Roof Replacement or Repair

185 NW FRIENDSHIP WAY
LAKE CITY, FL 32055

Permit #
000049281
Application #
64317
Status Completed
  1. Submitted Feb 23, 2024
  2. Issued Feb 23, 2024
  3. Expires Sep 8, 2024
  4. Completed Mar 12, 2024

Property

Parcel #
01772-015
Owner
Santiago Keila Luciano, Agosto Rodriguez Ruben A
Acres
4.05
Subdivision
Pinehills
Zoning
A-3
Flood zone
X
District
1

Permit

Status
Completed
Septic release
N/A
Related permit
—

Job Details

Finished floor requirement
Fema map number
12023C0190D
Type Roofing Job
Replacement - Tear off Existing and Replace
Further Job Details (Explain if decking is being replaced and or Repairs are being done.)
Remove existing roof and replace with new 26G metal on 1x4 purlins on mobile home.
Type of structure
Mobile Home
Commercial or Residential
Residential
Roof Area (for this job) Sq Ft
2040
No. of Stories
1
Roof Pitch
2:12 to 4:12
Is the existing roof being removed?
Yes
Type of New Roofing Product
Metal
Florida Product Approval Number
FL# 17992.1
Product Manufacturer
Capital Metal Supply, Inc.
Product Description
Min. 29 Ga. Capital Rib Roof Panel over 1x4 Wood Purlins over 7/16" OSB
Building Code Edition
2023 Florida Building Code 8th Edition and 2020 National Electrical Code
Sealed roof decking options: (Must select an option.)
two layers of felt underlayment comply ASTM 0226 Type II or ASTM D4869 Type Ill or IV, or two layers of a synthetic underlayment meeting the performance requirements specified, lapped and fastened as specified.
Ventilation:
Ridge Vent
Flashing:
Use Existing
Drip Edge:
Replace All
Valley Treatment:
Use Existing
Any cable and/or race-way wiring located on or within the roof assembly?
No

Status & Review History

  1. Application pending.
  2. Application submitted by applicant.
  3. Final Review - Payment Needed
  4. Permit Issued

Contractors

  • Donald Burnsed

    True Force Roofing

    License
    CCC1333814
    Title
    Cert. Roofing
    Role
    Contractor

    County License & State License Expired.

Inspections

  1. Mar 5, 2024

    Passed: Re-Roof - In Progress

    Inspected by Gary Pitzer

  2. Mar 12, 2024

    Passed: Re-Roof - Final

    Metal Roof

    Inspected by Gary Pitzer