Permit Details

Permit Search

Permit

Roof Replacement or Repair

309 SW ATLANTIS PL
FORT WHITE, FL 32038

Permit #
000049298
Application #
64340
Status Completed
  1. Submitted Feb 26, 2024
  2. Issued Feb 27, 2024
  3. Expires Sep 15, 2024
  4. Completed Mar 19, 2024

Property

Parcel #
09827-005
Owner
Caswell James Burton
Acres
5.05
Subdivision
Mcclinton Farm
Zoning
A-3
Flood zone
X
District
4

Permit

Status
Completed
Septic release
N/A
Related permit
—

Job Details

Finished floor requirement
Fema map number
12023C0495C
Type Roofing Job
Replacement - Tear off Existing and Replace
Further Job Details (Explain if decking is being replaced and or Repairs are being done.)
Remove existing shingles and replace with new shingles on single family residence and add 3 sq. of modified bitumen on back flat section of roof.
Type of structure
House
Commercial or Residential
Residential
Roof Area (for this job) Sq Ft
2480
No. of Stories
1
Roof Pitch
2:12 to 4:12
Is the existing roof being removed?
Yes
Type of New Roofing Product
Asphalt Shingles
Florida Product Approval Number
FL#10674.1
Product Manufacturer
Owens Corning
Product Description
3-tab, 4-tab, laminated, starter and hip & ridge shingles for use in FBC non-HVHZ jurisdictions.
Building Code Edition
2023 Florida Building Code 8th Edition and 2020 National Electrical Code
Sealed roof decking options: (Must select an option.)
a minimum 4-inch wide strip of selfadhering polymer-modified bitumen complying with ASTM D1970 or a minimum 3 ¾ - inch wide strip of selfadhering flexible flashing tape complying with AAMA 711, applied over all joints in the roof decking. A felt underlayment complying with ASTM D226 Type II, ASTM D4869 Type Ill or IV, or ASTM D6757, or a synthetic underlayment meeting the performance requirements specified, is required to be applied over the strips/tape over the entire roof.;two layers of felt underlayment comply ASTM 0226 Type II or ASTM D4869 Type Ill or IV, or two layers of a synthetic underlayment meeting the performance requirements specified, lapped and fastened as specified.
Ventilation:
Ridge Vent
Flashing:
Replace All
Drip Edge:
Replace All
Valley Treatment:
Use Existing
Any cable and/or race-way wiring located on or within the roof assembly?
No

Status & Review History

  1. Application pending.
  2. Application submitted by applicant.
  3. Final Review - Payment Needed
  4. Permit Issued

Contractors

  • Donald Burnsed

    True Force Roofing

    License
    CCC1333814
    Title
    Cert. Roofing
    Role
    Contractor

    County License & State License Expired.

Inspections

  1. Mar 6, 2024

    Passed: Re-Roof - In Progress

    Inspected by Anthony Aslan

  2. Mar 19, 2024

    Passed: Re-Roof - Final

    Inspected by Anthony Aslan