pitch 4:12 or Greater
Is the existing roof being removed? Yes
Type of New Roofing Product Asphalt Shingles
Florida Product Approval Number FL18355-R8
Product Manufacturer TAMKO
Product Description HERITAGE
Building Code Edition 2023 Florida Building Code 8th Edition and 2020 National Electrical Code
Sealed roof decking options: (Must select an option.) two layers of felt underlayment comply ASTM 0226 Type II or ASTM D4869 Type Ill or IV, or two layers of a synthetic underlayment meeting the performance requirements specified, lapped and fastened as specified.
Ventilation: Ridge Vent
Flashing: Replace All
Drip Edge: Replace All
Valley Treatment: New Mineral Surface
Any cable and/or race-way wiring located on or within the roof assembly? No
Review Notes
3/19/2024 Application pending.
3/20/2024 Application submitted by applicant.
3/20/2024 Final Review - Payment Needed
3/21/2024 Permit Issued Permit #000049474 created and approved.
Contractors
Name/ Business License Title Role
Lewis G Walker
Lewis Walker Roofing Inc
CCC1333551 Cert. Roofing Contractor
Inspections
Inspection Notes Performed By Date
Cancelled: Re-Roof - In Progress Emaleigh Williams 3/25/2024
Passed: Re-Roof - In Progress In Progress With Tear Off Gary Pitzer 3/26/2024
Passed: Engineering - Access Road/Driveway Right-of-Way Integrity Inspection Gary Pitzer 4/3/2024
Passed: Re-Roof - Final Gary Pitzer 4/3/2024