Columbia County is committed to ensuring accessibility to this website regardless of disability. If anyone encounters a feature on this website that is inaccessible due to a disability, please contact the County Manger’s Office and the Columbia County Board of County Commissioners at (386) 758-1005. You may also email that office at patrick_weaver@columbiacountyfla.com and provide a brief description of the inaccessible feature. The County will either correct the inaccessible feature or, if correction is not possible due to technical limitations, provide the desired information through alternative means.

Skip to content

Columbia County, FL | Permit Details

Roof Replacement or Repair Permit
Address 209 SW MORNING GLORY DR
LAKE CITY, FL 32024
Parcel #: 03023-505
Acres: 0.51
Owner: Urrely Jarrod Joseph, Urrely Tarsis Zoraida
Subdivision: Rolling Meadows
Zoning: RSF-2
Flood Zone: X
District: 3
Application #: 63911
Permit #: 000049365
Related Permit:
Submitted: Thursday, January 18, 2024
Issued: Wednesday, March 6, 2024
Expires: Thursday, March 7, 2024
Completed: Thursday, March 7, 2024
Status: Completed
Septic Release? na
Notes:

Job Details
Type Roofing Job Replacement - Tear off Existing and Replace
Further Job Details (Explain if decking is being replaced and or Repairs are being done.) 50 sq Re Roof 10/12 Pitch Shingles FL10674
Type of structure House
Commercial or Residential Residential
Roof Area (for this job) Sq Ft 50
No. of Stories 1
Ventilation: Ridge Vent
Flashing: Replace with Step Flashing
Drip Edge: Replace All
Valley Treatment: New Mineral Surface
Roof Pitch 4:12 or Greater
Any cable and/or race-way wiring located on or within the roof assembly? No
Is the existing roof being removed? Yes
Type of New Roofing Product Asphalt Shingles
Florida Product Approval Number FL10674
Product Manufacturer Owens Corning
Product Description Shingles
Sealed roof decking options: (Must select an option.) a minimum 4-inch wide strip of selfadhering polymer-modified bitumen complying with ASTM D1970 or a minimum 3 ¾ - inch wide strip of selfadhering flexible flashing tape complying with AAMA 711, applied over all joints in the roof decking. A felt underlayment complying with ASTM D226 Type II, ASTM D4869 Type Ill or IV, or ASTM D6757, or a synthetic underlayment meeting the performance requirements specified, is required to be applied over the strips/tape over the entire roof.;two layers of felt underlayment comply ASTM 0226 Type II or ASTM D4869 Type Ill or IV, or two layers of a synthetic underlayment meeting the performance requirements specified, lapped and fastened as specified.
Building Code Edition 2023 Florida Building Code 8th Edition and 2020 National Electrical Code
Fema map number 12023C0289D
Review Notes
1/18/2024 Application pending.
1/18/2024 Application submitted by applicant.
1/18/2024 City of Lake City Utilities Notified. City of Lake City Notified of Application within Utility Service Areas LC_WATER,.
1/18/2024 Final Review - Corrections Needed NEED *CECIL DAVID WILLIAMS NEED TO REGISTER WITH US *ALL DOCUMENTS HAVE BEEN UPDATED YOU WILL NEED TO SEND US THE UPDATED SIGNED OWNER/CONTRACTOR FORM FOR THIS APPLICATION. ALSO PLEASE BE ADVISED THAT ALL DOCUMENTS WILL NEED TO BE THE UPDATE FORMS NEXT TIME.
1/29/2024 Final Review - Corrections Needed NEED *CECIL DAVID WILLIAMS NEED TO REGISTER WITH US *ALL DOCUMENTS HAVE BEEN UPDATED YOU WILL NEED TO SEND US THE UPDATED SIGNED OWNER/CONTRACTOR FORM FOR THIS APPLICATION. ALSO PLEASE BE ADVISED THAT ALL DOCUMENTS WILL NEED TO BE THE UPDATED FORMS NEXT TIME.
2/2/2024 Final Review - Corrections Needed NEED *CECIL DAVID WILLIAMS NEED TO REGISTER WITH US *ALL DOCUMENTS HAVE BEEN UPDATED YOU WILL NEED TO SEND US THE UPDATED SIGNED OWNER/CONTRACTOR FORM FOR THIS APPLICATION. ALSO PLEASE BE ADVISED THAT ALL DOCUMENTS WILL NEED TO BE THE UPDATED FORMS NEXT TIME.
3/1/2024 Final Review - Corrections Needed NEED *CECIL DAVID WILLIAMS NEED TO REGISTER WITH US *ALL DOCUMENTS HAVE BEEN UPDATED YOU WILL NEED TO SEND US THE UPDATED SIGNED OWNER/CONTRACTOR FORM FOR THIS APPLICATION. ALSO PLEASE BE ADVISED THAT ALL DOCUMENTS WILL NEED TO BE THE UPDATED FORMS NEXT TIME.
3/5/2024 Point Review - Reviewed NEED *CECIL DAVID WILLIAMS NEED TO REGISTER WITH US *ALL DOCUMENTS HAVE BEEN UPDATED YOU WILL NEED TO SEND US THE UPDATED SIGNED OWNER/CONTRACTOR FORM FOR THIS APPLICATION. ALSO PLEASE BE ADVISED THAT ALL DOCUMENTS WILL NEED TO BE THE UPDATED FORMS NEXT TIME.
3/5/2024 Plan Review - Reviewed NEED *CECIL DAVID WILLIAMS NEED TO REGISTER WITH US *ALL DOCUMENTS HAVE BEEN UPDATED YOU WILL NEED TO SEND US THE UPDATED SIGNED OWNER/CONTRACTOR FORM FOR THIS APPLICATION. ALSO PLEASE BE ADVISED THAT ALL DOCUMENTS WILL NEED TO BE THE UPDATED FORMS NEXT TIME.
3/5/2024 Zoning Review - Reviewed NEED *CECIL DAVID WILLIAMS NEED TO REGISTER WITH US *ALL DOCUMENTS HAVE BEEN UPDATED YOU WILL NEED TO SEND US THE UPDATED SIGNED OWNER/CONTRACTOR FORM FOR THIS APPLICATION. ALSO PLEASE BE ADVISED THAT ALL DOCUMENTS WILL NEED TO BE THE UPDATED FORMS NEXT TIME.
3/5/2024 Final Review - Corrections Needed NEED *CECIL DAVID WILLIAMS NEED TO REGISTER WITH US *ALL DOCUMENTS HAVE BEEN UPDATED YOU WILL NEED TO SEND US THE UPDATED SIGNED OWNER/CONTRACTOR FORM FOR THIS APPLICATION. ALSO PLEASE BE ADVISED THAT ALL DOCUMENTS WILL NEED TO BE THE UPDATED FORMS NEXT TIME.
3/6/2024 Final Review - Corrections Needed NEED *CECIL DAVID WILLIAMS NEED TO REGISTER WITH US *ALL DOCUMENTS HAVE BEEN UPDATED YOU WILL NEED TO SEND US THE UPDATED SIGNED OWNER/CONTRACTOR FORM FOR THIS APPLICATION. DOCUMENTS ARE STILL WRONG. PLEASE GO TO OUR WEBSITE AND PULL THEM FROM THERE. THEY ARE ALL UPDATED ON OUR WEBSITE. ALSO PLEASE BE ADVISED THAT ALL DOCUMENTS WILL NEED TO BE THE UPDATED FORMS NEXT TIME.
3/6/2024 Final Review - Payment Needed
3/6/2024 Permit Issued Permit # created and approved from payment.
Contractors
Name/ Business License Title Role
Cecil D Williams
Quality Labor Souce
CCC1332875 Cert. Roofing Contractor
Inspections
Inspection Notes Performed By Date
Passed: Re-Roof - Final Pass Per Photos And Affidavit Only, Please For Your Next Permit, Be Advised We Require An Inprogress Inspection While Roof Project Is Being Done Gary Pitzer 3/7/2024