Columbia County is committed to ensuring accessibility to this website regardless of disability. If anyone encounters a feature on this website that is inaccessible due to a disability, please contact the County Manger’s Office and the Columbia County Board of County Commissioners at (386) 758-1005. You may also email that office at patrick_weaver@columbiacountyfla.com and provide a brief description of the inaccessible feature. The County will either correct the inaccessible feature or, if correction is not possible due to technical limitations, provide the desired information through alternative means.

Skip to content

Columbia County, FL | Permit Details

Remodel Permit
Address 1580 E DUVAL ST
LAKE CITY, FL 32055
Parcel #: 06430-002
Acres: 0.24
Owner: Barak N, Llc,
Subdivision: Morningside Heights
Zoning: CI
Flood Zone: X
District: 1
Application #: 64147
Permit #: 000049473
Related Permit:
Submitted: Wednesday, February 7, 2024
Issued: Thursday, March 21, 2024
Expires: Wednesday, January 15, 2025
Completed: Wednesday, January 15, 2025
Status: Completed
Septic Release? No
Notes:
INTERIOR REMODEL ONLY NO SITE WORK OR ADDITIONS, PROPERTY IS LEGAL NON-CONFORMING USE
Job Details
Description of the work being performed: remodel of hotel
Commercial or Residential? Commercial
Type of Structure Business
Building Code Construction Type V
Building Code Element B
Building Code Occupancy Types Residential
Occupancy Use Title motel / apartments
Septic# 24-0689
Dev Permit # F023-
Building Code Edition 2023 Florida Building Code 8th Edition and 2020 National Electrical Code
Fema map number 12023C0305D
Review Notes
2/7/2024 City of Lake City Utilities Notified. City of Lake City Notified of Application within Utility Service Areas LC_GAS, LC_WATER,.
2/19/2024 Point Review - Documents Required AWAITING FIRE WALL PLAN REVISION
2/28/2024 Point Review - Documents Required AWAITING FIRE WALL PLAN REVISION
3/8/2024 Point Review - Documents Required AWAITING FIRE WALL PLAN REVISION
3/15/2024 Point Review - Documents Required AWAITING FIRE WALL PLAN REVISION
3/18/2024 Point Review - Documents Required AWAITING FIRE WALL PLAN REVISION
3/20/2024 Plan Review - Documents Required AWAITING FIRE WALL PLAN REVISION-- DOCUEMENTS REC'D, PENDING REVIEW
3/21/2024 Point Review - Reviewed
3/21/2024 Plan Review - Plumbing Approved
3/21/2024 Plan Review - Mechanical Approved
3/21/2024 Plan Review - Electrical Approved
3/21/2024 Plan Review - Building Approved
3/21/2024 Plan Review - Reviewed
3/21/2024 Zoning Review - Reviewed
3/21/2024 Final Review - Processing
3/21/2024 Final Review - Payment Needed
3/21/2024 Permit Issued Permit # created and approved from payment.
Contractors

This is an owner builder project.

Name/ Business License Title Role
Inspections
Inspection Notes Performed By Date
Passed: Fire - Fire Rated Wall Framing Done In Order To Take Two Layes Each Side Up To Bottom Of Roof Deck Troy Crews 5/14/2024
Passed: Building - Fire Rated Wall Troy Crews 5/23/2024
Failed: Electrical - 2nd Rough-In Need To Sleeve Service Wires To Panel With Metal Piping Extending 18 Inches Each Side Of Fire Wall And Sealed With Fire Foam Troy Crews 5/23/2024
Passed: Fire - Fire Rated Wall Cpt. Shane Ovesterrt 5/28/2024
Passed: Electrical - 2nd Rough-In Metal Sleeves Installed On Wiring Thru Fire Wall Troy Crews 6/3/2024
Passed: Plumbing/Gas - 1st Underground Rough–In Waste Only Troy Crews 6/21/2024
Rescheduled 6/25/2024:Plumbing/Gas - 2nd Rough-In Troy Crews 6/24/2024
Failed: Plumbing/Gas - 2nd Rough-In Building Locked Need Water Line Pressure Test Inspection Troy Crews 6/25/2024
Passed: Plumbing/Gas - 2nd Rough-In All Tubs Were Water Tested(5) Water Pressure Was Up On All Units(5) Matt Forsyth 7/17/2024
Passed: Building - Fire Rated Wall All Lines Fire Foam Sealed Troy Crews 8/8/2024
Passed: Electrical - Permanent Power Need Septic Final Troy Crews 1/7/2025
Release to power company Troy Crews 1/9/2025
Release to power company Melissa Garber 1/9/2025
Passed: Building - Final Checked All Ground Fault Receptacle Smoke Detectors Etc. Troy Crews 1/15/2025