Columbia County is committed to ensuring accessibility to this website regardless of disability. If anyone encounters a feature on this website that is inaccessible due to a disability, please contact the County Manger’s Office and the Columbia County Board of County Commissioners at (386) 758-1005. You may also email that office at patrick_weaver@columbiacountyfla.com and provide a brief description of the inaccessible feature. The County will either correct the inaccessible feature or, if correction is not possible due to technical limitations, provide the desired information through alternative means.

Skip to content

Columbia County, FL | Permit Details

Roof Replacement or Repair Permit

Address 133 SW STONEHENGE LN
LAKE CITY, FL 32024
Parcel #: 03099-118
Acres: 0.61
Owner: Garner Charles, Garner Holly Anne
Subdivision: Stonehenge Phase 1
Zoning: RSF-2
Flood Zone: X
District: 3
Application #: 64288
Permit #: 000049258
Related Permit:
Submitted: Wednesday, February 21, 2024
Issued: Wednesday, February 21, 2024
Expires: Wednesday, March 13, 2024
Completed: Wednesday, March 13, 2024
Status: Completed
Septic Release? na
Notes:

LAKE CITY UTLITY CUSTOMER SERVICE NOTES The City of Lake City does not provide utilities to this location.
Job Details
Finished floor requirement
Fema map number 12023C0293D
Type Roofing Job Replacement - Tear off Existing and Replace
Further Job Details (Explain if decking is being replaced and or Repairs are being done.) RE ROOF 41 SQ SHINGLES SFR
Type of structure House
Commercial or Residential Residential
Roof Area (for this job) Sq Ft 2854
No. of Stories 1
Roof Pitch 4:12 or Greater
Is the existing roof being removed? Yes
Type of New Roofing Product Asphalt Shingles
Florida Product Approval Number FL5444.1
Other Roofing Product Type Not Listed FL21841.1 FL2847.2
Product Manufacturer CERTAINTEED
Product Description LANDMARK
Building Code Edition 2023 Florida Building Code 8th Edition and 2020 National Electrical Code
Sealed roof decking options: (Must select an option.) two layers of felt underlayment comply ASTM 0226 Type II or ASTM D4869 Type Ill or IV, or two layers of a synthetic underlayment meeting the performance requirements specified, lapped and fastened as specified.
Ventilation: Ridge Vent
Flashing: Use Existing
Drip Edge: Replace All
Valley Treatment: New Mineral Surface
Any cable and/or race-way wiring located on or within the roof assembly? No
Review Notes
2/21/2024 Application pending.
2/21/2024 Application submitted by applicant.
2/21/2024 City of Lake City Utilities Notified. City of Lake City Notified of Application within Utility Service Areas LC_WATER,.
2/21/2024 Final Review - Payment Needed
2/21/2024 Permit Issued Permit # created and approved from payment.
Contractors
Name/ Business License Title Role
Richard Dorman
Roofing Pros Usa Llc Ii
CCC1333006 Cert. Roofing Contractor
Inspections
Inspection Notes Performed By Date
Passed: Re-Roof - In Progress Gary Pitzer 3/6/2024
Passed: Re-Roof - Final Gary Pitzer 3/13/2024