Columbia County is committed to ensuring accessibility to this website regardless of disability. If anyone encounters a feature on this website that is inaccessible due to a disability, please contact the County Manger’s Office and the Columbia County Board of County Commissioners at (386) 758-1005. You may also email that office at patrick_weaver@columbiacountyfla.com and provide a brief description of the inaccessible feature. The County will either correct the inaccessible feature or, if correction is not possible due to technical limitations, provide the desired information through alternative means.

Skip to content

Columbia County, FL | Permit Details

New Residential Construction Permit

Address 176 SW KIMBERLY LN
LAKE CITY, FL 32024
Parcel #: 03026-103
Acres: 1.00
Owner: Lev Joann T, Fochi William A
Subdivision: Kimberly Oaks
Zoning: RR
Flood Zone: X
District: 3
Application #: 63790
Permit #: 000049256
Related Permit: Culvert: 000049248
Submitted: Thursday, January 4, 2024
Issued: Wednesday, February 21, 2024
Expires: Friday, March 7, 2025
Completed: Friday, March 7, 2025
Status: Completed
Septic Release? Yes
Notes:
ELEVATION CONFIRMATION REC'D @ 97.28'
Job Details
Elevation regulation Subdivision Plat
Finished floor requirement 94.50'
Document needed is a Surveyor letter giving the Finished Floor Elevation
Document receieved Yes
Fema map number 12023C0289D
This is the construction of a Single Family Dwelling
Setbacks Front 25'
Setback Side 1 10'
Setback Side 2 10'
Setbacks Rear 15'
Stories 1
Heated Area (Sqft) 1895
Total Area (Sqft) 2707
Building Height 24
Building Code Construction Type V
Building Code Element B
Building Code Occupancy Types Residential
Occupancy Use Title single family dwelling
Building Code Edition 2023 Florida Building Code 8th Edition and 2020 National Electrical Code
Septic# (00-0000) or (X00-000) 23-0126
Sealed roof decking options. (Must select one option per FBC 2023 8th Edition) two layers of felt underlayment comply ASTM 0226 Type II or ASTM D4869 Type Ill or IV, or two layers of a synthetic underlayment meeting the performance requirements specified, lapped and fastened as specified.
Service Amps 200
Review Notes
1/4/2024 Application pending.
1/4/2024 Application submitted by applicant.
1/11/2024 Point Review - Printed-Online Application NEEDED
1/17/2024 Plan Review - Documents Required NEEDED ** ALL PLANS, ENGINEERING, ENERGY FORMS MUST COMPLY WITH 2023 FBC AND 2017 NEc.
1/22/2024 Plan Review - On Hold-Incomplete NEEDED ** ALL PLANS, ENGINEERING, ENERGY FORMS MUST COMPLY WITH 2023 FBC AND 2017 NEC.
1/29/2024 Plan Review - On Hold-Incomplete NEEDED ** ENERGY FORMS and manual j MUST COMPLY WITH 2023 FBC AND 2017 NEC.
1/31/2024 Plan Review - Building Approved
1/31/2024 Plan Review - Electrical Approved
1/31/2024 Plan Review - Mechanical Approved
1/31/2024 Plan Review - Plumbing Approved
1/31/2024 Plan Review - Fuel/Gas Approved
1/31/2024 Plan Review - Reviewed
2/16/2024 Zoning Review - Reviewed
2/16/2024 Final Review - Processing FINISHED FLOOR 94.50 PER PLAT
2/20/2024 Final Review - Payment Needed FINISHED FLOOR 94.50 PER PLAT
2/21/2024 Permit Issued Permit #000049256 created and approved.
3/8/2024 Final Review - Payment Needed FINISHED FLOOR 94.50 PER PLAT
7/18/2024 Final Review - Documents Required FINISHED FLOOR 94.50 PER PLAT EVERTON D RUDDOCK UPDATED LIABILITY
Contractors
Name/ Business License Title Role
Joann T Lev
Exceptions Realty Llc
Liability Insurance & Workers Comp Expired.
CRC1329719 Cert. Residential Contractor
Cody Barrs
Barrs Plumbing Inc
CFC1427145 Plumbing Contractor Subcontractor
Everton D Ruddock
D&s Lighting Inc
EC13003800 Electrical Contractor Subcontractor
Anthony R Franks
Lane Heating & Air Llc
CAC1818631 Cert. A/c Class “b” Subcontractor
Inspections
Inspection Notes Performed By Date
Passed: Engineering - Initial Driveway Smith, Blake 2/21/2024
Passed: Building - Footer Matt Forsyth 3/4/2024
Passed: Engineering - Setbacks Matt Forsyth 3/4/2024
Passed: Electrical - Temporary Service Matt Forsyth 3/4/2024
Release to power company Matt Forsyth 3/4/2024
Passed: Plumbing/Gas - 1st Underground Rough–In Matt Forsyth 4/22/2024
Passed: Building - Slab Electrical Conduit Under The Slab Inspected Also Matt Forsyth 5/8/2024
Passed: Building - Framing Matt Forsyth 7/24/2024
Passed: Building - Roof Decking Matt Forsyth 7/24/2024
Passed: Building - Wall Sheathing Matt Forsyth 7/24/2024
Passed: Electrical - 2nd Rough-In Matt Forsyth 8/6/2024
Passed: Mechanical - Rough In Matt Forsyth 8/6/2024
Passed: Plumbing/Gas - 2nd Rough-In Matt Forsyth 8/6/2024
Passed: Plumbing/Gas - Tub Set/Shower Pan Tub Water Tested For Leaks Matt Forsyth 8/6/2024
Passed: Building - Insulation Matt Forsyth 8/16/2024
Septic Release Inspection Health Dept 9/20/2024
Passed: Electrical - Permanent Power Matt Forsyth 2/14/2025
Release to power company Matt Forsyth 2/14/2025
Passed: Engineering - Final Driveway Beach, Garrett 2/21/2025
Passed: Building - Final Co Pending Cannot Closed Permit Or Release Certificate Of Occupancy Due To Missing Required Documents. Matt Forsyth 3/6/2025
Documents
File Name Date File Size
Q1lzpiiw.a5l.pdf 2025.07.14 1.17MB
Power Release-electrical-permanent Power 20250214.pdf 2025.07.05 11.41kB
Certificate Of Occupancy 20250307.pdf 2025.07.05 176.36kB
Owner And Contractor Signature Page 20240109 175324.pdf 2025.07.04 893.43kB
Original Permit 20240221.pdf 2025.06.22 38.96kB
Recorded Deed 20240104 171651.pdf 2025.06.22 151.98kB
911 Address Form 20240104 172703.pdf 2025.06.22 217.46kB
Site Plan With Lidar 63790 2024-02-16 13.49.23.601.pdf 2025.06.22 295.07kB
Energy Code Forms 20240104 173148.pdf 2025.06.22 401.53kB
Manual J Forms 20240104 173148.pdf 2025.06.22 401.53kB
Energy Code Forms 20240115 150803.pdf 2025.06.22 402.01kB
Confirmed Make Up Air For Blower Door Test. 49256 2025-03-07 08.03.13.704.pdf 2025.06.22 186.15kB
Product Approval Code Specifications Form 20240104 173149.pdf 2025.06.22 559.24kB
Site Plan 20240110 151735.pdf 2025.06.22 253.63kB
Architectural Plans 20240104 172703.pdf 2025.06.21 843.88kB
Architectural Plans 20240124 123431.pdf 2025.06.21 844.35kB
Reviewed Architectural Plans 63790 2024-01-31 09.19.53.207.pdf 2025.06.21 877.46kB
Subcontractor Form 20240104 173648.pdf 2025.06.21 495.20kB
Recorded Notice Of Commencement 20240104 173150.pdf 2025.06.21 559.78kB
Surveyor Letter Giving The Finished Floor Elevation 20240529 111614.pdf 2025.06.21 788.43kB
Property Appraiser Parcel Details Printed Page 20240104 173149.pdf 2025.06.20 1.10MB
Architectural Plans 20240104 172738.pdf 2025.06.20 3.47MB
Win_20240508_10_38_53_pro 2024-05-08 10.39.23.459.jpg 2025.06.20 115.75kB
Reviewed Structural Engineering 63790 2024-01-29 08.47.38.646.pdf 2025.06.20 3.35MB
Residential Or Commercial Checklist 20240104 173151.pdf 2025.06.20 1.28MB
Termite Certificate_final 20250228 141406v1.pdf 2025.06.19 468.50kB
Owner And Contractor Signature Page 20240104 171646.pdf 2025.06.19 2.22MB
Blower Door Test Results 20250304 075111v1.pdf 2025.03.04 793.91kB
Calcs Revised - Lot 3 Ko_2023 Fbc.pdf 2024.03.08 343.14kB
Power Release-electrical-temporary Service 20240304.pdf 2024.03.04 38.89kB
Reviewed Manual J 63790 2024-01-31 09.18.35.551.pdf 2024.01.31 936.56kB
Reviewed Energy Forms 63790 2024-01-31 09.18.35.973.pdf 2024.01.31 1.45MB
Energy Code Forms 20240130 090923.pdf 2024.01.30 2.11MB
Subcontractor Form 20240110 075029.pdf 2024.01.10 122.88kB
Site Plan 20240104 173153.pdf 2024.01.04 45.10kB
Septic Approval Paperwork 20240104 173152.pdf 2024.01.04 1,017.22kB