Permit Details

Permit Search

Permit

New Commercial Construction

12087 SW US HIGHWAY 27
FORT WHITE, FL 32038

Permit #
000049313
Application #
63751
Status Completed
  1. Submitted Jan 2, 2024
  2. Issued Feb 29, 2024
  3. Expires Feb 15, 2025
  4. Completed Aug 19, 2024

Property

Parcel #
00515-000
Owner
Tiitf/dep-rec & Parks
Acres
130.97
Subdivision
—
Zoning
A-3
Flood zone
X
District
2

Permit

Status
Completed
Septic release
Released
Related permit
—

Job Details

Finished floor requirement
Fema map number
12023C0459C
This is the construction of a:
day use restroom facility
Driveway access to property:
Existing Drive
Is there a Fire Sprinkler System?
No
Setbacks Front
30'
Setback Side 1
25'
Setback Side 2
25'
Setback Rear
25'
Describe commercial use:
day use restroom for the South entrance the Ichetucknee Springs State Park
Stories
1
Heated Area (Sqft)
100
Total Area (Sqft)
1115
Building Height
18
Building Code Construction Type
II
Building Code Element
B
Occupancy Use Title
FBC Group B Business
Dev Permit #
F023-
Design Occupant Load
10 persons
Building Code Edition
2023 Florida Building Code 8th Edition and 2020 National Electrical Code
Septic# (00-0000) or (X00-000)
22-1019
Sealed roof decking options. (Must select one.)
a self-adhering polymer-modified bitumen underlayment complying with ASTM D1970 applied over the entire roof.
Service Amps
200

Status & Review History

  1. Application pending.
  2. Application submitted by applicant.
  3. Point Review - Printed-Online Application
  4. Plan Review - Plumbing Approved
  5. Plan Review - Mechanical Approved
  6. Plan Review - Electrical Approved
  7. Plan Review - Building Approved
  8. Plan Review - Reviewed
  9. Zoning Review - Reviewed
  10. Final Review - Documents Required
  11. Final Review - Documents Required
  12. Final Review - Documents Required
  13. Final Review - Documents Required
  14. Final Review - Processing
  15. Final Review - Payment Needed
  16. Permit Issued
  17. Permit Renewed

Contractors

  • Erik W Worthmann

    Comfort Temp Company Dba Ct Mechanical

    License
    CMC1249305
    Title
    Cert. Mechanical
    Role
    Subcontractor

    County License & State License Expired.

  • Matthew E Gera

    Preston-link Electric,inc.

    License
    EC13007791
    Title
    Electrical Contractor
    Role
    Subcontractor

    County License & State License Expired.

  • Chad J Opaleski

    Chad's Water Works Plumbing, Llc

    License
    CFC1427646
    Title
    Cert. Plumbing
    Role
    Subcontractor

    County License & State License & Liability Insurance & Workers Comp Expired.

  • Dana D Johnson

    Mac Johnson Roofing Inc Dba Gulf Coast Metal Roofing

    License
    CCC1325497
    Title
    Cert Roofing
    Role
    Subcontractor

    County License & State License & Liability Insurance Expired.

  • Derek Dykes

    Blackwater Construction Services Llc

    License
    CGC1533394
    Title
    Cert. General
    Role
    Contractor

    County License & State License Expired.

Inspections

  1. Mar 1, 2024

    Passed: Plumbing/Gas - 2nd Rough-In

    First Rough Slab

    Inspected by Troy Crews

  2. Mar 5, 2024

    Cancelled: Building - Slab

    Inspected by Neonta Anderson

  3. Mar 7, 2024

    Passed: Building - Slab

    Inspected by Anthony Aslan

  4. Mar 27, 2024

    Septic Release Inspection

    Inspected by Health Dept

  5. Apr 22, 2024

    Passed: Building - Vertical Cells/Columns

    Inspected by Anthony Aslan

  6. Apr 26, 2024

    Passed: Building - Lintel/Tie Beam

    Need Pictures Of Rebar Tied

    Inspected by Anthony Aslan

  7. May 6, 2024

    Passed: Building - Masonry Wall Reinforcing

    Outside Walls

    Inspected by Anthony Aslan

  8. May 6, 2024

    Passed: Building - Vertical Cells/Columns

    Outside Walls

    Inspected by Anthony Aslan

  9. May 9, 2024

    Passed: Building - Lintel/Tie Beam

    Top Complete

    Inspected by Anthony Aslan

  10. May 13, 2024

    Passed: Building - Roof Decking

    Inspected by Anthony Aslan

  11. May 13, 2024

    Passed: Building - Framing

    Inspected by Anthony Aslan

  12. May 22, 2024

    Passed: Electrical - Above Ceiling

    Inspected by Troy Crews

  13. May 28, 2024

    Passed: Plumbing/Gas - 2nd Rough-In

    Inspected by Matt Forsyth

  14. May 29, 2024

    Passed: Mechanical - Rough In

    Piping To Fans Need Strapping

    Inspected by Anthony Aslan

  15. Jun 10, 2024

    Passed: Building - Roof Decking

    Inspected by Troy Crews

  16. Jun 17, 2024

    Cancelled: Building - Insulation

    Inspected by Emaleigh Williams

  17. Jun 18, 2024

    Failed: Electrical - Permanent Power

    Job Site Locked Also Need Doors On Building For Permanent Power

    Inspected by Troy Crews

  18. Jun 18, 2024

    Failed: Building - Insulation

    Job Site Lock

    Inspected by Troy Crews

  19. Jun 21, 2024

    Passed: Building - Insulation

    Inspected by Troy Crews

  20. Jun 21, 2024

    Passed: Electrical - Permanent Power

    Contractor To Install Door On Electric Room And Electrician To Keep Circuits Off Until Complete.

    Inspected by Troy Crews

  21. Jun 21, 2024

    Release to power company

    Inspected by Troy Crews

  22. Jun 25, 2024

    Passed: Plumbing/Gas - Sanitary

    Connection Was For Under The Road Final Connection Next To Clean Out Not Completed

    Inspected by Matt Forsyth

  23. Jun 25, 2024

    Passed: Plumbing/Gas - Water Pipe

    Water Has Been Under The Road To Lift Station Final Connection To Hydrant Has Not Been Made

    Inspected by Matt Forsyth

  24. Jun 27, 2024

    Release to power company

    Resending Due To Pwr Company Not Receiving

    Inspected by Troy Crews

  25. Aug 1, 2024

    Failed: Electrical - Permanent Power

    Job Site Locked Up 4:01pm

    Inspected by Troy Crews

  26. Aug 2, 2024

    Cancelled: Electrical - Permanent Power

    Inspected by Emaleigh Williams

  27. Aug 6, 2024

    Rescheduled 8/7/2024:Electrical - Permanent Power

    Inspected by Troy Crews

  28. Aug 7, 2024

    Passed: Electrical - Permanent Power

    Above Ceiling Also

    Inspected by Troy Crews

  29. Aug 7, 2024

    Release to power company

    Inspected by Troy Crews

  30. Aug 7, 2024

    Passed: Electrical - Above Ceiling

    Inspected by Troy Crews

  31. Aug 19, 2024

    Passed: Building - Final

    Inspected by Troy Crews