Permit Details

Permit Search

Permit

Mobile Home

185 SW MADEWOOD DR
LAKE CITY, FL 32024

Permit #
000049119
Application #
63769
Status Completed
  1. Submitted Jan 3, 2024
  2. Issued Jan 30, 2024
  3. Expires Sep 16, 2024
  4. Completed Mar 22, 2024

Property

Parcel #
03265-111
Owner
Humanes Paul E, Humanes Susan A
Acres
5.01
Subdivision
Mauldin Woodlands Phase 1
Zoning
A-3
Flood zone
X
District
2

Permit

Status
Completed
Septic release
Released
Related permit
—

Job Details

Elevation regulation
Minimum Requirement
Finished floor requirement
One foot above the road
Fema map number
12023C0380C
Mobile Home is a:
Double Wide
Year Built
2024
Width (Ft.In)
24
Length (Ft.In)
40
Driveway access to home:
Culvert Permit
Installation Decal #
108453
Septic #
24-0009
Setbacks Front
30'
Setback Side 1
25'
Setbacks Rear
25'
Dev Permit #
F023-
Setback Side 2
25'
Are you applying for a 5 year temporary permit?
No
Serial #
JAC FL 001984AB
Wind Zone?
2
Residential or Commercial Use?
Residential
Service Amps
200

Status & Review History

  1. Application pending.
  2. Application submitted by applicant.
  3. Point Review - Printed-Online Application
  4. Plan Review - Reviewed
  5. Zoning Review - Reviewed
  6. Final Review - Reviewed
  7. Final Review - Payment Needed
  8. Permit Issued

Contractors

  • Rusty L Knowles

    Floridas Finest Mobile Home Set Up

    License
    IH1038219
    Title
    Mh Installer (ih)
    Role
    Contractor
  • Glenn Whittington

    Whittington Electric Inc

    License
    EC13002957
    Title
    Electrical Contractor
    Role
    Subcontractor
  • Michael A Boland

    Ace A/c Of Ocala Llc

    License
    CAC1817716
    Title
    Cert Class B A/c
    Role
    Subcontractor

Inspections

  1. Mar 20, 2024

    Passed: Mobile Home - Mobile Home Set-Up Final

    Gasket Material Installed In Between The Two Halves Confirmed Need Septic Release To Complete Permit And Release Power

    Inspected by Matt Forsyth

  2. Mar 20, 2024

    Passed: Engineering - Setbacks

    Inspected by Matt Forsyth

  3. Mar 22, 2024

    Release to power company

    Inspected by Melissa Garber

  4. Mar 22, 2024

    Certificate-Release Certificate

    Inspected by Matt Forsyth

  5. Mar 22, 2024

    Septic Release Inspection

    Inspected by Health Dept