Permit Details

Permit Search

Permit

New Commercial Construction

2529 SW STATE ROAD 47
LAKE CITY, FL 32025

Permit #
000049328
Application #
64138
Status Completed
  1. Submitted Feb 7, 2024
  2. Issued Mar 1, 2024
  3. Expires Mar 9, 2025
  4. Completed Oct 15, 2024

Property

Parcel #
08479-005
Owner
Mini-storage & Record Storage Of Lake City Inc
Acres
7.71
Subdivision
—
Zoning
CI
Flood zone
X
District
5

Permit

Status
Completed
Septic release
Not yet released
Related permit
—

Job Details

Elevation regulation
Site & Development Plan
Finished floor requirement
97.3'
Requirement needed
By Nailing Inspection
Document needed is
a Surveyor letter giving the Finished Floor Elevation
Document receieved
Yes
Fema map number
12023C0294D
This is the construction of a:
mini warehouse/storage bldg 1100
Driveway access to property:
Existing Drive
Total Area (Sqft)
8900
Building Code Construction Type
III
Building Code Element
B
Building Code Occupancy Types
Storage
Occupancy Use Title
storage
Dev Permit #
F023-
Design Occupant Load
0
Building Code Edition
2023 Florida Building Code 8th Edition and 2020 National Electrical Code
Sealed roof decking options. (Must select one.)
Other (explain)
Sealed roof decking explanation for other option.
metal building

Status & Review History

  1. City of Lake City Utilities Notified.
  2. Point Review - Reviewed
  3. Plan Review - Documents Required
  4. Plan Review - Electrical Approved
  5. Plan Review - Building Approved
  6. Plan Review - Reviewed
  7. Zoning Review - Reviewed
  8. Final Review - Processing
  9. Final Review - Documents Required
  10. Final Review - Payment Needed
  11. Permit Issued

Contractors

  • Frank A Todd Iii(mike)

    Mike Todd Construction Inc

    License
    CGC006209
    Title
    General Contractor
    Role
    Contractor
  • Mike L Alban

    Alban Electric Llc

    License
    EC13001888
    Title
    Electrical Contractor
    Role
    Subcontractor

    County License & State License & Liability Insurance & Workers Comp Expired.

Inspections

  1. Feb 16, 2024

    Passed: Fire - Plan Review

    Inspected by Cpt .shane Overstreet

  2. Mar 4, 2024

    Passed: Building - Monolithic Slab

    Inspected by Troy Crews

  3. Mar 4, 2024

    Passed: Engineering - Setbacks

    Inspected by Troy Crews

  4. Jun 7, 2024

    Passed: Building - Insulation

    Fire Wall Ceiling Each Side At 2500 Sq. Ft.

    Inspected by Troy Crews

  5. Aug 1, 2024

    Passed: Fire - Fire Final

    Inspected by Cpt. Shane Overstreet

  6. Sep 10, 2024

    Certificate-Release Certificate

    Inspected by Troy Crews

  7. Sep 10, 2024

    Passed: Building - Final

    Cannot Closed Permit Or Release Certificate Of Occupancy Due To Missing Required Documents.

    Inspected by Troy Crews